Analysis of hematological metal element levels in orthopedic patients with implants

Q3 Biochemistry, Genetics and Molecular Biology Journal of Natural Science, Biology, and Medicine Pub Date : 2020-01-01 DOI:10.4103/jnsbm.JNSBM_120_19
V. Sengodan, Shreyas Doddihithlu
{"title":"Analysis of hematological metal element levels in orthopedic patients with implants","authors":"V. Sengodan, Shreyas Doddihithlu","doi":"10.4103/jnsbm.JNSBM_120_19","DOIUrl":null,"url":null,"abstract":"Background: The progressive increase in concentration of circulating metal by-products derived from the metal-based orthopedic implants may have deleterious effects in the patients over the long term. Therefore, it is necessary to profile the metal levels in the body of the patients receiving metal implants using appropriate highly sensitive techniques and strategies. Hence, in this study, we estimated the levels of metal in serum of patients with metal implants. Materials and Methods: Blood samples of 25 patients with metallic implants were collected at 6 months postsurgery. The blood samples were subjected to triple acid digestion and then analyzed through inductively coupled plasma–mass spectroscopy, and the blood levels of various metals were quantified. Results: An increase in serum levels of titanium was observed in the patients with metal implants at 6 months postsurgical implant. However, the levels of titanium were within the normal range (normal level <7.2 μg/l), and we did not observe any signs of detectable systemic toxicity. In contrast, the mean serum levels of cobalt (0.19–2.6 μg/l) and nickel (0.05–1.08 μg/l) were above the normal range. Conclusion: Orthopedic patients with metal implants had the serum levels of titanium within the normal range but had serum levels of cobalt and nickel above the normal range. Despite increase in the serum levels of cobalt and nickel, the patients did not show any clinical signs of toxicity.","PeriodicalId":16373,"journal":{"name":"Journal of Natural Science, Biology, and Medicine","volume":"252 1","pages":"17 - 20"},"PeriodicalIF":0.0000,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Natural Science, Biology, and Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jnsbm.JNSBM_120_19","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Biochemistry, Genetics and Molecular Biology","Score":null,"Total":0}
引用次数: 1

Abstract

Background: The progressive increase in concentration of circulating metal by-products derived from the metal-based orthopedic implants may have deleterious effects in the patients over the long term. Therefore, it is necessary to profile the metal levels in the body of the patients receiving metal implants using appropriate highly sensitive techniques and strategies. Hence, in this study, we estimated the levels of metal in serum of patients with metal implants. Materials and Methods: Blood samples of 25 patients with metallic implants were collected at 6 months postsurgery. The blood samples were subjected to triple acid digestion and then analyzed through inductively coupled plasma–mass spectroscopy, and the blood levels of various metals were quantified. Results: An increase in serum levels of titanium was observed in the patients with metal implants at 6 months postsurgical implant. However, the levels of titanium were within the normal range (normal level <7.2 μg/l), and we did not observe any signs of detectable systemic toxicity. In contrast, the mean serum levels of cobalt (0.19–2.6 μg/l) and nickel (0.05–1.08 μg/l) were above the normal range. Conclusion: Orthopedic patients with metal implants had the serum levels of titanium within the normal range but had serum levels of cobalt and nickel above the normal range. Despite increase in the serum levels of cobalt and nickel, the patients did not show any clinical signs of toxicity.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
骨科植入物患者血液金属元素水平分析
背景:金属基骨科植入物产生的循环金属副产物浓度的逐渐增加可能对患者产生长期的有害影响。因此,有必要使用适当的高灵敏度技术和策略来分析接受金属植入物的患者体内的金属水平。因此,在本研究中,我们估计了金属种植体患者血清中的金属水平。材料与方法:收集25例金属种植体患者术后6个月的血液标本。血液样品经三次酸消化,然后通过电感耦合等离子体质谱分析,并定量血液中各种金属的含量。结果:金属种植体患者术后6个月血清钛水平升高。然而,钛的水平在正常范围内(正常水平<7.2 μg/l),我们没有观察到任何可检测到的全身毒性迹象。血清钴(0.19 ~ 2.6 μg/l)、镍(0.05 ~ 1.08 μg/l)均高于正常水平。结论:骨科植入金属种植体患者血清钛含量在正常范围内,钴、镍含量高于正常范围。尽管血清中钴和镍含量增加,但患者未表现出任何临床毒性症状。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Natural Science, Biology, and Medicine
Journal of Natural Science, Biology, and Medicine Biochemistry, Genetics and Molecular Biology-Biochemistry, Genetics and Molecular Biology (all)
CiteScore
2.40
自引率
0.00%
发文量
0
期刊最新文献
Biochemical role of zinc in dengue fever Concentration of chromium and nickel in serum of patients with orthopedic implant: An analysis Self-reliance in advanced diagnostic imaging for accessible, affordable, and quality health care in India A rare occurrence of calcifying epithelial odontogenic tumor in a young female Effects of muscle-specific exercises compared to existing interventions on insulin resistance among prediabetes population of South India
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1