Ilia Partch, J. Ferrell, D. Morrison, E. Salinas, S. Franks
{"title":"Quantifying Volume Expansion of Gas-Generating Materials in Cement Slurries","authors":"Ilia Partch, J. Ferrell, D. Morrison, E. Salinas, S. Franks","doi":"10.2118/193624-MS","DOIUrl":null,"url":null,"abstract":"\n In cementing applications, the release of gas is used to prevent shrinkage of the set cement in an annulus. With a significant decrease of volume of the wellbore, long term annular isolation may result in microfractures of the cement system; therefore, a failure of the cement bond (Go Boncan and Dillenbeck 2003). Currently, there is not a recommended procedure to quantitatively measure cement additives that facilitate gas expansion. This paper describes a methodical approach to quantify gas expansion within cement slurries.\n Traditionally, a known rudimentary technique in measuring gas expansion in cement slurries is to use a glass beaker and to record the observations. Under static and atmospheric conditions, a graduated cylinder has been used to quantitatively measure the displacement of gas release within the annulus at ambient conditions. The new method developed in this paper will demonstrate that gas was being expelled into the atmosphere when the cement slurry containing gas generating additives was tested under ambient conditions. The procedure developed here will demonstrate that gas was entrained within the cement matrix.\n An initial assessment of varying particle sizes of coated aluminum granules in a caustic solution showed that a consistent volume of gas was released. This working hypothesis was substantiated by measuring the volume of gas released within a closed system using a data logger. To ensure validation of this procedure, in-situ gas producing cement slurries were measured utilizing this method. With this experimental setup, quantifying the measurement of released gas from the cement matrix confirmed that variation of particle size does not affect performance.\n Gas volume displacement measurement using an inverted graduated cylinder was set up to quantitatively determine the volume of the released gas within the cement matrix with the utilization of a stir plate. The system utilized polytetrafluorethylene tubing to transport the released gas that was produced from the matrix to the inverted graduated cylinder that was filled with deionized water. The released gas volume was assessed by displacement.\n The enclosed dynamic apparatus with an inverted graduated cylinder was fitted with a paddle. This experimental setup enabled a homogenous blend and prevented void formation as the matrix was continuously agitated. This enclosed dynamic apparatus prevented the release of gas to be consumed by the atmosphere and gas entrainment. With the utilization of this procedure, the functionality of the gas expansion additive was fully attained without hindering performance and the gas release profile was controlled. This technique exhibited reproducibility and the theoretical gas release volumes were as calculated.\n After placement, the cement systems must preserve their integrity and provide zonal isolation during the life of the well. It has been possible to accommodate a wide range of conditions through the development of cementing additives that modify different Portland cements for their individual well requirements. During the hardening phase of a standard proportional cement to water content, the cement system becomes solid with low permeability. As a result of the cement matrix, the release of gas cannot migrate at a quantifiable rate with the partially water saturated pores. Low density cement systems with high water to cement ratios can exhibit high permeabilities. Therefore, it is possible for gas to flow and eventually reach the surface though at low rates. Additives are uniquely manufactured for gas expansion to prevent annulus shrinkage and high permeability; thereby preserving the integrity of the well isolation.","PeriodicalId":10983,"journal":{"name":"Day 1 Mon, April 08, 2019","volume":"53 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-03-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Day 1 Mon, April 08, 2019","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2118/193624-MS","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
In cementing applications, the release of gas is used to prevent shrinkage of the set cement in an annulus. With a significant decrease of volume of the wellbore, long term annular isolation may result in microfractures of the cement system; therefore, a failure of the cement bond (Go Boncan and Dillenbeck 2003). Currently, there is not a recommended procedure to quantitatively measure cement additives that facilitate gas expansion. This paper describes a methodical approach to quantify gas expansion within cement slurries.
Traditionally, a known rudimentary technique in measuring gas expansion in cement slurries is to use a glass beaker and to record the observations. Under static and atmospheric conditions, a graduated cylinder has been used to quantitatively measure the displacement of gas release within the annulus at ambient conditions. The new method developed in this paper will demonstrate that gas was being expelled into the atmosphere when the cement slurry containing gas generating additives was tested under ambient conditions. The procedure developed here will demonstrate that gas was entrained within the cement matrix.
