{"title":"Automation in flow-injection analysis: Simultaneous determination of chloride and total iron","authors":"José Y. Neira, Joaquim A. Nóbrega","doi":"10.1002/(SICI)1098-2728(1999)11:5<260::AID-LRA3>3.0.CO;2-Y","DOIUrl":null,"url":null,"abstract":"<p>In this article, we describe an automated flow-injection system for simultaneous determination of Cl<sup>−</sup> and total Fe. Chloride was potentiometrically determined, and total Fe was colorimetrically determined after reduction of Fe(III) to Fe(II) and complexation with 1,10-phenanthroline. Both measurements were performed simultaneously, and the signals were continuously shown on the computer video screen. A Turbo Basic program was written to activate the peristaltic pump, valves, and to control signal acquisition and treatment. The operator only needs to inject the samples, and all the others steps are performed by the automated system. The system presented a sampling frequency of 60 h<sup>−1</sup>, that is, 120 simultaneous determinations of Cl<sup>−</sup> and total Fe. © 1999 John Wiley & Sons, Inc. Lab Robotics and Automation 11: 260–265, 1999</p>","PeriodicalId":100863,"journal":{"name":"Laboratory Robotics and Automation","volume":"11 5","pages":"260-265"},"PeriodicalIF":0.0000,"publicationDate":"1999-10-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/(SICI)1098-2728(1999)11:5<260::AID-LRA3>3.0.CO;2-Y","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Laboratory Robotics and Automation","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/%28SICI%291098-2728%281999%2911%3A5%3C260%3A%3AAID-LRA3%3E3.0.CO%3B2-Y","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
In this article, we describe an automated flow-injection system for simultaneous determination of Cl− and total Fe. Chloride was potentiometrically determined, and total Fe was colorimetrically determined after reduction of Fe(III) to Fe(II) and complexation with 1,10-phenanthroline. Both measurements were performed simultaneously, and the signals were continuously shown on the computer video screen. A Turbo Basic program was written to activate the peristaltic pump, valves, and to control signal acquisition and treatment. The operator only needs to inject the samples, and all the others steps are performed by the automated system. The system presented a sampling frequency of 60 h−1, that is, 120 simultaneous determinations of Cl− and total Fe. © 1999 John Wiley & Sons, Inc. Lab Robotics and Automation 11: 260–265, 1999
流动注射分析中的自动化:氯化物和总铁的同时测定
在本文中,我们描述了一个自动流动注射系统,同时测定Cl−和总铁。氯离子用电位法测定,铁(III)还原为铁(II)并与1,10-菲罗啉络合后,用比色法测定总铁。两种测量同时进行,并且信号连续地显示在计算机视频屏幕上。编写了一个Turbo Basic程序来激活蠕动泵、阀门,并控制信号的采集和处理。操作人员只需注入样品,其余步骤均由自动化系统完成。该系统的采样频率为60 h−1,即同时测定120个Cl−和总Fe。©1999 John Wiley &儿子,Inc。实验室机器人控制与自动化,1999
本文章由计算机程序翻译,如有差异,请以英文原文为准。