Rationale for the Choice of the Ellipsoidal Reflector Parameters for Biomedical Photometers

IF 0.2 Q4 INSTRUMENTS & INSTRUMENTATION Devices and Methods of Measurements Pub Date : 2021-12-22 DOI:10.21122/2220-9506-2021-12-4-259-271
N. Bezuglaya, A. A. Haponiuk, D. Bondariev, S. Poluectov, V. Chornyi, M. Bezuglyi
{"title":"Rationale for the Choice of the Ellipsoidal Reflector Parameters for Biomedical Photometers","authors":"N. Bezuglaya, A. A. Haponiuk, D. Bondariev, S. Poluectov, V. Chornyi, M. Bezuglyi","doi":"10.21122/2220-9506-2021-12-4-259-271","DOIUrl":null,"url":null,"abstract":"Biomedical photometersʼ information-measuring systems with ellipsoidal reflectors have acceptable results in determining of biological tissues optical properties in the visible and near-infrared spectral range. These photometers make it possible to study the optical radiation propagation in turbid media for direct and inverse problems of light-scattering optics. The purpose of this work is to study the influence of the ellipsoidal reflectors design parameters on the results of biomedical photometry when simulating the optical radiation propagation in a system of biological tissue and reflectors in transmitted and reflected light.The paper substantiates the choice of the ellipsoidal reflectors’ focal parameter for efficient registration of forward and backscattered light. The methodology of the process is illustrated by the results of a model experiment using the Monte Carlo simulation for samples of human brain white and gray matter at the visible range of 405 nm, 532 nm, and 650 nm. The total transmittance, diffuse reflectance, and absorption graphs depending on the sample thickness were obtained. Based on the introduced concepts of the ellipsoidal reflector efficiency index and its efficiency factor, the expediency of choosing the ellipsoidal reflectors focal parameter is analyzed to ensure the registration of the maximum amount of scattered light. The graphs of efficiency index in reflected and transmitted light for different thickness samples of white and gray matter and efficiency factors depending on the sample thickness were obtained.The influence of the reflectors ellipticity on the illuminance of various zones of photometric images using the example of an absorbing biological medium – pig liver tissue – at wavelength of 405 nm with a Monte Carlo simulation was analyzed.The optical properties of biological media (scattering and absorption coefficients, scattering anisotropy factor, refractive index) and the samples’ geometric dimensions, particularly the thickness, are predetermined when choosing the ellipsoidal reflectors parameters for registration of the scattered light. Coordinates of the output of photons and their statistical weight obtained in the Monte Carlo simulation of light propagation in biological tissue have a physical effect on a characteristic scattering spot formation in the receiving plane of a biomedical photometer with ellipsoidal reflectors.","PeriodicalId":41798,"journal":{"name":"Devices and Methods of Measurements","volume":"2 1","pages":""},"PeriodicalIF":0.2000,"publicationDate":"2021-12-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Devices and Methods of Measurements","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21122/2220-9506-2021-12-4-259-271","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 1

Abstract

Biomedical photometersʼ information-measuring systems with ellipsoidal reflectors have acceptable results in determining of biological tissues optical properties in the visible and near-infrared spectral range. These photometers make it possible to study the optical radiation propagation in turbid media for direct and inverse problems of light-scattering optics. The purpose of this work is to study the influence of the ellipsoidal reflectors design parameters on the results of biomedical photometry when simulating the optical radiation propagation in a system of biological tissue and reflectors in transmitted and reflected light.The paper substantiates the choice of the ellipsoidal reflectors’ focal parameter for efficient registration of forward and backscattered light. The methodology of the process is illustrated by the results of a model experiment using the Monte Carlo simulation for samples of human brain white and gray matter at the visible range of 405 nm, 532 nm, and 650 nm. The total transmittance, diffuse reflectance, and absorption graphs depending on the sample thickness were obtained. Based on the introduced concepts of the ellipsoidal reflector efficiency index and its efficiency factor, the expediency of choosing the ellipsoidal reflectors focal parameter is analyzed to ensure the registration of the maximum amount of scattered light. The graphs of efficiency index in reflected and transmitted light for different thickness samples of white and gray matter and efficiency factors depending on the sample thickness were obtained.The influence of the reflectors ellipticity on the illuminance of various zones of photometric images using the example of an absorbing biological medium – pig liver tissue – at wavelength of 405 nm with a Monte Carlo simulation was analyzed.The optical properties of biological media (scattering and absorption coefficients, scattering anisotropy factor, refractive index) and the samples’ geometric dimensions, particularly the thickness, are predetermined when choosing the ellipsoidal reflectors parameters for registration of the scattered light. Coordinates of the output of photons and their statistical weight obtained in the Monte Carlo simulation of light propagation in biological tissue have a physical effect on a characteristic scattering spot formation in the receiving plane of a biomedical photometer with ellipsoidal reflectors.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
生物医学光度计椭球面反射器参数选择的基本原理
具有椭球反射器的生物医学光度计信息测量系统在测定可见光和近红外光谱范围内的生物组织光学特性方面具有可接受的结果。这些光度计使光散射光学的正反问题研究光辐射在浑浊介质中的传播成为可能。本工作的目的是研究椭球面反射器设计参数对生物医学测光结果的影响,以模拟光辐射在生物组织和反射器组成的系统中的传播。本文对椭球面反射镜的焦点参数选择进行了实证研究,以实现前散射光和后散射光的有效配准。在405nm、532nm和650nm可见光范围内,用蒙特卡罗模拟人脑白质和灰质样品的模型实验结果说明了这一过程的方法。得到了随样品厚度变化的总透射率、漫反射和吸收曲线。在介绍椭球面反射镜效率指数及其效率因子概念的基础上,分析了椭球面反射镜焦距参数选择的方便性,以保证最大散射光量的配准。得到了不同厚度白质和灰质样品的反射光和透射光效率指数曲线图以及随样品厚度变化的效率系数。以吸收生物介质猪肝组织为例,利用蒙特卡罗模拟分析了反射器椭圆度对光度图像各区域照度的影响。生物介质的光学性质(散射和吸收系数、散射各向异性系数、折射率)和样品的几何尺寸,特别是厚度,在选择用于配准散射光的椭球反射器参数时是预先确定的。光在生物组织中传播的蒙特卡罗模拟中得到的光子输出坐标及其统计权值对椭球面反射体生物医学光度计接收面上的特征散射斑形成有物理影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Devices and Methods of Measurements
Devices and Methods of Measurements INSTRUMENTS & INSTRUMENTATION-
自引率
25.00%
发文量
18
审稿时长
8 weeks
期刊最新文献
Use of the Laser Beam Deflection Technique for Thermo-Optic Coefficients Study in Gadolinium-Yttrium Oxyorthosilicate Doped with Erbium Ions Electronic Shooting Simulator Family "STrIzh": Implementation Levels and Free Software Structure Optimal Printing and Post-Processing Modes of Polymer Products Manufactured Using SLA-Technology of Additive Мanufacturing Influence of Temperature from 20 to 100 °C on Specific Surface Energy and Fracture Toughness of Silicon Wafers Tin Oxide Modification of Indium Oxide Gas Sensitive Layers to Increase Efficiency of Gas Sensors
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1