{"title":"The Development of Diazinon Sensors using Polyvinyl Alcohol (PVA) Membrane CuO on Surface Screen-Printed Carbon Electrode (SPCE) as a Receptor","authors":"Anisa Resti, Ani Mulyasuryani, Diah Mardiana","doi":"10.21776/ub.jpacr.2019.008.02.468","DOIUrl":null,"url":null,"abstract":"The development of Diazinon sensor has been studied using polyvinyl alcohol (PVA-CuO membrane on the surface of the screen-printed carbon electrode (SPCE) as a receptor. The membrane used consisted of polyvinyl alcohol (PVA) 5% (w/v), citric acid 5% (w/v), glutaraldehyde 4% (v/v), Diazinon solution 40 ppm (v/v), and CuO 5% (w/v). This study established the effect of Diazinon at 0.01,0.02 and 0.03 (w/w). besides, the concentration of CuO was 0.5 and 1 (w/w). Signal measurements were carried out in the concentration range of the Diazinon 10-12 - 10-5 M solution in Britton-Robinson buffer at pH 2 - 5. Besides, the influence of the electrolyte type was studied using HCl pH 4, 10-5 M KCl, pH 3 phosphate and phosphate-KCl pH 3 buffers. The results of the Diazinon sensor characterization showed that the highest sensitivity was obtained at 42 mV/decade with a response time of 180 seconds.","PeriodicalId":22728,"journal":{"name":"The Journal of Pure and Applied Chemistry Research","volume":"44 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-06-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of Pure and Applied Chemistry Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21776/ub.jpacr.2019.008.02.468","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The development of Diazinon sensor has been studied using polyvinyl alcohol (PVA-CuO membrane on the surface of the screen-printed carbon electrode (SPCE) as a receptor. The membrane used consisted of polyvinyl alcohol (PVA) 5% (w/v), citric acid 5% (w/v), glutaraldehyde 4% (v/v), Diazinon solution 40 ppm (v/v), and CuO 5% (w/v). This study established the effect of Diazinon at 0.01,0.02 and 0.03 (w/w). besides, the concentration of CuO was 0.5 and 1 (w/w). Signal measurements were carried out in the concentration range of the Diazinon 10-12 - 10-5 M solution in Britton-Robinson buffer at pH 2 - 5. Besides, the influence of the electrolyte type was studied using HCl pH 4, 10-5 M KCl, pH 3 phosphate and phosphate-KCl pH 3 buffers. The results of the Diazinon sensor characterization showed that the highest sensitivity was obtained at 42 mV/decade with a response time of 180 seconds.