Automated on-line liquid-liquid extraction in a multisyringe flow injection analysis manifold for migration studies in food-contact materials: analysis of 4,4´-dihydroxybiphenyl

I. Delgado-Blanca, E. Llorent-Martínez, A. Ruiz-Medina, Ortega-Barrales Pilar
{"title":"Automated on-line liquid-liquid extraction in a multisyringe flow injection analysis manifold for migration studies in food-contact materials: analysis of 4,4´-dihydroxybiphenyl","authors":"I. Delgado-Blanca, E. Llorent-Martínez, A. Ruiz-Medina, Ortega-Barrales Pilar","doi":"10.1080/19440049.2019.1678769","DOIUrl":null,"url":null,"abstract":"ABSTRACT Packaging may represent a source of food contamination, as different organic compounds and degradation compounds may migrate from packaging to foodstuff. For fatty foods, rectified olive oil is the common simulant, which implies time-consuming and laborious liquid-liquid extraction (LLE) procedures to isolate the contaminant(s) from the oil. Here we propose a Multisyringe Flow Injection Analysis manifold to automate this sample treatment, using the monomer 4,4´-dihydroxybiphenyl as the contaminant. The LLE procedure, using water as extractant, was fully automated. After the on-line LLE, the resulting extract was pumped through a fluorescence detector, inside which a flow-cell filled with C18 silica gel solid support was placed. The analyte was pre-concentrated on the solid support (in which the analytical signal was directly recorded), so improving the sensitivity of the system. Under optimum conditions, the method detection limit is 0.05 mg kg−1, well within the specific migration limit of 6 mg kg−1. The method developed was compared with the standard CEN test method (off-line LLE and HPLC determination) observing savings in sample and reagents of 90% and a 7-fold increase in sample throughput. Graphical abstract","PeriodicalId":12121,"journal":{"name":"Food Additives & Contaminants: Part A","volume":"9 1","pages":"174 - 182"},"PeriodicalIF":0.0000,"publicationDate":"2020-01-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Food Additives & Contaminants: Part A","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/19440049.2019.1678769","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

ABSTRACT Packaging may represent a source of food contamination, as different organic compounds and degradation compounds may migrate from packaging to foodstuff. For fatty foods, rectified olive oil is the common simulant, which implies time-consuming and laborious liquid-liquid extraction (LLE) procedures to isolate the contaminant(s) from the oil. Here we propose a Multisyringe Flow Injection Analysis manifold to automate this sample treatment, using the monomer 4,4´-dihydroxybiphenyl as the contaminant. The LLE procedure, using water as extractant, was fully automated. After the on-line LLE, the resulting extract was pumped through a fluorescence detector, inside which a flow-cell filled with C18 silica gel solid support was placed. The analyte was pre-concentrated on the solid support (in which the analytical signal was directly recorded), so improving the sensitivity of the system. Under optimum conditions, the method detection limit is 0.05 mg kg−1, well within the specific migration limit of 6 mg kg−1. The method developed was compared with the standard CEN test method (off-line LLE and HPLC determination) observing savings in sample and reagents of 90% and a 7-fold increase in sample throughput. Graphical abstract
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于食品接触材料迁移研究的多注射器流动注射分析歧管中的自动在线液-液萃取:4,4´-二羟基联苯的分析
包装可能是食品污染源之一,因为不同的有机化合物和降解化合物可能从包装转移到食品中。对于高脂肪食品,精炼橄榄油是常见的模拟物,这意味着耗时且费力的液-液萃取(LLE)程序来从油中分离污染物。在这里,我们提出了一个多注射器流动注射分析歧管自动化样品处理,使用单体4,4´-二羟基联苯作为污染物。LLE过程以水为萃取剂,完全自动化。在线LLE后,将得到的提取物通过荧光检测器泵送,在荧光检测器内放置充满C18硅胶固体载体的流动池。分析物被预先浓缩在固体载体上(在固体载体上直接记录分析信号),从而提高了系统的灵敏度。在最佳条件下,该方法的检出限为0.05 mg kg - 1,完全在6 mg kg - 1的特定迁移限内。将该方法与标准的CEN测试方法(离线LLE和HPLC测定)进行比较,发现样品和试剂节省90%,样品通量提高7倍。图形抽象
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Infant nutrition at risk: a global systematic review of ochratoxin A in human breast milk-human health risk assessment. Determination and evaluation of canthaxanthin and β-apo-8'-carotenoid ethyl ester in chicken eggs and meat in Tianjin. A worldwide systematic review of ochratoxin A in various coffee products - human exposure and health risk assessment. Determination of azodicarbonamide in flour samples using high-performance liquid chromatography-tandem mass spectrometry with xanthydrol pre-column derivatisation. Food process contaminants: formation, occurrence, risk assessment and mitigation strategies – a review
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1