{"title":"UV Spectrophotometric Method Development and Validation of Carbimazole in Bulk and Tablet Dosage form","authors":"Zainab A. Bagalkote, G. Gajeli","doi":"10.52711/2231-5691.2021.00030","DOIUrl":null,"url":null,"abstract":"Objective: A new, simple, sensitive, precise, reproducible UV visible spectrophotometric method was developed for the estimation of Carbimazole in Tablet dosage form. Methods: The UV spectrum of Carbimazole in methanol and distilled water (30:70) showed λ max at 289.6nm. Beer’s law is valid in the concentration range of 10-50µg/ml. This method was validated for linearity, accuracy, precision, ruggedness and robustness. Results: The method has demonstrated excellent linearity over the range of 10-50µg/ml with the regression equation y = 0.0232x + 0.0466, and regression coefficient i.e, r2= 0.9992 moreover, the method was found to be highly sensitive with LOD (1.818µg/ml) and LOQ (5.509µg/ml). Conclusion: From the results it can be concluded that the given method can be successfully applied for assay of Carbimazole in Tablet dosage form.","PeriodicalId":8537,"journal":{"name":"Asian Journal of Pharmaceutical Research","volume":"47 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-08-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asian Journal of Pharmaceutical Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52711/2231-5691.2021.00030","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
Abstract
Objective: A new, simple, sensitive, precise, reproducible UV visible spectrophotometric method was developed for the estimation of Carbimazole in Tablet dosage form. Methods: The UV spectrum of Carbimazole in methanol and distilled water (30:70) showed λ max at 289.6nm. Beer’s law is valid in the concentration range of 10-50µg/ml. This method was validated for linearity, accuracy, precision, ruggedness and robustness. Results: The method has demonstrated excellent linearity over the range of 10-50µg/ml with the regression equation y = 0.0232x + 0.0466, and regression coefficient i.e, r2= 0.9992 moreover, the method was found to be highly sensitive with LOD (1.818µg/ml) and LOQ (5.509µg/ml). Conclusion: From the results it can be concluded that the given method can be successfully applied for assay of Carbimazole in Tablet dosage form.