Assessment of microbial and level of Cadmium, Chromium and Lead contamination on drinking water refilling station in Bungus Teluk Kabung, West Sumatera, Indonesia

Azimatur Rahmi, Rahma Yulia, Asmaul Husna, Amelia Amir
{"title":"Assessment of microbial and level of Cadmium, Chromium and Lead contamination on drinking water refilling station in Bungus Teluk Kabung, West Sumatera, Indonesia","authors":"Azimatur Rahmi, Rahma Yulia, Asmaul Husna, Amelia Amir","doi":"10.13171/MJC02106041571AA","DOIUrl":null,"url":null,"abstract":"Refill drinking water is a choice of drinking water, especially for the middle-income community due to the convenience and affordable price. Many studies in Indonesia reported that drinking water from drinking water refilling stations is less safe or contaminated by coliform. This study assessed the microbial and level of several heavy metals (Cadmium, chromium, and Lead) contamination on refill drinking water from drinking water refilling station in Bungus Teluk Kabung West Sumatera, Indonesia. It found that Cadmium, Chromium, and Lead were detected in all samples. Still, none of their levels exceed the maximum permissible limits based on the guideline value on Ministry of Health Republic of Indonesia number 492/MENKES/PER/IV/2010. Lead was found as the highest amount in sample B and then Chromium in sample A with values of 0.367 ppb and 0.143 ppb. The microbial contamination presence in all three refill drinking water samples with the total coliform was 28, 15, and 240 MPN per 100 ml for samples A, B, and C. Sample C has the highest microbial risk compare to A and B. The presence of E. Coli was also confirmed for all samples, and the metallic sheen identified it in all culture samples. Because the standard of the microbial parameter must be zero for coliform and E. Coli, these results revealed that all three refill drinking water samples from drinking water refilling stations Bungus Teluk Kabung are not eligible for direct consumption and could harm human health. The proper water treatment process or change in raw water sources need to be considered in the future. Inspection and monitoring from the health authority should be scheduled regularly to protect the consumers.","PeriodicalId":18513,"journal":{"name":"Mediterranean Journal of Chemistry","volume":"29 1","pages":"201-206"},"PeriodicalIF":0.0000,"publicationDate":"2021-06-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Mediterranean Journal of Chemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.13171/MJC02106041571AA","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Refill drinking water is a choice of drinking water, especially for the middle-income community due to the convenience and affordable price. Many studies in Indonesia reported that drinking water from drinking water refilling stations is less safe or contaminated by coliform. This study assessed the microbial and level of several heavy metals (Cadmium, chromium, and Lead) contamination on refill drinking water from drinking water refilling station in Bungus Teluk Kabung West Sumatera, Indonesia. It found that Cadmium, Chromium, and Lead were detected in all samples. Still, none of their levels exceed the maximum permissible limits based on the guideline value on Ministry of Health Republic of Indonesia number 492/MENKES/PER/IV/2010. Lead was found as the highest amount in sample B and then Chromium in sample A with values of 0.367 ppb and 0.143 ppb. The microbial contamination presence in all three refill drinking water samples with the total coliform was 28, 15, and 240 MPN per 100 ml for samples A, B, and C. Sample C has the highest microbial risk compare to A and B. The presence of E. Coli was also confirmed for all samples, and the metallic sheen identified it in all culture samples. Because the standard of the microbial parameter must be zero for coliform and E. Coli, these results revealed that all three refill drinking water samples from drinking water refilling stations Bungus Teluk Kabung are not eligible for direct consumption and could harm human health. The proper water treatment process or change in raw water sources need to be considered in the future. Inspection and monitoring from the health authority should be scheduled regularly to protect the consumers.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
印尼西苏门答腊邦古斯特鲁克加邦饮用水补给站的微生物及镉、铬、铅污染水平评估
补充饮用水是饮用水的一种选择,由于方便和实惠的价格,尤其适合中等收入社区。印度尼西亚的许多研究报告说,饮用水补给站的饮用水不太安全或受到大肠菌群的污染。本研究评估了印尼西苏门答腊邦古斯特鲁克加邦饮用水补给站补给饮用水中几种重金属(镉、铬和铅)污染的微生物和水平。调查发现,所有样品中都检测到镉、铬和铅。尽管如此,它们的含量都没有超过基于印度尼西亚共和国卫生部第492/MENKES/PER/IV/2010号指导值的最大允许限值。B样品中铅含量最高,A样品中铬含量次之,分别为0.367 ppb和0.143 ppb。样品A、B和C的总大肠菌群分别为28、15和240 MPN / 100 ml,样品C的微生物污染风险最高,与A和B相比。所有样品均证实存在大肠杆菌,所有培养样品均有金属发光。由于大肠菌群和大肠杆菌的微生物参数标准必须为零,这些结果表明,从邦古斯特卢克加邦饮用水补充站获得的三个补充饮用水样本都不符合直接饮用的条件,可能危害人体健康。未来需要考虑适当的水处理工艺或改变原水来源。应定期安排卫生当局的检查和监测,以保护消费者。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Solid-Phase Separation and Green Removal of Amprolium Hydrochloride Veterinary Drug from Aqueous Media Using Dolomiaea Costus Roots as New Biosorbent Synthesis and Crystal Structure of Novel [(u-OCH6) (u-Cl) bis-[(bipy) (Cl)Cu(II)]]Complex In search of cytotoxic abietyl amides Crystal Structure and DFT Computations of a Solid-State Solution of Mixed Mononuclear Cu(II)/Co(II) Complex Influence of the activation method on the activity of the nickel catalyst
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1