Heat Pipe-Based DEMO Divertor Target Concept: High Heat Flux Performance Evaluation

IF 0.5 Q4 NUCLEAR SCIENCE & TECHNOLOGY Journal of Nuclear Engineering and Radiation Science Pub Date : 2023-03-09 DOI:10.3390/jne4010021
Weng Wen, B. Ghidersa, W. Hering, J. Starflinger, R. Stieglitz
{"title":"Heat Pipe-Based DEMO Divertor Target Concept: High Heat Flux Performance Evaluation","authors":"Weng Wen, B. Ghidersa, W. Hering, J. Starflinger, R. Stieglitz","doi":"10.3390/jne4010021","DOIUrl":null,"url":null,"abstract":"The use of heat pipes (HP) for the DEMO in-vessel plasma-facing components (PFCs) has been considered because of their high capacity to transport the heat from a heat source to a heat sink by means of the vaporization and condensation of the working fluid inside and their ability to enlarge the heat transfer area of the cooling circuit substantially. Recent engineering studies conducted in the framework of the EUROfusion work package Divertor (Wen et al, 2021) indicate that it is possible to design a heat pipe with a capillary limit above 6 kW using a composite capillary structure (wherein axial grooves cover the adiabatic zone and the condenser, and sintered porous material covers the evaporator). This power level would correspond to an applied heat flux of 20 MW/m2, rendering such a design interesting with respect to a divertor target concept. To validate the results of the initial engineering analysis, several experiments have been conducted to evaluate the actual performance of the proposed heat pipe concept. The present contribution presents the experiment’s results regarding the examination of the operating limits of two different designs for an evaporator: one featuring a plain porous structure, and one featuring ribs and channels.","PeriodicalId":16756,"journal":{"name":"Journal of Nuclear Engineering and Radiation Science","volume":"15 1","pages":""},"PeriodicalIF":0.5000,"publicationDate":"2023-03-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Nuclear Engineering and Radiation Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/jne4010021","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"NUCLEAR SCIENCE & TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

The use of heat pipes (HP) for the DEMO in-vessel plasma-facing components (PFCs) has been considered because of their high capacity to transport the heat from a heat source to a heat sink by means of the vaporization and condensation of the working fluid inside and their ability to enlarge the heat transfer area of the cooling circuit substantially. Recent engineering studies conducted in the framework of the EUROfusion work package Divertor (Wen et al, 2021) indicate that it is possible to design a heat pipe with a capillary limit above 6 kW using a composite capillary structure (wherein axial grooves cover the adiabatic zone and the condenser, and sintered porous material covers the evaporator). This power level would correspond to an applied heat flux of 20 MW/m2, rendering such a design interesting with respect to a divertor target concept. To validate the results of the initial engineering analysis, several experiments have been conducted to evaluate the actual performance of the proposed heat pipe concept. The present contribution presents the experiment’s results regarding the examination of the operating limits of two different designs for an evaporator: one featuring a plain porous structure, and one featuring ribs and channels.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于热管的DEMO导流器目标概念:高热流性能评估
由于热管能够通过内部工作流体的蒸发和冷凝将热量从热源输送到散热器,并且能够大大扩大冷却回路的传热面积,因此考虑了在DEMO容器内等离子体面组件(pfc)中使用热管(HP)。最近在EUROfusion工作包Divertor框架内进行的工程研究(Wen et al ., 2021)表明,可以使用复合毛细管结构(其中轴向槽覆盖绝热区和冷凝器,烧结多孔材料覆盖蒸发器)设计毛细管极限超过6 kW的热管。这一功率水平对应于20兆瓦/平方米的应用热流,使得这种设计在导流器目标概念方面很有趣。为了验证最初的工程分析结果,已经进行了几个实验来评估所提出的热管概念的实际性能。本文介绍了两种不同蒸发器设计的工作极限的实验结果:一种是平面多孔结构,另一种是肋和通道结构。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
1.30
自引率
0.00%
发文量
56
期刊介绍: The Journal of Nuclear Engineering and Radiation Science is ASME’s latest title within the energy sector. The publication is for specialists in the nuclear/power engineering areas of industry, academia, and government.
期刊最新文献
Verification and Geometry Optimization of a One Fluid Molten Salt Reactor (OFMSR) with Fixed Volume The Transfer of Xenon-135 to Molten Salt Reactor Graphite Molten Salt Pump Journal-Bearings Dynamic Characteristics Under Hydrodynamic Lubrication Conditions Technical Brief: Safeguardability Analysis of a Molten Salt Sampling System Design An Improved Heat Flux Partitioning Model of Nucleate Boiling Under Saturated Pool Boiling Condition
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1