Investigating mean room surface exitance values for office lighting

IF 2.1 3区 工程技术 Q2 CONSTRUCTION & BUILDING TECHNOLOGY Lighting Research & Technology Pub Date : 2022-11-01 DOI:10.1177/14771535211044665
A. Durante, K. Kelly
{"title":"Investigating mean room surface exitance values for office lighting","authors":"A. Durante, K. Kelly","doi":"10.1177/14771535211044665","DOIUrl":null,"url":null,"abstract":"Mean room surface exitance (MRSE) is a metric proposed to assess lighting quantity within a new design methodology focused on ambient and target illumination. This research builds upon findings from previous research examining the suitability of MRSE as a metric for assessing ambient illumination brightness levels and illumination adequacy for offices. An experiment was conducted to investigate a finding from previous studies that a linear relationship existed between perceived adequacy of illumination (PAI) and MRSE. It was found that the relationship diverges from linear once the scale of MRSE values is extended above the 100 lm/m2. This study also suggests a relationship between spatial brightness and MRSE for an extended range of MRSE values up to 1400 lm/m2. The findings from this research provide insight into a tentative range of MRSE levels that may be suitable for an office environment.","PeriodicalId":18133,"journal":{"name":"Lighting Research & Technology","volume":null,"pages":null},"PeriodicalIF":2.1000,"publicationDate":"2022-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Lighting Research & Technology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/14771535211044665","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 3

Abstract

Mean room surface exitance (MRSE) is a metric proposed to assess lighting quantity within a new design methodology focused on ambient and target illumination. This research builds upon findings from previous research examining the suitability of MRSE as a metric for assessing ambient illumination brightness levels and illumination adequacy for offices. An experiment was conducted to investigate a finding from previous studies that a linear relationship existed between perceived adequacy of illumination (PAI) and MRSE. It was found that the relationship diverges from linear once the scale of MRSE values is extended above the 100 lm/m2. This study also suggests a relationship between spatial brightness and MRSE for an extended range of MRSE values up to 1400 lm/m2. The findings from this research provide insight into a tentative range of MRSE levels that may be suitable for an office environment.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
调查办公室照明的平均房间表面出口值
平均房间表面出口(MRSE)是一种新的设计方法,用于评估环境和目标照明的照明数量。这项研究建立在先前的研究结果的基础上,研究了MRSE作为评估办公室环境照明亮度水平和照明充足性的指标的适用性。我们进行了一项实验来调查先前研究的发现,即感知照明充足性(PAI)与MRSE之间存在线性关系。当MRSE值的尺度扩大到100 lm/m2以上时,两者之间的关系就脱离了线性关系。该研究还提出了空间亮度与MRSE之间的关系,MRSE值的扩展范围达到1400 lm/m2。这项研究的结果提供了一个暂定的MRSE水平范围,它可能适用于办公环境。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Lighting Research & Technology
Lighting Research & Technology 工程技术-光学
CiteScore
5.40
自引率
16.00%
发文量
69
审稿时长
>12 weeks
期刊介绍: Lighting Research & Technology (LR&T) publishes original peer-reviewed research on all aspects of light and lighting and is published in association with The Society of Light and Lighting. LR&T covers the human response to light, the science of light generation, light control and measurement plus lighting design for both interior and exterior environments, as well as daylighting, energy efficiency and sustainability
期刊最新文献
Design, analysis and validation of Customised Homocentric Fresnel Collector based on longest wavelength of visible spectrum Visual and non-visual responses of drivers to simulated LED headlights varying in correlated colour temperature Life cycle cost analysis of LED retrofit and luminaire replacements for four-foot T8 troffers Editorial: Special issue for early career researchers in lighting Opinion: How to foster a motivating ecosystem for our next generation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1