{"title":"An investigation into the effects of prosthesis relevant surfaces on the formation of Staphylococcus aureus biofilms","authors":"Christopher Jackson, P. Bills, P. Humphreys, Carolanne Allen","doi":"10.1088/2051-672X/acdc3e","DOIUrl":null,"url":null,"abstract":"The aim of this study was to investigate the effects prosthesis relevant surfaces and finishes have on the formation of Staphylococcus aureus (S. aureus) biofilms, the leading causative pathogenic bacteria of periprosthetic joint infection (PJI). Microbiological biofilm analysis was conducted to quantify S. aureus biofilm growth on prosthesis relevant surface coatings and finishes. Through the use of a CDC Biofilm Reactor (CDC-BR), biofilms were grown under constant shear conditions on three different titanium surface finishes, including Plasma Spray (PS), Grit Blasted (GB) and an As-fabricated (AF) surface used for comparative and control purposes. Advanced metrological techniques were applied to characterise each surface. This advanced approach to surface characterisation, including functional volume parameters has been carried out to provide a detailed quantifiable description of the surface and one that better relates to the nature of growth upon a surface. Results show that the PS surface exhibits a significant increase in biofilm growth in comparison to the GB and AF surfaces, with the AF surface showing the lowest amount of biofilm growth. Additionally, the morphology of the features of the PS coating allows for the biofilm accumulation to flourish in the re-entrant features across its topography. These findings highlight the difficulties of biofilm eradication and further complicate the design process of prosthetics, where features implemented to promote osseointegration simultaneously offer favourable locations for bacterial cell attachment and subsequent biofilm development, leading potentially, to PJI. There is a general consensus throughout literature regarding an apparent trend between an increase in Sa and an increase in biofilm formation (Zheng et al 2021 Frontiers in Bioengineering and Biotechnology 9 643722; Bridgens et al 2015 Surface and Coatings Technology 284; James et al 2019 Aesthetic Plast. Surg. 43 490–497). This study has shown that whilst this may generally be the case, the location of this surface area increase within the topography may be a more important observation.","PeriodicalId":22028,"journal":{"name":"Surface Topography: Metrology and Properties","volume":"28 1","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2023-06-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Surface Topography: Metrology and Properties","FirstCategoryId":"88","ListUrlMain":"https://doi.org/10.1088/2051-672X/acdc3e","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
引用次数: 0

Abstract

The aim of this study was to investigate the effects prosthesis relevant surfaces and finishes have on the formation of Staphylococcus aureus (S. aureus) biofilms, the leading causative pathogenic bacteria of periprosthetic joint infection (PJI). Microbiological biofilm analysis was conducted to quantify S. aureus biofilm growth on prosthesis relevant surface coatings and finishes. Through the use of a CDC Biofilm Reactor (CDC-BR), biofilms were grown under constant shear conditions on three different titanium surface finishes, including Plasma Spray (PS), Grit Blasted (GB) and an As-fabricated (AF) surface used for comparative and control purposes. Advanced metrological techniques were applied to characterise each surface. This advanced approach to surface characterisation, including functional volume parameters has been carried out to provide a detailed quantifiable description of the surface and one that better relates to the nature of growth upon a surface. Results show that the PS surface exhibits a significant increase in biofilm growth in comparison to the GB and AF surfaces, with the AF surface showing the lowest amount of biofilm growth. Additionally, the morphology of the features of the PS coating allows for the biofilm accumulation to flourish in the re-entrant features across its topography. These findings highlight the difficulties of biofilm eradication and further complicate the design process of prosthetics, where features implemented to promote osseointegration simultaneously offer favourable locations for bacterial cell attachment and subsequent biofilm development, leading potentially, to PJI. There is a general consensus throughout literature regarding an apparent trend between an increase in Sa and an increase in biofilm formation (Zheng et al 2021 Frontiers in Bioengineering and Biotechnology 9 643722; Bridgens et al 2015 Surface and Coatings Technology 284; James et al 2019 Aesthetic Plast. Surg. 43 490–497). This study has shown that whilst this may generally be the case, the location of this surface area increase within the topography may be a more important observation.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
假体相关表面对金黄色葡萄球菌生物膜形成影响的研究
本研究旨在探讨假体相关表面和表面处理对假体周围关节感染(PJI)的主要致病菌金黄色葡萄球菌(S. aureus)生物膜形成的影响。通过微生物生物膜分析,量化金黄色葡萄球菌在假体相关表面涂层和饰面上的生物膜生长情况。通过使用CDC生物膜反应器(CDC- br),在恒定剪切条件下在三种不同的钛表面上生长生物膜,包括等离子喷涂(PS),喷砂(GB)和As-fabricated (AF)表面,用于比较和对照目的。先进的计量技术被应用于表征每个表面。这种先进的表面表征方法,包括功能体积参数,已被用于提供表面的详细可量化描述,并且更好地与表面上生长的性质相关。结果表明,与GB和AF相比,PS表面的生物膜生长明显增加,AF表面的生物膜生长最少。此外,PS涂层特征的形态允许生物膜的积累在其地形的重新进入特征中蓬勃发展。这些发现强调了去除生物膜的困难,并进一步使假肢的设计过程复杂化,其中促进骨整合的特征同时为细菌细胞附着和随后的生物膜发育提供了有利的位置,可能导致PJI。文献中普遍认为Sa的增加与生物膜形成的增加之间存在明显的趋势(Zheng et al . 2021《生物工程与生物技术前沿》9 643722;brigens等2015年表面和涂层技术284;James等2019美学整形。外科杂志43 490-497)。这项研究表明,虽然这可能是普遍的情况,但这种表面积增加在地形中的位置可能是一个更重要的观察结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Surface Topography: Metrology and Properties
Surface Topography: Metrology and Properties Materials Science-Materials Chemistry
CiteScore
4.10
自引率
22.20%
发文量
183
期刊介绍: An international forum for academics, industrialists and engineers to publish the latest research in surface topography measurement and characterisation, instrumentation development and the properties of surfaces.
期刊最新文献
The microhardness, morphology and tribological property of TC4 subjected to machine hammer peening Surface profile inspection for large structures with laser scanning Evolution of tooth surface morphology and tribological properties of helical gears during mixed lubrication sliding wear Analysis of co-relation on LPBF process parameter on wear characteristics of Cu-Cr-Zr alloy Influence of titanium carbide particles on the characteristics of microarc oxidation layer on Ti6Al4V alloy
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1