Analysis of Waveform of Partial Discharge in Air Insulation Measured by RC Detector

Michael Stevano Sinurat, U. Khayam
{"title":"Analysis of Waveform of Partial Discharge in Air Insulation Measured by RC Detector","authors":"Michael Stevano Sinurat, U. Khayam","doi":"10.1109/EECSI.2018.8752790","DOIUrl":null,"url":null,"abstract":"This study discusses the measurement of Partial Discharge (PD) in air insulation. Partial Discharge Measurement is very important to know the condition of electrical equipment. The cause of partial discharge is not only old equipment, but also from set-up errors and insulation problems. In this research partial discharge measurement was performed by using electrical methods. Electrical method use RC Detector. The modeling of partial discharge was done by using needle-plane electrode distant 1 cm in air insulation. Partial discharge measurement parameters include the measurement of Background Noise (BGN), Partial Discharge Inception Voltage (PDIV) and PD Waveform. The Partial Discharge measurement result show that Vpp of BGN ON is higher than Vpp of BGN OFF. The negative PDIV signal first appeared for the RC Detector at a voltage 3.55 KV and Positive PDIV at 4.01 KV. Negative and positive PD waveform for RC Detector at 5 KV, 5.5 KV, 6 KV, 6.5 KV and 7 KV respectively, it has been found that the fall time is greater than the rise time, and peak to peak voltage (Vpp) will be greater when the applied voltage is greater.","PeriodicalId":6543,"journal":{"name":"2018 5th International Conference on Electrical Engineering, Computer Science and Informatics (EECSI)","volume":"39 1","pages":"367-372"},"PeriodicalIF":0.0000,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 5th International Conference on Electrical Engineering, Computer Science and Informatics (EECSI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EECSI.2018.8752790","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

This study discusses the measurement of Partial Discharge (PD) in air insulation. Partial Discharge Measurement is very important to know the condition of electrical equipment. The cause of partial discharge is not only old equipment, but also from set-up errors and insulation problems. In this research partial discharge measurement was performed by using electrical methods. Electrical method use RC Detector. The modeling of partial discharge was done by using needle-plane electrode distant 1 cm in air insulation. Partial discharge measurement parameters include the measurement of Background Noise (BGN), Partial Discharge Inception Voltage (PDIV) and PD Waveform. The Partial Discharge measurement result show that Vpp of BGN ON is higher than Vpp of BGN OFF. The negative PDIV signal first appeared for the RC Detector at a voltage 3.55 KV and Positive PDIV at 4.01 KV. Negative and positive PD waveform for RC Detector at 5 KV, 5.5 KV, 6 KV, 6.5 KV and 7 KV respectively, it has been found that the fall time is greater than the rise time, and peak to peak voltage (Vpp) will be greater when the applied voltage is greater.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
RC检测仪测量空气绝缘局部放电波形分析
本文讨论了空气绝缘中局部放电的测量方法。局部放电测量是了解电气设备运行状况的重要手段。局部放电的原因不仅是设备陈旧,还有设置错误和绝缘问题。本研究采用电学方法进行局部放电测量。电法采用RC检测器。在空气绝缘中采用距离为1cm的针面电极进行局部放电模拟。局部放电测量参数包括背景噪声(BGN)、局部放电起始电压(PDIV)和局部放电波形的测量。局部放电测量结果表明,BGN ON的Vpp高于BGN OFF的Vpp。RC检测器在电压为3.55 KV时首先出现负PDIV信号,在电压为4.01 KV时出现正PDIV信号。分别在5 KV、5.5 KV、6 KV、6.5 KV和7 KV时RC检测器的负、正PD波形,发现其下降时间大于上升时间,且施加电压越大,峰值电压(Vpp)越大。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Design of Low Noise Micro Liter Syringe Pump for Quartz Crystal Microbalance Sensor Development of Mobile Based Educational Game as a Learning Media for Basic Programming in VHS Sentiment Analysis Based on Appraisal Theory for Assessing Incumbent Electability Variance and Symmetrical-based Approach for Optimal Alignment of 3D Model Comparison of LFC Optimization on Micro-hydro using PID, CES, and SMES based Firefly Algorithm
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1