Heating Mechanism of Double Tubular Steel Columns Part 2 Numerical Analysis and Comparison with the Experimental Results

T. Wakamatsu, Seiji Okinaga, M. Mizuno, T. Wakamatsu
{"title":"Heating Mechanism of Double Tubular Steel Columns Part 2 Numerical Analysis and Comparison with the Experimental Results","authors":"T. Wakamatsu, Seiji Okinaga, M. Mizuno, T. Wakamatsu","doi":"10.3210/FST.26.321","DOIUrl":null,"url":null,"abstract":"As shown in Figure 1, the initial condition of the method was that the heating temperature T0 (fire room) was 20°C and the temperatures of the gaps inside the steel tubes (T3 and T6 ) were 20°C. The coefficients of heat transfer H1 , H2 , H3 , H4 and H5 (W/m2K) were given as follows. Here, H1 , H2 , H3 and H4 were the coefficients of heat transfer for the external surface of the outside steel tube, the internal surface of the outside steel tube, the external surface of the inside steel tube and the internal surface of the inside steel tube respectively. And H5 was the coefficients of radiative heat transfer between the internal surface of the outside steel tube and the external surface of the internal surface of the inside steel tube.","PeriodicalId":12289,"journal":{"name":"Fire Science and Technology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2007-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fire Science and Technology","FirstCategoryId":"1087","ListUrlMain":"https://doi.org/10.3210/FST.26.321","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

As shown in Figure 1, the initial condition of the method was that the heating temperature T0 (fire room) was 20°C and the temperatures of the gaps inside the steel tubes (T3 and T6 ) were 20°C. The coefficients of heat transfer H1 , H2 , H3 , H4 and H5 (W/m2K) were given as follows. Here, H1 , H2 , H3 and H4 were the coefficients of heat transfer for the external surface of the outside steel tube, the internal surface of the outside steel tube, the external surface of the inside steel tube and the internal surface of the inside steel tube respectively. And H5 was the coefficients of radiative heat transfer between the internal surface of the outside steel tube and the external surface of the internal surface of the inside steel tube.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
双钢管柱加热机理第二部分:数值分析及与试验结果的比较
如图1所示,该方法的初始条件为加热温度T0(消防室)为20℃,钢管内部空隙(T3和T6)温度为20℃。换热系数H1、H2、H3、H4、H5 (W/m2K)分别为:式中,H1、H2、H3、H4分别为外钢管外表面、外钢管内表面、内钢管内表面的换热系数。H5为外钢管内表面与内钢管内表面的外表面之间的辐射换热系数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Chemical Fires Associated with Two Major Earthquakes in Japan Flame Retardant Waterborne Polyurethanes: Related Analytical Measurements The Early History of the Cone Calorimeter Modeling of Creep Behavior of High Strength Steel H-SA700 Columns at Elevated Temperature Analysis of Texts of Fire Accidents in University Chemistry Experiments Using AI Text Mining
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1