E. Escalante, José David Henao Casas, Carlos Moreno de Guerra Per, María Dolores Maza Vera, Carles Moreno Valverde
{"title":"Unintentional Recharge of Aquifers from Small Dams and Dykes in Spain: A GIS-Based Approach to Determine a Fractional Volume","authors":"E. Escalante, José David Henao Casas, Carlos Moreno de Guerra Per, María Dolores Maza Vera, Carles Moreno Valverde","doi":"10.3390/earth4030031","DOIUrl":null,"url":null,"abstract":"Conducting an accurate hydrological water balance at the regional and country-wide scales is paramount to assessing available water resources and adequately allocating them. One of the main components of these balances is the anthropogenic recharge of groundwater either intentionally, through managed aquifer recharge (MAR), or unintentionally, where infiltration from dams and dykes can play a significant role. In Spain, proper management of water resources is critical due to the arid to semiarid conditions prevalent in most of the territory and the relevance of water resources for maintaining a robust agricultural sector. Previous work estimated country-wide recharge from MAR at 150 to 280 Mm3/year. Recently, water authorities pointed out that, according to hydrological water balances, the total unintentional recharge volume from water courses may exceed 500 Mm3/year. The present research aims to present a new inventory of transverse structures (also referred to as small dams and dykes) in Spain and use it to estimate country-wide unintentional recharge. The inventory, compiled by the Spanish Ministry for the Ecological Transition and the Demographic Challenge, has 27,680 structures and includes construction and impoundment characteristics, which allow for estimating the wet perimeter and the infiltration area. To this end, structural data from the inventory were crossed through map algebra in a GIS environment with thematic layers, such as lithology, permeability, the digital elevation model, the transverse structures’ wetted area, the average groundwater levels, and a clogging correction factor. Two analytical formulas to compute infiltration from small dams and dykes were tested. The resulting volume of unintentional recharge from transverse structures ranges between 812.5 and 2716.6 Mm3/year. The comparison against regional and national water balances suggests that the lowest value of the range (i.e., 812.5 Mm3/year) is probably the most realistic. Anthropogenic recharge from MAR and transverse structures is likely in the range of 1012.5–1514.8 Mm3/year. This rough figure can help close the hydrological balance at the national and river basin levels and contribute to calibrating regional models. Furthermore, they provide an order of magnitude for anthropogenic recharge at a national scale, which is difficult to obtain.","PeriodicalId":51020,"journal":{"name":"Earth Interactions","volume":"18 1","pages":""},"PeriodicalIF":1.6000,"publicationDate":"2023-08-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Earth Interactions","FirstCategoryId":"89","ListUrlMain":"https://doi.org/10.3390/earth4030031","RegionNum":4,"RegionCategory":"地球科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"GEOSCIENCES, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
Conducting an accurate hydrological water balance at the regional and country-wide scales is paramount to assessing available water resources and adequately allocating them. One of the main components of these balances is the anthropogenic recharge of groundwater either intentionally, through managed aquifer recharge (MAR), or unintentionally, where infiltration from dams and dykes can play a significant role. In Spain, proper management of water resources is critical due to the arid to semiarid conditions prevalent in most of the territory and the relevance of water resources for maintaining a robust agricultural sector. Previous work estimated country-wide recharge from MAR at 150 to 280 Mm3/year. Recently, water authorities pointed out that, according to hydrological water balances, the total unintentional recharge volume from water courses may exceed 500 Mm3/year. The present research aims to present a new inventory of transverse structures (also referred to as small dams and dykes) in Spain and use it to estimate country-wide unintentional recharge. The inventory, compiled by the Spanish Ministry for the Ecological Transition and the Demographic Challenge, has 27,680 structures and includes construction and impoundment characteristics, which allow for estimating the wet perimeter and the infiltration area. To this end, structural data from the inventory were crossed through map algebra in a GIS environment with thematic layers, such as lithology, permeability, the digital elevation model, the transverse structures’ wetted area, the average groundwater levels, and a clogging correction factor. Two analytical formulas to compute infiltration from small dams and dykes were tested. The resulting volume of unintentional recharge from transverse structures ranges between 812.5 and 2716.6 Mm3/year. The comparison against regional and national water balances suggests that the lowest value of the range (i.e., 812.5 Mm3/year) is probably the most realistic. Anthropogenic recharge from MAR and transverse structures is likely in the range of 1012.5–1514.8 Mm3/year. This rough figure can help close the hydrological balance at the national and river basin levels and contribute to calibrating regional models. Furthermore, they provide an order of magnitude for anthropogenic recharge at a national scale, which is difficult to obtain.
期刊介绍:
Publishes research on the interactions among the atmosphere, hydrosphere, biosphere, cryosphere, and lithosphere, including, but not limited to, research on human impacts, such as land cover change, irrigation, dams/reservoirs, urbanization, pollution, and landslides. Earth Interactions is a joint publication of the American Meteorological Society, American Geophysical Union, and American Association of Geographers.