Development of a grid-connected photovoltaic-storage

A. S. C. Cardoso Diniz, L. M. Machado Neto, Suellen C. S. Costa, Marcio E. M. de Souza, F. F. Souza, Wilton C. Padrão, Flavio M. C. Michel, O. M. Toledo, D. O. Filho
{"title":"Development of a grid-connected photovoltaic-storage","authors":"A. S. C. Cardoso Diniz, L. M. Machado Neto, Suellen C. S. Costa, Marcio E. M. de Souza, F. F. Souza, Wilton C. Padrão, Flavio M. C. Michel, O. M. Toledo, D. O. Filho","doi":"10.1109/PVSC.2014.6925493","DOIUrl":null,"url":null,"abstract":"This paper presents the design and studies performed in the first-phase implementation of the R&D project D308, in partnership with Energetic Company of Minas Gerais (CEMIG-D). The objective of this project is to evaluate the benefits and limitations of using storage with a grid-connected PV system. Specifically to evaluate injecting the energy stored in batteries charge by the PV into the electric grid in order to flatten the peak of the load curve of a feeder system (with evening peak-electricity consumption experienced in this area). The PV/storage system is being installed in the football stadium Arena do Jacare, located in Sete Lagoas, Minas Gerais. Initial studies have been performed to define the characteristics of the PV array, including surveys of the region characteristics, and solar resource/ climate data. Additionally, the characteristics of the optimum PV generator configuration and module technology have been evaluated, taking into consideration the stadium's limited available area and defined orientation--and the major design criterion to eliminate any shadow projection on photovoltaic modules that could reduce its performance. With the initial design of the PV generator structure and geometry, the system was performance was simuulated under projected conditions. An innovative feature of this project is a bidirectional conversion and connection unit, which has the capacity to store the energy coming from the PV generator and/or the electrical network in a battery bank. The unit can deliver the energy to the grid (a feeder operated by CEMIG in our tests) at specific defined times-such as the peak time in this area between 18:30 and 20:30. At the conclusion of this protype project, a larger scale of the system (photovoltaic system connected to the network with storage) will be installed at GREEN-IPUC/PUCMinas, utilizing the lessons learned and experiences and the equipment developed at the Minas Gerais Arena do Jacare Stadium.","PeriodicalId":6649,"journal":{"name":"2014 IEEE 40th Photovoltaic Specialist Conference (PVSC)","volume":"67 1","pages":"2728-2733"},"PeriodicalIF":0.0000,"publicationDate":"2014-06-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE 40th Photovoltaic Specialist Conference (PVSC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PVSC.2014.6925493","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

This paper presents the design and studies performed in the first-phase implementation of the R&D project D308, in partnership with Energetic Company of Minas Gerais (CEMIG-D). The objective of this project is to evaluate the benefits and limitations of using storage with a grid-connected PV system. Specifically to evaluate injecting the energy stored in batteries charge by the PV into the electric grid in order to flatten the peak of the load curve of a feeder system (with evening peak-electricity consumption experienced in this area). The PV/storage system is being installed in the football stadium Arena do Jacare, located in Sete Lagoas, Minas Gerais. Initial studies have been performed to define the characteristics of the PV array, including surveys of the region characteristics, and solar resource/ climate data. Additionally, the characteristics of the optimum PV generator configuration and module technology have been evaluated, taking into consideration the stadium's limited available area and defined orientation--and the major design criterion to eliminate any shadow projection on photovoltaic modules that could reduce its performance. With the initial design of the PV generator structure and geometry, the system was performance was simuulated under projected conditions. An innovative feature of this project is a bidirectional conversion and connection unit, which has the capacity to store the energy coming from the PV generator and/or the electrical network in a battery bank. The unit can deliver the energy to the grid (a feeder operated by CEMIG in our tests) at specific defined times-such as the peak time in this area between 18:30 and 20:30. At the conclusion of this protype project, a larger scale of the system (photovoltaic system connected to the network with storage) will be installed at GREEN-IPUC/PUCMinas, utilizing the lessons learned and experiences and the equipment developed at the Minas Gerais Arena do Jacare Stadium.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
并网光伏储能系统的开发
本文介绍了与米纳斯吉拉斯州能源公司(CEMIG-D)合作的研发项目D308第一阶段实施的设计和研究。该项目的目的是评估与并网光伏系统一起使用储能的好处和局限性。具体而言,评估将光伏发电充电电池中储存的能量注入电网,以使馈线系统负荷曲线的峰值变平(该地区经历了晚高峰用电)。光伏/存储系统将安装在米纳斯吉拉斯州Sete Lagoas的Arena do Jacare足球场。已经进行了初步研究,以确定光伏阵列的特征,包括区域特征调查和太阳能资源/气候数据。此外,考虑到体育场有限的可用面积和确定的朝向,以及消除光伏模块上任何可能降低其性能的阴影投影的主要设计标准,对最佳光伏发电机配置和模块技术的特征进行了评估。在对光伏发电系统结构和几何形状进行初步设计的基础上,对系统在规划工况下的性能进行了仿真。该项目的一个创新之处是双向转换和连接单元,它有能力将来自光伏发电机和/或电网的能量存储在电池组中。该单元可以在特定的定义时间将能量输送到电网(在我们的测试中由CEMIG操作的馈线),例如该区域的高峰时间在18:30到20:30之间。在这个原型项目结束时,将利用在米纳斯吉拉斯州竞技场体育场开发的经验教训和设备,在GREEN-IPUC/PUCMinas安装更大规模的系统(光伏系统连接到带有存储的网络)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Rapid characterization of extended defects in III–V/Si by electron channeling contrast imaging Transport modeling of InGaN/GaN multiple quantum well solar cells Integration of PV into the energy system: Challenges and measures for generation and load management Determination of a minimum soiling level to affect photovoltaic devices Optical emission spectroscopy of High Power Impulse Magnetron Sputtering (HiPIMS) of CIGS thin films
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1