First Modelling Results of the EM Response of a CO2 Storage in the Paris Basin

B. Bourgeois, J. Girard
{"title":"First Modelling Results of the EM Response of a CO2 Storage in the Paris Basin","authors":"B. Bourgeois, J. Girard","doi":"10.2516/OGST/2009076","DOIUrl":null,"url":null,"abstract":"We study the feasibility of using electrical/EM methods for monitoring the injection of supercritical CO2 at a depth of 1700 m in a saline aquifer of the Paris Basin (Dogger carbonates). We first establish the theoretical interest of resistivity methods for CO2 monitoring through the basic laws of electrical physics in porous sedimentary rocks, assuming that supercritical CO2 is a perfect insulator. Various combinations of EM sources and sensors are discussed and it is shown that the best type of array consists of a galvanic source (i.e. injection of current via a pair of electrodes A and B) and of a grid of electric (and possibly magnetic) sensors at the ground surface. Given the usual depth and thinness of CO2 storage layers, current injection at depth was investigated in order to increase the current density in the reservoir and thus enhance the CO2 response. Point injection at the reservoir depth in the so-called “Mise A la Masse” (MAM) configuration is generally impossible in deep wells due to the presence of metallic casings. Therefore, the possibility of using a deep metallic casing as a long electrode distributing the current all along a borehole is studied. This kind of source is named “LEMAM” (Long Electrode Mise A la Masse) in order to differentiate it from the conventional MAM.Numerical simulations are presented for the LEMAM array and for the gradient or rectangle array (RECT), for which the current is injected by a pair of point electrodes at the ground surface. The geoelectric model used is based on an area close to the Saint-Martin-de-Bossenay (SMB) oilfield, in the south-east of the Paris Basin. The storage reservoir considered in this study is the 75-m-thick “Oolithe Blanche” formation (Mid Jurassic or Dogger, Bathonian age), located at a depth of about 1700 m below ground surface. In the models presented, the CO2 plume is simplified to a square horizontal slab of 2 km side, 70 m thick, floating at the top of the oolite aquifer. A uniform CO2 saturation of 80% is assumed, yielding a resistivity contrast of 25 with the initial reservoir.Two variants of the model with different reservoir resistivities are compared. The first model is calculated with a realistic reservoir resistivity of 20 ohm.m, reflecting the low salinity of the aquifer in this part of the Basin (≈ g g/L of NaCl). With this model, the time-lapse electric response of the CO2 plume is less than 0.5% of the initial electric field, which is below the estimated “repetition noise”. This poor result can be explained by the fact that the reservoir, in this case, is far from being the most conductive layer of the model. As a consequence, only a minor part of the injected current is used for energizing the CO2 plume: a rough calculation shows that only about 2% of the injected current crosses the reservoir, hence the poor response of the plume.A second model is calculated with an idealistic reservoir resistivity of 1 ohm.m, corresponding to about 50-70 g/L of NaCl in the aquifer (though such salinity is not observed anywhere in the Dogger aquifer of the Paris Basin, it is common in many storage aquifers). With this favourable model, it is estimated that about 30% of the injected current crosses the reservoir and energizes the plume, resulting in a time-lapse electric response as high as 6% of the initial field, which is quite measurable. For comparison, the timelapse electric response obtained with the same model for a surface current injection (RECT array) is only 2% of the initial field. With this same model, the time-lapse magnetic response obtained for the LEMAM injection is about 3% of the initial magnetic field.We conclude that the LEMAM array is very promising for the resistivity monitoring of a CO2 injection in a deep aquifer, provided that the water salinity is high enough for the reservoir to channel a significant fraction of the injected current (say > 10%).","PeriodicalId":19444,"journal":{"name":"Oil & Gas Science and Technology-revue De L Institut Francais Du Petrole","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2010-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"20","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Oil & Gas Science and Technology-revue De L Institut Francais Du Petrole","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2516/OGST/2009076","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 20

