Comparison of rigid and deformable image registration accuracy of the liver during long-term transition after proton beam therapy

N. Fukumitsu, T. Terunuma, T. Okumura, H. Numajiri, K. Murofushi, K. Ohnishi, M. Mizumoto, T. Aihara, H. Ishikawa, Koji Tsuboi Hideyuki Sakurai
{"title":"Comparison of rigid and deformable image registration accuracy of the liver during long-term transition after proton beam therapy","authors":"N. Fukumitsu, T. Terunuma, T. Okumura, H. Numajiri, K. Murofushi, K. Ohnishi, M. Mizumoto, T. Aihara, H. Ishikawa, Koji Tsuboi Hideyuki Sakurai","doi":"10.14303/IMAGING-MEDICINE.1000078","DOIUrl":null,"url":null,"abstract":"Objective: To identify the previously irradiated region is important in re-irradiation. We investigated the long-term transition of geometrical accuracy of a commercially available rigid and deformable image registration (RIR, DIR) software product, MIM Maestro, in livers of patients who underwent proton beam therapy (PBT). Methods: Image registration of pre-treatment and post-treatment CT was performed in 15 liver tumor patients who received PBT and follow up post-treatment CT examination was performed over time (2-7 times each, a total of 54 times). We performed RIR and DIR of pre-treatment CT and compared the post-treatment CT by calculating the similarity of whole liver (Dice similarity coefficient: DSC) and dislocation of metallic markers implanted close to the tumor (fiducial registration error). Results: In the plain CT, the DSC was bigger with RIR in 1 case and DIR in 53 cases (0.83 ± 0.07 vs. 0.92 ± 0.04), then consistently bigger with DIR in 14 patients. The fiducial registration error was smaller with RIR in 10 cases, DIR in 43 cases, and equal error in 1 case (11.8 ± 6.9 vs. 7.6 ± 9.7 mm), then consistently smaller with DIR in 10 patients. In the contrast-enhanced CT, the DSC was consistently bigger with DIR in all 15 patients, 54 cases in all (0.84 ± 0.06 vs. 0.92 ± 0.03). The fiducial registration error was smaller with RIR in 7 cases and DIR in 47 cases (11.0 ± 6.3 vs. 6.3 ± 7.3 mm), then consistently smaller with DIR in 12 patients. Conclusion: The DIR performance of MIM is therefore superior to that of RIR and its advantage is independent the term after PBT.","PeriodicalId":13333,"journal":{"name":"Imaging in Medicine","volume":"16 1","pages":"149-154"},"PeriodicalIF":0.0000,"publicationDate":"2017-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Imaging in Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14303/IMAGING-MEDICINE.1000078","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Objective: To identify the previously irradiated region is important in re-irradiation. We investigated the long-term transition of geometrical accuracy of a commercially available rigid and deformable image registration (RIR, DIR) software product, MIM Maestro, in livers of patients who underwent proton beam therapy (PBT). Methods: Image registration of pre-treatment and post-treatment CT was performed in 15 liver tumor patients who received PBT and follow up post-treatment CT examination was performed over time (2-7 times each, a total of 54 times). We performed RIR and DIR of pre-treatment CT and compared the post-treatment CT by calculating the similarity of whole liver (Dice similarity coefficient: DSC) and dislocation of metallic markers implanted close to the tumor (fiducial registration error). Results: In the plain CT, the DSC was bigger with RIR in 1 case and DIR in 53 cases (0.83 ± 0.07 vs. 0.92 ± 0.04), then consistently bigger with DIR in 14 patients. The fiducial registration error was smaller with RIR in 10 cases, DIR in 43 cases, and equal error in 1 case (11.8 ± 6.9 vs. 7.6 ± 9.7 mm), then consistently smaller with DIR in 10 patients. In the contrast-enhanced CT, the DSC was consistently bigger with DIR in all 15 patients, 54 cases in all (0.84 ± 0.06 vs. 0.92 ± 0.03). The fiducial registration error was smaller with RIR in 7 cases and DIR in 47 cases (11.0 ± 6.3 vs. 6.3 ± 7.3 mm), then consistently smaller with DIR in 12 patients. Conclusion: The DIR performance of MIM is therefore superior to that of RIR and its advantage is independent the term after PBT.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
质子束治疗后肝脏长期过渡期间刚性与变形图像配准精度的比较
目的:明确前辐照区在再辐照中的重要作用。我们研究了商业上可用的刚性和可变形图像配准(RIR, DIR)软件产品MIM Maestro在接受质子束治疗(PBT)的患者肝脏中的几何精度的长期转变。方法:对15例肝肿瘤患者行PBT治疗前后CT图像配准,并随访治疗后CT检查(各2 ~ 7次,共54次)。我们对治疗前CT进行RIR和DIR,并通过计算全肝的相似度(Dice similarity coefficient: DSC)和靠近肿瘤植入的金属标记物的错位度(基准点配准误差)来比较治疗后CT。结果:CT平扫中,1例DSC随RIR增大,53例DSC随DIR增大(0.83±0.07∶0.92±0.04),14例DSC随DIR增大。10例RIR患者的基准登记误差较小,43例DIR患者的基准登记误差较小,1例误差相等(11.8±6.9 vs. 7.6±9.7 mm), 10例DIR患者的基准登记误差一致较小。15例患者均有54例(0.84±0.06比0.92±0.03),增强CT显示DSC均大于DIR。7例RIR和47例DIR的基准登记误差较小(11.0±6.3 vs. 6.3±7.3 mm), 12例DIR的基准登记误差一致较小。结论:MIM的DIR性能优于RIR,且其优势在PBT后独立。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Nasal NK/T-cell lymphoma: Clinical features and dermoscopic appearances Cardiac Metastasis In A Patient With Poorly-differentiated Neuroendorcrine Tumor: 18F-FDG PET-CT Finding Carcinoma of tongue in xeroderma pigmentosum a medical image Saffron Extract Prevents Vancomycin-induced Nephrotoxicity Genital Self-mutilation In Schizophreni
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1