Statistical treatments for rapid tests with discrete measuring range

A. Götzl, W. Riepe
{"title":"Statistical treatments for rapid tests with discrete measuring range","authors":"A. Götzl, W. Riepe","doi":"10.1002/1520-6521(2000)4:6<270::AID-FACT20>3.0.CO;2-6","DOIUrl":null,"url":null,"abstract":"Colorimetric determination of analytes with comparators is characterized by stepwise measuring. Standard deviation as well as confidence interval are based on the distribution of measuring values. No continuous distribution of measuring values can be obtained with the use of colorimetric methods. The measuring range is cut in intervals and the measuring values show discrete distribution (measuring steps or bins). The measuring steps are nonuniformly distributed over the measuring range. This is an attempt to calculate statistical measurements for these determination methods. It is shown that adding two measuring steps to the measuring value is a quick way to check whether limit levels are exceeded. © 2000 John Wiley & Sons, Inc. Field Analyt Chem Technol 4: 270–273, 2000","PeriodicalId":12132,"journal":{"name":"Field Analytical Chemistry and Technology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2000-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Field Analytical Chemistry and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/1520-6521(2000)4:6<270::AID-FACT20>3.0.CO;2-6","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Colorimetric determination of analytes with comparators is characterized by stepwise measuring. Standard deviation as well as confidence interval are based on the distribution of measuring values. No continuous distribution of measuring values can be obtained with the use of colorimetric methods. The measuring range is cut in intervals and the measuring values show discrete distribution (measuring steps or bins). The measuring steps are nonuniformly distributed over the measuring range. This is an attempt to calculate statistical measurements for these determination methods. It is shown that adding two measuring steps to the measuring value is a quick way to check whether limit levels are exceeded. © 2000 John Wiley & Sons, Inc. Field Analyt Chem Technol 4: 270–273, 2000
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
离散量程快速试验的统计处理
用比较器比色法测定分析物的特点是逐步测定。标准偏差和置信区间是基于测量值的分布。用比色法不能得到测量值的连续分布。测量范围在间隔中切割,测量值显示离散分布(测量步骤或箱)。测量步骤在测量范围内不均匀分布。这是为这些测定方法计算统计测量值的一次尝试。结果表明,在测量值上增加两个测量步骤是一种快速检查是否超过极限水平的方法。©2000 John Wiley & Sons, Inc化学工程学报(自然科学版),2000
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Development and evaluation of a low thermal mass gas chromatograph for rapid forensic GC–MS analyses Field detection and identification of a bioaerosol suite by pyrolysis-gas chromatography-ion mobility spectrometry* Multivariate data analysis of fluorescence signals from biological aerosols Biological agent detection and identification by the Block II Chemical Biological Mass Spectrometer Rapid determination of bacteria in drinking water using an ATP assay
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1