Abstract

We study the feasibility of using electrical/EM methods for monitoring the injection of supercritical CO2 at a depth of 1700 m in a saline aquifer of the Paris Basin (Dogger carbonates). We first establish the theoretical interest of resistivity methods for CO2 monitoring through the basic laws of electrical physics in porous sedimentary rocks, assuming that supercritical CO2 is a perfect insulator. Various combinations of EM sources and sensors are discussed and it is shown that the best type of array consists of a galvanic source (i.e. injection of current via a pair of electrodes A and B) and of a grid of electric (and possibly magnetic) sensors at the ground surface. Given the usual depth and thinness of CO2 storage layers, current injection at depth was investigated in order to increase the current density in the reservoir and thus enhance the CO2 response. Point injection at the reservoir depth in the so-called “Mise A la Masse” (MAM) configuration is generally impossible in deep wells due to the presence of metallic casings. Therefore, the possibility of using a deep metallic casing as a long electrode distributing the current all along a borehole is studied. This kind of source is named “LEMAM” (Long Electrode Mise A la Masse) in order to differentiate it from the conventional MAM.Numerical simulations are presented for the LEMAM array and for the gradient or rectangle array (RECT), for which the current is injected by a pair of point electrodes at the ground surface. The geoelectric model used is based on an area close to the Saint-Martin-de-Bossenay (SMB) oilfield, in the south-east of the Paris Basin. The storage reservoir considered in this study is the 75-m-thick “Oolithe Blanche” formation (Mid Jurassic or Dogger, Bathonian age), located at a depth of about 1700 m below ground surface. In the models presented, the CO2 plume is simplified to a square horizontal slab of 2 km side, 70 m thick, floating at the top of the oolite aquifer. A uniform CO2 saturation of 80% is assumed, yielding a resistivity contrast of 25 with the initial reservoir.Two variants of the model with different reservoir resistivities are compared. The first model is calculated with a realistic reservoir resistivity of 20 ohm.m, reflecting the low salinity of the aquifer in this part of the Basin (≈ g g/L of NaCl). With this model, the time-lapse electric response of the CO2 plume is less than 0.5% of the initial electric field, which is below the estimated “repetition noise”. This poor result can be explained by the fact that the reservoir, in this case, is far from being the most conductive layer of the model. As a consequence, only a minor part of the injected current is used for energizing the CO2 plume: a rough calculation shows that only about 2% of the injected current crosses the reservoir, hence the poor response of the plume.A second model is calculated with an idealistic reservoir resistivity of 1 ohm.m, corresponding to about 50-70 g/L of NaCl in the aquifer (though such salinity is not observed anywhere in the Dogger aquifer of the Paris Basin, it is common in many storage aquifers). With this favourable model, it is estimated that about 30% of the injected current crosses the reservoir and energizes the plume, resulting in a time-lapse electric response as high as 6% of the initial field, which is quite measurable. For comparison, the timelapse electric response obtained with the same model for a surface current injection (RECT array) is only 2% of the initial field. With this same model, the time-lapse magnetic response obtained for the LEMAM injection is about 3% of the initial magnetic field.We conclude that the LEMAM array is very promising for the resistivity monitoring of a CO2 injection in a deep aquifer, provided that the water salinity is high enough for the reservoir to channel a significant fraction of the injected current (say > 10%).
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
巴黎盆地二氧化碳储存库电磁响应的第一个模拟结果
我们研究了在巴黎盆地(Dogger碳酸盐)盐层1700米深处使用电/电磁方法监测超临界二氧化碳注入的可行性。我们首先从多孔沉积岩的电物理基本定律出发,假设超临界CO2是完美绝缘体,建立了电阻率法监测CO2的理论兴趣。讨论了电磁源和传感器的各种组合,结果表明,最佳的阵列类型由电源(即通过一对电极a和B注入电流)和地面上的电(可能还有磁)传感器网格组成。考虑到CO2储层通常的深度和厚度,为了增加储层中的电流密度,从而增强CO2响应,研究了深度注入电流的方法。在深井中,由于金属套管的存在,在所谓的“Mise A la Masse”(MAM)配置的油藏深度点注入通常是不可能的。因此,研究了利用深金属套管作为沿钻孔分布电流的长电极的可能性。这种源被命名为“LEMAM”(长电极Mise A la Masse),以区别于传统的MAM。给出了leam阵列和梯度或矩形阵列(RECT)的数值模拟,其中电流由地面上的一对点电极注入。所使用的地电模型是基于位于巴黎盆地东南部的Saint-Martin-de-Bossenay (SMB)油田附近的区域。本研究考虑的储层为75米厚的“Oolithe Blanche”组(中侏罗世或多格尔,Bathonian时代),位于地表以下约1700米的深度。在所提出的模型中,CO2羽流被简化为一个边长2公里、厚70米的方形水平板,漂浮在鲕粒含水层顶部。假设CO2均匀饱和度为80%,与初始储层的电阻率对比为25。对具有不同储层电阻率的两种模型进行了比较。第一个模型是用20欧姆的实际储层电阻率计算的。m,反映了该盆地部分含水层盐度较低(≈g g/L NaCl)。利用该模型,CO2羽流的时移电响应小于初始电场的0.5%,低于估计的“重复噪声”。这种糟糕的结果可以用这样一个事实来解释,即在这种情况下,储层远非模型中最导电的层。因此,只有一小部分注入电流被用于激励CO2羽流:粗略计算表明,只有约2%的注入电流穿过储层,因此羽流的响应很差。第二个模型以理想的储层电阻率为1欧姆计算。m,相当于含水层中约50-70 g/L的NaCl(尽管在巴黎盆地的Dogger含水层中没有任何地方观察到这种盐度,但在许多蓄水含水层中很常见)。在这种有利的模型下,估计大约30%的注入电流穿过储层并激活羽流,导致高达初始电场6%的延时电响应,这是相当可测量的。相比之下,使用相同模型的表面电流注入(RECT阵列)获得的时移电响应仅为初始场的2%。在相同的模型下,LEMAM注入的时移磁响应约为初始磁场的3%。我们得出的结论是,只要水的盐度足够高,使得储层能够引导相当一部分注入电流(例如> 10%),LEMAM阵列就非常有希望用于深层含水层二氧化碳注入的电阻率监测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Impact of geomechanical effects during SAGD process in a meander belt Flow Simulation Using Local Grid Refinements to Model Laminated Reservoirs Correlating Stochastically Distributed Reservoir Heterogeneities with Steam-Assisted Gravity Drainage Production Efficient estimation of hydrolyzed polyacrylamide (HPAM) solution viscosity for enhanced oil recovery process by polymer flooding Investigation of Asphaltene Adsorption onto Zeolite Beta Nanoparticles to Reduce Asphaltene Deposition in a Silica Sand Pack
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1