Histologic and histomorphometric evaluation of minicono abutment on implant surrounding tissue healing and bone resorption on implants placed in healed bone. An experimental study in dogs

IF 1 Q4 ENGINEERING, BIOMEDICAL AIMS Bioengineering Pub Date : 2023-01-01 DOI:10.3934/bioeng.2023013
J. Calvo-Guirado, Marta Belén Cabo-Pastor, F. Martínez-Martínez, M. Garcés-Villalá, Félix de Carlos-Villafranca, N. García-Carrillo, M. Fernández-Domínguez
{"title":"Histologic and histomorphometric evaluation of minicono abutment on implant surrounding tissue healing and bone resorption on implants placed in healed bone. An experimental study in dogs","authors":"J. Calvo-Guirado, Marta Belén Cabo-Pastor, F. Martínez-Martínez, M. Garcés-Villalá, Félix de Carlos-Villafranca, N. García-Carrillo, M. Fernández-Domínguez","doi":"10.3934/bioeng.2023013","DOIUrl":null,"url":null,"abstract":"The objective of this evaluation was to measure the width and length of connective tissue (CT) and crestal bone resorption (CBR) related to minicono® abutment inserted in conical connection dental implants, which were placed crestal and subcrestally in a dog's mandible. Materials and Methods Forty-eight Top DM implants with the same coronal diameter were placed at the crestal level, 1 mm (test 1 group) and 2 mm (test 2 group) positions underneath buccal-lingual bone crests. Dental implants used in the study were separated into three groups of 16 implants each. The implants were randomly inserted into healed bone after two months post-extraction sockets of three lower premolars, and first molar, bilaterally in six male fox hound dogs. One 3 mm minicono height abutment was connected to conical connection implants placed at the crestal level (control), 1 mm (test 1) and 2 mm (test 2) positions under buccal-lingual crests. Results All abutments and implants used were clinically and histologically integrated into the bone-soft tissue. Soft tissue behavior was observed at eight and 12 weeks in all test groups, displaying similar quantitative findings with significant differences (p > 0.05). However, crestal bone loss was significantly greater at the buccal side around that control group compared to the test 1 and 2 groups. The difference values between groups at the implant shoulder to the top of the lingual bone crest (IS-LBC) and the implant shoulder to the top of the buccal bone crest (IS-BBC) were significantly greater for the test 2 group in comparison with the other two groups (p < 0.05) at eight weeks. In addition, crestal bone resorption (CBR) increased in the crestal group at twelve weeks, but it was reduced for the test 1 and test 2 groups in implants placed sub-crestally (p < 0.05). Conclusions Crestal bone loss could be reduced using a 3 mm high abutment on implants submerged below the bone crest from 1 to 2 mm positions.","PeriodicalId":45029,"journal":{"name":"AIMS Bioengineering","volume":"8 1","pages":""},"PeriodicalIF":1.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"AIMS Bioengineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3934/bioeng.2023013","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

The objective of this evaluation was to measure the width and length of connective tissue (CT) and crestal bone resorption (CBR) related to minicono® abutment inserted in conical connection dental implants, which were placed crestal and subcrestally in a dog's mandible. Materials and Methods Forty-eight Top DM implants with the same coronal diameter were placed at the crestal level, 1 mm (test 1 group) and 2 mm (test 2 group) positions underneath buccal-lingual bone crests. Dental implants used in the study were separated into three groups of 16 implants each. The implants were randomly inserted into healed bone after two months post-extraction sockets of three lower premolars, and first molar, bilaterally in six male fox hound dogs. One 3 mm minicono height abutment was connected to conical connection implants placed at the crestal level (control), 1 mm (test 1) and 2 mm (test 2) positions under buccal-lingual crests. Results All abutments and implants used were clinically and histologically integrated into the bone-soft tissue. Soft tissue behavior was observed at eight and 12 weeks in all test groups, displaying similar quantitative findings with significant differences (p > 0.05). However, crestal bone loss was significantly greater at the buccal side around that control group compared to the test 1 and 2 groups. The difference values between groups at the implant shoulder to the top of the lingual bone crest (IS-LBC) and the implant shoulder to the top of the buccal bone crest (IS-BBC) were significantly greater for the test 2 group in comparison with the other two groups (p < 0.05) at eight weeks. In addition, crestal bone resorption (CBR) increased in the crestal group at twelve weeks, but it was reduced for the test 1 and test 2 groups in implants placed sub-crestally (p < 0.05). Conclusions Crestal bone loss could be reduced using a 3 mm high abutment on implants submerged below the bone crest from 1 to 2 mm positions.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
微创基台对种植体周围组织愈合及愈合骨内种植体骨吸收的组织学和组织形态学评价。一项对狗的实验研究
本评估的目的是测量在犬下颌骨牙冠和牙下放置的锥形牙种植体中插入minicono®基台时结缔组织(CT)和牙冠骨吸收(CBR)的宽度和长度。材料与方法将48颗冠状直径相同的Top DM种植体分别放置于牙冠水平、颊舌骨嵴下1 mm(试验1组)和2 mm(试验2组)位置。研究中使用的牙种植体被分为三组,每组16个种植体。6只雄性狐犬在拔牙后2个月随机植入3颗下前磨牙和第一磨牙的牙槽。在牙冠水平(对照)、牙冠下方1毫米(试验1)和2毫米(试验2)位置放置一个3毫米的迷你牙基与锥形连接种植体连接。结果所使用的基牙和种植体在临床和组织学上均与骨软组织结合良好。各组动物在第8周和第12周的软组织行为观察,定量结果相似,差异有统计学意义(p > 0.05)。然而,与试验1和试验2组相比,对照组颊侧的牙冠骨丢失明显更大。8周时,试验2组种植肩至舌骨嵴顶部(IS-LBC)和种植肩至颊骨嵴顶部(IS-BBC)两组间差异显著(p < 0.05)。12周时,牙冠组牙冠骨吸收(CBR)增加,而试验1和试验2组牙冠下种植体的CBR降低(p < 0.05)。结论将种植体埋于骨嵴以下1 ~ 2 mm位置,采用3mm高的基台可减少侧骨丢失。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
AIMS Bioengineering
AIMS Bioengineering ENGINEERING, BIOMEDICAL-
自引率
0.00%
发文量
17
审稿时长
4 weeks
期刊最新文献
Real data-based optimal control strategies for assessing the impact of the Omicron variant on heart attacks Decision support systems in healthcare: systematic review, meta-analysis and prediction, with example of COVID-19 Detection and analysis of coagulation effect in vein using MEMS laminar flow for the early heart stroke diagnosis An insight into the biomaterials used in craniofacial tissue engineering inclusive of regenerative dentistry Identification of diagnostic biomarkers of gestational diabetes mellitus based on transcriptome gene expression and alternations of microRNAs
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1