On-Line Preconcentration/Determination of Lead Traces in Bee Honey by Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES) Using a Conical Minicolumn Packed with Activated Carbon
S. Cerutti, R. F. Orsi, J. Gásquez, R. Olsina, L. Martínez
{"title":"On-Line Preconcentration/Determination of Lead Traces in Bee Honey by Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES) Using a Conical Minicolumn Packed with Activated Carbon","authors":"S. Cerutti, R. F. Orsi, J. Gásquez, R. Olsina, L. Martínez","doi":"10.1081/TMA-120023059","DOIUrl":null,"url":null,"abstract":"Abstract In this study, the preconcentration of Pb2+ using a conical minicolumn packed with activated carbon (AC) was studied for preconcentration of Pb2+. The experiments showed that Pb2+ reacts with 8-hydroxyquinoline to form a complex at pH 10.0 and can be retained “on-line” on a conical minicolumn packed with activated carbon, then eluted with 20% (v/v) nitric acid. The conditions for the quantitative and reproducible preconcentration and subsequent ICP-OES determination with ultrasonic nebulization system (USN) were studied. A total enhancement factor (N) of 500 was obtained with respect to ICP-OES using pneumatic nebulization (10 for USN and 50 for enrichment factor) for a sample volume of 25 mL. The detection limit (DL) was 0.04 µg L−1. The relative standard deviation (RSD) were 3.0%. The optimized procedure was successfully applied to the determination of trace levels of Pb+2 in bee honey samples.","PeriodicalId":17525,"journal":{"name":"Journal of Trace and Microprobe Techniques","volume":"23 1","pages":"421 - 432"},"PeriodicalIF":0.0000,"publicationDate":"2003-01-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Trace and Microprobe Techniques","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1081/TMA-120023059","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13
Abstract
Abstract In this study, the preconcentration of Pb2+ using a conical minicolumn packed with activated carbon (AC) was studied for preconcentration of Pb2+. The experiments showed that Pb2+ reacts with 8-hydroxyquinoline to form a complex at pH 10.0 and can be retained “on-line” on a conical minicolumn packed with activated carbon, then eluted with 20% (v/v) nitric acid. The conditions for the quantitative and reproducible preconcentration and subsequent ICP-OES determination with ultrasonic nebulization system (USN) were studied. A total enhancement factor (N) of 500 was obtained with respect to ICP-OES using pneumatic nebulization (10 for USN and 50 for enrichment factor) for a sample volume of 25 mL. The detection limit (DL) was 0.04 µg L−1. The relative standard deviation (RSD) were 3.0%. The optimized procedure was successfully applied to the determination of trace levels of Pb+2 in bee honey samples.