Assessment of the impact of forest plantations on the intensity of commercial frequency electromagnetic fields

M. Amirkhanian
{"title":"Assessment of the impact of forest plantations on the intensity of commercial frequency electromagnetic fields","authors":"M. Amirkhanian","doi":"10.22227/2305-5502.2019.2.10","DOIUrl":null,"url":null,"abstract":"Introduction. Influence of forest plantations on intensity of electromagnetic fields (EMF) of commercial frequency (50 Hz), generated by high voltage power transmission line (PTL), is considered.\n\nMaterials and methods. The study was conducted near the village of Boltino in the Moscow Region. The EMF measurements were made on two profiles perpendicular to the 500 kV PTL (power transmission line) axis, one of which passes through the forest area, the other one does not cross it. Measurements of commercial frequency electromagnetic fields (CFEMF) were carried out using a measurement device and antennas, designed to measure the intensities of magnetic and electrical fields.\n\nResults. The comparative analysis of the character of change of electric and magnetic components of EMF with distance from the PTL axis allowed to establish the effect of EMF intensity decrease starting from the forest area boundary. Diagrams show that EMF reduction effect is more pronounced for the electrical component.\n\nConclusions. The revealed effect to a certain extent shows the analogy of the forest area with the Faraday cage. However, such an analogy is not complete due to the fact that the forest area is not a perfectly conductive body, but has only a low conductivity. Additional EMF reduction occurs as a result of partial EMF energy absorption by the forest area","PeriodicalId":22024,"journal":{"name":"Stroitel stvo nauka i obrazovanie [Construction Science and Education]","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2019-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Stroitel stvo nauka i obrazovanie [Construction Science and Education]","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22227/2305-5502.2019.2.10","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction. Influence of forest plantations on intensity of electromagnetic fields (EMF) of commercial frequency (50 Hz), generated by high voltage power transmission line (PTL), is considered. Materials and methods. The study was conducted near the village of Boltino in the Moscow Region. The EMF measurements were made on two profiles perpendicular to the 500 kV PTL (power transmission line) axis, one of which passes through the forest area, the other one does not cross it. Measurements of commercial frequency electromagnetic fields (CFEMF) were carried out using a measurement device and antennas, designed to measure the intensities of magnetic and electrical fields. Results. The comparative analysis of the character of change of electric and magnetic components of EMF with distance from the PTL axis allowed to establish the effect of EMF intensity decrease starting from the forest area boundary. Diagrams show that EMF reduction effect is more pronounced for the electrical component. Conclusions. The revealed effect to a certain extent shows the analogy of the forest area with the Faraday cage. However, such an analogy is not complete due to the fact that the forest area is not a perfectly conductive body, but has only a low conductivity. Additional EMF reduction occurs as a result of partial EMF energy absorption by the forest area
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
人工林对商业频率电磁场强度影响的评价
介绍。考虑了人工林对高压输电线路(PTL)产生的商用频率(50 Hz)电磁场强度的影响。材料和方法。这项研究是在莫斯科州博尔蒂诺村附近进行的。电磁场测量是在垂直于500千伏输电线路轴线的两条剖面上进行的,其中一条穿过森林地区,另一条不穿过森林地区。商用频率电磁场(CFEMF)的测量使用了一个测量装置和天线,设计用于测量磁场和电场的强度。对比分析了电动势的电、磁分量随离PTL轴距离的变化特征,确立了从林区边界开始的电动势强度降低效应。图表显示,电动势降低效应对电气元件更为明显。所揭示的效果在一定程度上显示了森林区域与法拉第笼的相似性。然而,这样的类比是不完整的,因为森林地区并不是一个完美的导电体,而只是一个低导电体。由于森林地区吸收了部分电动势能量,产生了额外的电动势减少
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Модель взаимосвязи участников профессиональной деятельности в градостроительстве Концепция реновации микрорайона Опыт формирования научного аппарата и структуры кандидатской диссертации О новой подготовке специалистов-механиков для строительной отрасли Комбинация рекуператора с вытяжным воздухоприемным устройством для использования в механических вентиляционных системах
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1