Studies concerning the biomonitoring of the degree of environmental pollution using a urea-sensitive enzymatic sensor

Fiammetta Kormos, Adrienne Naumescu Lengauer
{"title":"Studies concerning the biomonitoring of the degree of environmental pollution using a urea-sensitive enzymatic sensor","authors":"Fiammetta Kormos,&nbsp;Adrienne Naumescu Lengauer","doi":"10.1002/(SICI)1098-2728(2000)12:1<27::AID-LRA5>3.0.CO;2-U","DOIUrl":null,"url":null,"abstract":"<p>The biosensor, which determines the variation of the pH as a consequence of the hydrolysis process of urea, is composed of a biological receiver (the urease) and a potentiometric sensor (a metallic pH electrode, tungsten). Keeping in mind that the sensitivity of the sensor changes depending with the inhibitor concentration for urease (which is present in the water or in the soil), this could be used to determine the degree of pollution of the surface waters and of the soil. In this way it would be possible to establish the quantities of the urea utilized as chemical fertilizer.</p><p>In the present work, we present the investigation of the inhibition effect of the ions Pb<sup>2+</sup>, Fe<sup>2+</sup>, Sn<sup>2+</sup>, Zn<sup>2+</sup> and Hg<sup>2+</sup> toward the urea-sensitive biosensor. The determinations with samples of surface waters and soils in the presence of 10<sup>−1</sup> M urea and one-minute contact time has demonstrated the possibility of monitoring the concentrations of these ions in the following domains: 10<sup>−2</sup>–10<sup>−6</sup> M Fe<sup>2+</sup>; 10<sup>−2</sup>–10<sup>−6</sup> M Zn<sup>2+</sup>; 10<sup>−4</sup>–10<sup>−6</sup> M Pb<sup>2+</sup>. These limiting values are found if the cation is individually present. © 2000 John Wiley &amp; Sons, Inc. Lab Robotics and Automation 12:27–30, 2000</p>","PeriodicalId":100863,"journal":{"name":"Laboratory Robotics and Automation","volume":"12 1","pages":"27-30"},"PeriodicalIF":0.0000,"publicationDate":"2000-02-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/(SICI)1098-2728(2000)12:1<27::AID-LRA5>3.0.CO;2-U","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Laboratory Robotics and Automation","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/%28SICI%291098-2728%282000%2912%3A1%3C27%3A%3AAID-LRA5%3E3.0.CO%3B2-U","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

Abstract

The biosensor, which determines the variation of the pH as a consequence of the hydrolysis process of urea, is composed of a biological receiver (the urease) and a potentiometric sensor (a metallic pH electrode, tungsten). Keeping in mind that the sensitivity of the sensor changes depending with the inhibitor concentration for urease (which is present in the water or in the soil), this could be used to determine the degree of pollution of the surface waters and of the soil. In this way it would be possible to establish the quantities of the urea utilized as chemical fertilizer.

In the present work, we present the investigation of the inhibition effect of the ions Pb2+, Fe2+, Sn2+, Zn2+ and Hg2+ toward the urea-sensitive biosensor. The determinations with samples of surface waters and soils in the presence of 10−1 M urea and one-minute contact time has demonstrated the possibility of monitoring the concentrations of these ions in the following domains: 10−2–10−6 M Fe2+; 10−2–10−6 M Zn2+; 10−4–10−6 M Pb2+. These limiting values are found if the cation is individually present. © 2000 John Wiley & Sons, Inc. Lab Robotics and Automation 12:27–30, 2000

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
脲敏感酶传感器对环境污染程度的生物监测研究
该生物传感器由生物接收器(脲酶)和电位传感器(金属pH电极,钨)组成,用于测定尿素水解过程中pH值的变化。请记住,传感器的灵敏度取决于脲酶抑制剂的浓度(存在于水中或土壤中),这可以用来确定地表水和土壤的污染程度。这样就有可能确定用作化肥的尿素的数量。在本工作中,我们研究了Pb2+、Fe2+、Sn2+、Zn2+和Hg2+离子对尿素敏感生物传感器的抑制作用。在10−1 M尿素和1分钟接触时间下对地表水和土壤样品的测定表明,可以在以下区域监测这些离子的浓度:10−2-10−6 M Fe2+;10−2-10−6 M Zn2+;10−4 ~ 10−6 M Pb2+。如果阳离子单独存在,就会发现这些极限值。©2000 John Wiley &儿子,Inc。实验室机器人与自动化,2000
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Flow system for calibration and interference examination in two-component analysis Development of hardware and software for on-line sample preparation using sequential-injection analysis Automation of procedures to measure ash content for polyolefin and ryton poly(phenylene sulfide) resins Spectrophotometric determination of phosphite in fertilizers in a flow injection system with online sample preparation Determination of trace amounts of copper using a flow-through spectrophotometric sensor
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1