Special Cases during the Detection of the Hook Style Energy Theft in Overhead Low-Voltage Power Grids through HS-DET Method – Part 2: Different Measurement Differences, Feint “Smart” Hooks and Hook Interconnection Issues
{"title":"Special Cases during the Detection of the Hook Style Energy Theft in Overhead Low-Voltage Power Grids through HS-DET Method – Part 2: Different Measurement Differences, Feint “Smart” Hooks and Hook Interconnection Issues","authors":"A. Lazaropoulos","doi":"10.17737/TRE.2019.5.1.0083","DOIUrl":null,"url":null,"abstract":"On the basis of [1] and [2], this paper investigates the possibility of jamming the method of the detection of the hook style energy theft (HS-DET method) that is used for the detection of the hook style energy theft in the overhead low-voltage (OV LV) power grids. Three more sophisticated scenarios, which have been revealed in [2] and are the evolution of the three main suspicious issues of [1], are further investigated in this paper. The detection efficiency of HS-DET method is assessed by using the already validated percent error sum (PES) submetrics and appropriate contour plots. Citation: Lazaropoulos, A. G. (2019). Special Cases during the Detection of the Hook Style Energy Theft in Overhead Low-Voltage Power Grids through HS-DET Method – Part 2: Different Measurement Differences, Feint “Smart” Hooks and Hook Interconnection Issues. Trends in Renewable Energy, 5, 90-116. DOI: 10.17737/tre.2019.5.1.0083","PeriodicalId":23305,"journal":{"name":"Trends in Renewable Energy","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Trends in Renewable Energy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17737/TRE.2019.5.1.0083","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5
Abstract
On the basis of [1] and [2], this paper investigates the possibility of jamming the method of the detection of the hook style energy theft (HS-DET method) that is used for the detection of the hook style energy theft in the overhead low-voltage (OV LV) power grids. Three more sophisticated scenarios, which have been revealed in [2] and are the evolution of the three main suspicious issues of [1], are further investigated in this paper. The detection efficiency of HS-DET method is assessed by using the already validated percent error sum (PES) submetrics and appropriate contour plots. Citation: Lazaropoulos, A. G. (2019). Special Cases during the Detection of the Hook Style Energy Theft in Overhead Low-Voltage Power Grids through HS-DET Method – Part 2: Different Measurement Differences, Feint “Smart” Hooks and Hook Interconnection Issues. Trends in Renewable Energy, 5, 90-116. DOI: 10.17737/tre.2019.5.1.0083