An initial assessment of varying particle sizes of coated aluminum granules in a caustic solution showed that a consistent volume of gas was released. This working hypothesis was substantiated by measuring the volume of gas released within a closed system using a data logger. To ensure validation of this procedure, in-situ gas producing cement slurries were measured utilizing this method. With this experimental setup, quantifying the measurement of released gas from the cement matrix confirmed that variation of particle size does not affect performance.
Gas volume displacement measurement using an inverted graduated cylinder was set up to quantitatively determine the volume of the released gas within the cement matrix with the utilization of a stir plate. The system utilized polytetrafluorethylene tubing to transport the released gas that was produced from the matrix to the inverted graduated cylinder that was filled with deionized water. The released gas volume was assessed by displacement.
The enclosed dynamic apparatus with an inverted graduated cylinder was fitted with a paddle. This experimental setup enabled a homogenous blend and prevented void formation as the matrix was continuously agitated. This enclosed dynamic apparatus prevented the release of gas to be consumed by the atmosphere and gas entrainment. With the utilization of this procedure, the functionality of the gas expansion additive was fully attained without hindering performance and the gas release profile was controlled. This technique exhibited reproducibility and the theoretical gas release volumes were as calculated.
After placement, the cement systems must preserve their integrity and provide zonal isolation during the life of the well. It has been possible to accommodate a wide range of conditions through the development of cementing additives that modify different Portland cements for their individual well requirements. During the hardening phase of a standard proportional cement to water content, the cement system becomes solid with low permeability. As a result of the cement matrix, the release of gas cannot migrate at a quantifiable rate with the partially water saturated pores. Low density cement systems with high water to cement ratios can exhibit high permeabilities. Therefore, it is possible for gas to flow and eventually reach the surface though at low rates. Additives are uniquely manufactured for gas expansion to prevent annulus shrinkage and high permeability; thereby preserving the integrity of the well isolation.
在固井应用中,气体的释放用于防止环空固井水泥浆的收缩。随着井筒体积的显著减小,长期环空隔离可能会导致水泥体系出现微裂缝;因此,水泥粘结的失败(Go Boncan and Dillenbeck 2003)。目前,还没有一个推荐的方法来定量测量促进气体膨胀的水泥添加剂。本文描述了一种量化水泥浆中气体膨胀的方法。传统上,测量水泥浆中气体膨胀的一种已知的基本技术是使用玻璃烧杯并记录观察结果。在静态和常压条件下,采用分度圆柱体定量测量环空气体释放位移。本文开发的新方法将证明,当在环境条件下测试含有产气添加剂的水泥浆时,气体被排出到大气中。这里开发的程序将证明气体被夹带在水泥基质中。在苛性碱溶液中,对不同粒径的涂覆铝颗粒的初步评估表明,释放了一致体积的气体。通过使用数据记录仪测量封闭系统内释放的气体体积,证实了这一工作假设。为了确保该程序的有效性,利用该方法对现场产气水泥浆进行了测量。通过该实验装置,量化了水泥基质中释放气体的测量结果,证实了颗粒大小的变化不会影响性能。利用搅拌板,建立了用倒刻度圆筒进行气体体积位移测量的方法,定量测定水泥基体内释放气体的体积。该系统利用聚四氟乙烯管将从基质中产生的释放气体输送到装满去离子水的倒置分级圆柱体中。通过驱替来评估释放的气体体积。倒置刻度圆柱体的封闭式动力装置装有桨叶。该实验装置使混合均匀,并防止了基体连续搅拌时形成空隙。这种封闭的动力装置防止气体被大气消耗和气体夹带的释放。利用该方法,在不影响性能的情况下,充分发挥了气体膨胀添加剂的功能,并控制了气体释放曲线。该方法重现性好,理论气体释放量与计算结果一致。安装后,水泥系统必须保持其完整性,并在井的生命周期内提供层间隔离。通过开发水泥添加剂,可以根据不同的井要求对不同的波特兰水泥进行改性,从而可以适应各种不同的条件。在水泥与水的标准比例硬化阶段,水泥体系变得固体,渗透率低。由于水泥基质的存在,在部分含水饱和的孔隙中,气体的释放不能以可量化的速率运移。具有高水灰比的低密度水泥体系具有高渗透率。因此,气体有可能以较低的速率流动并最终到达地面。为防止环空收缩和高渗透性而专门制造的气体膨胀添加剂;从而保持了井隔离的完整性。