{"title":"Switching transients during energizing capacitive load by a vacuum circuit breaker","authors":"Y. Fu, G. Damstra","doi":"10.1109/14.231549","DOIUrl":null,"url":null,"abstract":"Both experimental investigations and computer simulations of multiple prestrikes and associated prestriking overvoltages during energizing a capacitive load (capacitor bank or unloaded cable) by a vacuum circuit breaker are presented. It has been found that the prestriking overvoltage is associated with multiple prestrikes, and the circuit parameters or arrangements play important roles on the severity of the prestriking overvoltages. A simple computer simulation program is established and verified with the experimental results. Further simulations of several probable practical cases are also provided. Normally, overvoltages will not exceed 3 PU, but higher values are possible in special cases due to resonances in cable-line-cable networks. >","PeriodicalId":13105,"journal":{"name":"IEEE Transactions on Electrical Insulation","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1993-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"15","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Electrical Insulation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/14.231549","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15

Abstract

Both experimental investigations and computer simulations of multiple prestrikes and associated prestriking overvoltages during energizing a capacitive load (capacitor bank or unloaded cable) by a vacuum circuit breaker are presented. It has been found that the prestriking overvoltage is associated with multiple prestrikes, and the circuit parameters or arrangements play important roles on the severity of the prestriking overvoltages. A simple computer simulation program is established and verified with the experimental results. Further simulations of several probable practical cases are also provided. Normally, overvoltages will not exceed 3 PU, but higher values are possible in special cases due to resonances in cable-line-cable networks. >
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
真空断路器给容性负载通电时的开关瞬态
本文介绍了真空断路器给容性负载(电容器组或空电缆)通电过程中多次预击和相关预击过电压的实验研究和计算机模拟。研究发现,预击过电压与多次预击有关,电路参数或布置对预击过电压的严重程度有重要影响。建立了简单的计算机仿真程序,并与实验结果进行了验证。还提供了几个可能的实际情况的进一步模拟。正常情况下,过压不超过3pu,但在特殊情况下,由于电缆-电缆-电缆网络中的谐振,过压可能会更高。>
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The effect of the definition used in measuring partial discharge inception voltages Detection and location of internal defects in the insulation of power transformers The definitions used for partial discharge phenomena The relation between thermal and electrical stress and the PD behavior of epoxy-resin transformers Digital measurement of partial discharges in full-sized power capacitors
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1