Performance of a scintillator glass shower detector for 20–120 MeV electrons

Masaaki Kobayashi, Yoshio Yoshimura, Masami Chiba, Jun'ichiro Iwahori, Hajime Yoshida
{"title":"Performance of a scintillator glass shower detector for 20–120 MeV electrons","authors":"Masaaki Kobayashi,&nbsp;Yoshio Yoshimura,&nbsp;Masami Chiba,&nbsp;Jun'ichiro Iwahori,&nbsp;Hajime Yoshida","doi":"10.1016/0029-554X(81)90737-0","DOIUrl":null,"url":null,"abstract":"<div><p>A scintillator glass (type : SCG1B) detector of 14 × 14 × 40 cm<sup>3</sup> gives an energy resolution (fwhm) of <span><math><mtext>6.5%/E</mtext><msup><mi></mi><mn><mtext>−1</mtext><mtext>2</mtext></mn></msup></math></span> for low energy electrons, which is better than for lead glass by a factor approximately 0.6. The light yield for SCG1B is 3.4 times that for lead glass (SF5) if the blocks have similar dimensions. Different surface textures are also compared.</p></div>","PeriodicalId":100971,"journal":{"name":"Nuclear Instruments and Methods","volume":"184 2","pages":"Pages 399-404"},"PeriodicalIF":0.0000,"publicationDate":"1981-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0029-554X(81)90737-0","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear Instruments and Methods","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/0029554X81907370","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

Abstract

A scintillator glass (type : SCG1B) detector of 14 × 14 × 40 cm3 gives an energy resolution (fwhm) of 6.5%/E−12 for low energy electrons, which is better than for lead glass by a factor approximately 0.6. The light yield for SCG1B is 3.4 times that for lead glass (SF5) if the blocks have similar dimensions. Different surface textures are also compared.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
20 - 120mev电子闪烁玻璃淋浴探测器的性能
一个14 × 14 × 40 cm3的闪烁玻璃(类型:SCG1B)探测器对低能电子的能量分辨率(fwhm)为6.5%/E - 12,比铅玻璃的能量分辨率高约0.6倍。如果块状尺寸相似,SCG1B的出光率是铅玻璃(SF5)的3.4倍。还比较了不同的表面纹理。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Development of Accelerator Mass Spectroscopy Techniques for Measuring $^3$He-$^4$He Isotopic Ratios Testing of Bulk Radiation Damage of n-in-p Silicon Sensors for Very High Radiation Environments Atomic, Molecular, and Optical Physics with X-rays Subject index Author index
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1