Clinical application value of Abbott Alinity analyzer in syphilis-specific antibody testing

IF 0.5 4区 医学 Q4 MEDICINE, RESEARCH & EXPERIMENTAL Revista Romana De Medicina De Laborator Pub Date : 2023-07-01 DOI:10.2478/rrlm-2023-0017
Shu-Guang Hou, Congcong Cheng, Shuhong Yan
{"title":"Clinical application value of Abbott Alinity analyzer in syphilis-specific antibody testing","authors":"Shu-Guang Hou, Congcong Cheng, Shuhong Yan","doi":"10.2478/rrlm-2023-0017","DOIUrl":null,"url":null,"abstract":"Abstract Background: We aimed to investigate the clinical application value of Abbott Alinity analyzer in syphilis-specific antibody testing. Methods: A total of 100 patients admitted from June 2021 to June 2022 for early syphilis diagnosis were selected and subjected to Treponema pallidum (TP) antibody testing by chemiluminescent microparticle immunoassay (CMIA) using Abbott Alinity analyzer. With TP particle agglutination (TPPA) retesting as the gold standard for syphilis diagnosis, the signal-to-cutoff (S/CO) ratio of the TP antibody testing was plotted into the receiver operating characteristic curve to determine the diagnostic value of CMIA and CLIA in detecting positive TP antibody and to identify the optimal cutoff point. Results: In the case of S/CO ratio ≥7.00, the patients with positive CMIA were diagnosed with positive findings after TPPA confirmation. With the S/CO ratio of 1.00-4.99, the coincidence rate of CLIA with positive TPPA was 81.82% (45/55), and all patients with positive CLIA had positive results confirmed by TPPA test when the S/CO ratio was >5.00. When the optimal cutoff value of S/CO ratio for TP was determined as 6.98 by CMIA, the sensitivity, specificity, and maximum area under the curve (AUC) were 94%, 88% and 0.91, respectively. At the optimal cutoff value (S/CO ratio: 4.56) determined by CLIA, the sensitivity was 84%, the specificity was 80%, and the maximum AUC was 0.84. Conclusions: In the case of S/CO ratio ≥7.00, both methods have high sensitivity and specificity, which can directly give positive reports and shorten the sample turnaround time.","PeriodicalId":49599,"journal":{"name":"Revista Romana De Medicina De Laborator","volume":"135 1","pages":"185 - 190"},"PeriodicalIF":0.5000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista Romana De Medicina De Laborator","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2478/rrlm-2023-0017","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract Background: We aimed to investigate the clinical application value of Abbott Alinity analyzer in syphilis-specific antibody testing. Methods: A total of 100 patients admitted from June 2021 to June 2022 for early syphilis diagnosis were selected and subjected to Treponema pallidum (TP) antibody testing by chemiluminescent microparticle immunoassay (CMIA) using Abbott Alinity analyzer. With TP particle agglutination (TPPA) retesting as the gold standard for syphilis diagnosis, the signal-to-cutoff (S/CO) ratio of the TP antibody testing was plotted into the receiver operating characteristic curve to determine the diagnostic value of CMIA and CLIA in detecting positive TP antibody and to identify the optimal cutoff point. Results: In the case of S/CO ratio ≥7.00, the patients with positive CMIA were diagnosed with positive findings after TPPA confirmation. With the S/CO ratio of 1.00-4.99, the coincidence rate of CLIA with positive TPPA was 81.82% (45/55), and all patients with positive CLIA had positive results confirmed by TPPA test when the S/CO ratio was >5.00. When the optimal cutoff value of S/CO ratio for TP was determined as 6.98 by CMIA, the sensitivity, specificity, and maximum area under the curve (AUC) were 94%, 88% and 0.91, respectively. At the optimal cutoff value (S/CO ratio: 4.56) determined by CLIA, the sensitivity was 84%, the specificity was 80%, and the maximum AUC was 0.84. Conclusions: In the case of S/CO ratio ≥7.00, both methods have high sensitivity and specificity, which can directly give positive reports and shorten the sample turnaround time.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Abbott Alinity分析仪在梅毒特异性抗体检测中的临床应用价值
摘要背景:探讨雅培Alinity分析仪在梅毒特异性抗体检测中的临床应用价值。方法:选择2021年6月~ 2022年6月收治的梅毒早期诊断患者100例,采用雅培Alinity分析仪进行梅毒螺旋体(Treponema pallidum, TP)抗体检测。以TP颗粒凝集(TPPA)复验作为梅毒诊断的金标准,将TP抗体检测的信号-截止(S/CO)比绘制到受试者工作特征曲线中,确定CMIA和CLIA检测TP抗体阳性的诊断价值,并确定最佳截止点。结果:S/CO比值≥7.00的CMIA阳性患者经TPPA确证均为阳性。当S/CO比值为1.00 ~ 4.99时,CLIA与TPPA阳性的符合率为81.82%(45/55),当S/CO比值>5.00时,所有CLIA阳性患者均经TPPA试验证实为阳性。当CMIA法确定TP的S/CO最佳临界值为6.98时,其灵敏度为94%,特异度为88%,曲线下最大面积(AUC)为0.91。在CLIA确定的最佳临界值(S/CO比值为4.56)下,灵敏度为84%,特异性为80%,最大AUC为0.84。结论:在S/CO比值≥7.00的情况下,两种方法均具有较高的敏感性和特异性,可直接给出阳性报告,缩短样品周转时间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Revista Romana De Medicina De Laborator
Revista Romana De Medicina De Laborator MEDICINE, RESEARCH & EXPERIMENTAL-
CiteScore
0.31
自引率
20.00%
发文量
43
审稿时长
>12 weeks
期刊介绍: The aim of the journal is to publish new information that would lead to a better understanding of biological mechanisms of production of human diseases, their prevention and diagnosis as early as possible and to monitor therapy and the development of the health of patients
期刊最新文献
Associations of levels of high-molecular-weight adiponectin, secreted frizzled-related protein 5 and vascular endothelial growth factor-165 with diabetic retinopathy The potential value of some adipokines and cytokines as diagnostic biomarkers for prostate cancer Correlations of special AT-rich sequence binding protein 2 and chitinase-3-like protein-1 with sensitivity to paclitaxel chemotherapy for gastric cancer Correlations of contrast-enhanced ultrasound parameters with free thyroxine, total thyroxine, thyroid peroxidase antibody and thyroglobulin antibody in patients with thyroid nodules Analyzing serum tryptophan metabolites in patients with gestational diabetes mellitus
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1