Shamudra Dey, Tahsin Ibtida, C. Roy, Nuruzzaman Sakib
{"title":"Effect of Varying Anastomosis Angles for Non-Newtonian Pulsatile Blood Flow through Artery Bypass Graft Models: an LES Study","authors":"Shamudra Dey, Tahsin Ibtida, C. Roy, Nuruzzaman Sakib","doi":"10.1109/TENSYMP50017.2020.9230640","DOIUrl":null,"url":null,"abstract":"A computational analysis is performed using the Large Eddy Simulation (LES) method to predict non-Newtonian pulsatile flow of blood into Artery Bypass Graft (ABG) models with varying anastomosis angles. The traditional end-to-side bypass graft models of three distinct anastomosis angles (30°, 45° & 60°) are created on the 75% idealized arterial stenosis to serve the purpose of vascular reconstruction. A pulsatile parabolic inlet boundary condition with the contemplation of spiral component is formulated to model the naturalistic flow in the blood vessel & non-Newtonian Carreau viscosity model is used. The transient study was performed in the ANSYS Fluent 15.0. Initially, the numerical simulation process has been validated with the results of a classic experimental study and Direct Numerical Simulation (DNS) study. The numerical study found that wall shear stress has significant effect on re-blocking while pressure has smaller effect. The artery bypass configuration of 30° anastomosis angle is the most favorable one for the common end-to-side graft design. As a whole, the LES study has provided basic but novel observations of flow projection in the specific artery bypass graft (ABG) models.","PeriodicalId":6721,"journal":{"name":"2020 IEEE Region 10 Symposium (TENSYMP)","volume":"2 1","pages":"1494-1497"},"PeriodicalIF":0.0000,"publicationDate":"2020-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE Region 10 Symposium (TENSYMP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TENSYMP50017.2020.9230640","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
A computational analysis is performed using the Large Eddy Simulation (LES) method to predict non-Newtonian pulsatile flow of blood into Artery Bypass Graft (ABG) models with varying anastomosis angles. The traditional end-to-side bypass graft models of three distinct anastomosis angles (30°, 45° & 60°) are created on the 75% idealized arterial stenosis to serve the purpose of vascular reconstruction. A pulsatile parabolic inlet boundary condition with the contemplation of spiral component is formulated to model the naturalistic flow in the blood vessel & non-Newtonian Carreau viscosity model is used. The transient study was performed in the ANSYS Fluent 15.0. Initially, the numerical simulation process has been validated with the results of a classic experimental study and Direct Numerical Simulation (DNS) study. The numerical study found that wall shear stress has significant effect on re-blocking while pressure has smaller effect. The artery bypass configuration of 30° anastomosis angle is the most favorable one for the common end-to-side graft design. As a whole, the LES study has provided basic but novel observations of flow projection in the specific artery bypass graft (ABG) models.