Influence of Apical Patency, Coronal Preflaring and Calcium Hydroxide on the Accuracy of Root ZX Apex Locator for Working Length Determination: An In Vitro Study

IF 0.6 Q4 DENTISTRY, ORAL SURGERY & MEDICINE Journal of Advanced Oral Research Pub Date : 2021-09-06 DOI:10.1177/23202068211036139
Mostafa Godiny, Reza Hatam, R. Safari-Faramani, Atefeh Khavid, Mohammad Reza Rezaei
{"title":"Influence of Apical Patency, Coronal Preflaring and Calcium Hydroxide on the Accuracy of Root ZX Apex Locator for Working Length Determination: An In Vitro Study","authors":"Mostafa Godiny, Reza Hatam, R. Safari-Faramani, Atefeh Khavid, Mohammad Reza Rezaei","doi":"10.1177/23202068211036139","DOIUrl":null,"url":null,"abstract":"Aim: One of the main steps in a successful endodontic treatment is determining the correct working length (WL) of the root canal. In this regard, electronic apex locators (EAL) have been widely used for measuring the WL. The accuracy of EALs in determining the WL may be influenced by various factors. This study is aimed to evaluate the effects of apical patency, coronal preflaring, and calcium hydroxide on the accuracy of the EAL. Materials and Methods: In this in vitro study, 20 central incisor single-rooted human teeth with fully formed apex were considered. Then, samples were randomly divided into two study groups, ten samples in each group. The WL was determined and recorded at 0.5 mm distance to the apex using Root ZX apex locator before and after creating patency, coronal preflaring, and calcium hydroxide administration. All WLs were measured separately for each tooth and reviewed independently by two experienced operators with extensive experience in using EALs. Paired t test and Wilcoxon signed-rank test were applied and the significant level was at .05. Results: Statistical analysis of the obtained data showed a significant decline in the WL after apical patency and coronal preflaring (P < .05). Moreover, WL exhibited a significant enhancement after calcium hydroxide application (P < .05). Conclusion: Apical patency and coronal preflaring increased the accuracy of apex locators in determining the WL of the teeth. Besides, calcium hydroxide residues in the root canal reduced the accuracy of the apex locator.","PeriodicalId":43017,"journal":{"name":"Journal of Advanced Oral Research","volume":null,"pages":null},"PeriodicalIF":0.6000,"publicationDate":"2021-09-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Advanced Oral Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/23202068211036139","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 3

Abstract

Aim: One of the main steps in a successful endodontic treatment is determining the correct working length (WL) of the root canal. In this regard, electronic apex locators (EAL) have been widely used for measuring the WL. The accuracy of EALs in determining the WL may be influenced by various factors. This study is aimed to evaluate the effects of apical patency, coronal preflaring, and calcium hydroxide on the accuracy of the EAL. Materials and Methods: In this in vitro study, 20 central incisor single-rooted human teeth with fully formed apex were considered. Then, samples were randomly divided into two study groups, ten samples in each group. The WL was determined and recorded at 0.5 mm distance to the apex using Root ZX apex locator before and after creating patency, coronal preflaring, and calcium hydroxide administration. All WLs were measured separately for each tooth and reviewed independently by two experienced operators with extensive experience in using EALs. Paired t test and Wilcoxon signed-rank test were applied and the significant level was at .05. Results: Statistical analysis of the obtained data showed a significant decline in the WL after apical patency and coronal preflaring (P < .05). Moreover, WL exhibited a significant enhancement after calcium hydroxide application (P < .05). Conclusion: Apical patency and coronal preflaring increased the accuracy of apex locators in determining the WL of the teeth. Besides, calcium hydroxide residues in the root canal reduced the accuracy of the apex locator.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
根尖通畅、冠状面预扩和氢氧化钙对ZX根尖定位仪测定工作长度准确性的影响:体外研究
目的:根管治疗成功的主要步骤之一是确定根管的正确工作长度(WL)。在这方面,电子顶点定位器(EAL)已被广泛用于测量WL。EALs测定WL的准确性可能受到各种因素的影响。本研究旨在探讨根尖通畅、冠状面预扩及氢氧化钙对EAL准确度的影响。材料与方法:以20颗人中切牙单根尖牙为研究对象。然后,将样本随机分为两个研究组,每组10个样本。在建立通畅、冠状面预扩和氢氧化钙给药前后,使用根ZX根尖定位仪测定并记录距离根尖0.5 mm处的白度。所有的WLs分别测量每个牙齿,并由两名经验丰富的使用EALs的操作员独立审查。采用配对t检验和Wilcoxon符号秩检验,显著性水平为0.05。结果:经统计分析,经根尖开放和冠状面预扩后WL明显下降(P < 0.05)。氢氧化钙处理后WL明显增强(P < 0.05)。结论:根尖开放和冠状面预扩提高了根尖定位仪测定牙齿长宽的准确性。此外,根管内的氢氧化钙残留降低了根尖定位器的准确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Advanced Oral Research
Journal of Advanced Oral Research DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
1.10
自引率
0.00%
发文量
18
期刊最新文献
Microbiological and Immunological Assessment of Peri-implant Sites in Healthy and Diabetic Individuals After Prosthetic Rehabilitation: A Prospective Case Control Study Translucency and Color Difference of Monolithic Zirconia Restorations: The Effect of Surface Finishing on Background Color Effects of Fluoride Varnish on Roughness of Polyacid-Modified Composite Resins at Different Temperatures: An In Vitro Study Synthesis and Characterization of Zirconium Oxide Nanoparticles Based on Hemidesmus Indicus Extract: Evaluation of Biocompatibility and Bioactivity for Prosthetic Implant Coatings Comparative Evaluation of Penetrability of Various Bioceramic Sealers into the Tubules of Radicular Dentin
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1