Three-dimensional Measuring of Zygomaticomaxillary Complex Symmetry after Fixation of Unilateral Zygomaticomaxillary Complex Fracture

Mahetab Montaser, F. Khalifa, F. Mohamed, W. Shawkat
{"title":"Three-dimensional Measuring of Zygomaticomaxillary Complex Symmetry after Fixation of Unilateral Zygomaticomaxillary Complex Fracture","authors":"Mahetab Montaser, F. Khalifa, F. Mohamed, W. Shawkat","doi":"10.21608/adjg.2021.64304.1342","DOIUrl":null,"url":null,"abstract":"Purpose: to evaluate the symmetry of the reduced unilateral zygomaticomaxillary complex (ZMC) fractures fixed with computer designed custom machined titanium miniplate and conventional titanium miniplate, using three dimensional computed tomography (3D-CT) analysis of ZMC position. Patients and Methods: Ten patients who suffered from unilateral ZMC fractured were involved in this study. The patients were randomly and equally divided into two groups. In group A, the ZMC fractures were reduced and fixed with computer designed custom machined titanium miniplates, whereas in group B, they were fixed by conventional 2.0mm titanium miniplates. Computed Tomography (CT) scan was performed for each patient pre and postoperatively, then imported as a Digital imaging communication in medicine (DICOM) to MIMICS software to make Standard tessellation language(STL) file for quantitative measurements, preoperative surgical planning was performed to group A for designing of custom made plates by mirror imaging of the unaffected side, segmentation and virtual reduction using PlastyCAD software, then fabrication of the final design of the plate by Computer numerically controlled (CNC) milling machines. Results: Clinical symmetry was achieved in all cases except two in group B. By radiographic analysis, there was a significant difference between the two groups. Group A showed smaller deviation from the unaffected side, indicating more adequate reduction in group A than group B. Conclusion: Custom made plate revealed adequate accuracy in restoring ZMC symmetry than conventional miniplates. The 3-D quantitative assessment used in this study successfully reflected symmetry levels Codex : 14/22.01 azhardentj@azhar.edu.eg http://adjg.journals.ekb.eg DOI: 10.21608/adjg.2021.64304.1342 Oral Medicine & Surgical Sciences (Oral Medicine, Oral & Maxillofacial Surgery, Oral Pathology, Oral Biology)","PeriodicalId":7493,"journal":{"name":"Al-Azhar Dental Journal for Girls","volume":"5 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Al-Azhar Dental Journal for Girls","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21608/adjg.2021.64304.1342","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Purpose: to evaluate the symmetry of the reduced unilateral zygomaticomaxillary complex (ZMC) fractures fixed with computer designed custom machined titanium miniplate and conventional titanium miniplate, using three dimensional computed tomography (3D-CT) analysis of ZMC position. Patients and Methods: Ten patients who suffered from unilateral ZMC fractured were involved in this study. The patients were randomly and equally divided into two groups. In group A, the ZMC fractures were reduced and fixed with computer designed custom machined titanium miniplates, whereas in group B, they were fixed by conventional 2.0mm titanium miniplates. Computed Tomography (CT) scan was performed for each patient pre and postoperatively, then imported as a Digital imaging communication in medicine (DICOM) to MIMICS software to make Standard tessellation language(STL) file for quantitative measurements, preoperative surgical planning was performed to group A for designing of custom made plates by mirror imaging of the unaffected side, segmentation and virtual reduction using PlastyCAD software, then fabrication of the final design of the plate by Computer numerically controlled (CNC) milling machines. Results: Clinical symmetry was achieved in all cases except two in group B. By radiographic analysis, there was a significant difference between the two groups. Group A showed smaller deviation from the unaffected side, indicating more adequate reduction in group A than group B. Conclusion: Custom made plate revealed adequate accuracy in restoring ZMC symmetry than conventional miniplates. The 3-D quantitative assessment used in this study successfully reflected symmetry levels Codex : 14/22.01 azhardentj@azhar.edu.eg http://adjg.journals.ekb.eg DOI: 10.21608/adjg.2021.64304.1342 Oral Medicine & Surgical Sciences (Oral Medicine, Oral & Maxillofacial Surgery, Oral Pathology, Oral Biology)
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
单侧颧上颌复合体骨折固定后颧上颌复合体对称性的三维测量
目的:利用三维计算机断层扫描(3D-CT)对单侧颧腋复合体(ZMC)骨折的位置进行分析,评价计算机设计的定制微型机械钛板与常规微型钛板固定的对称性。患者与方法:10例单侧ZMC骨折患者。患者随机平均分为两组。A组采用计算机设计的定制加工微型钛板复位固定ZMC骨折,B组采用常规2.0mm微型钛板固定ZMC骨折。术前、术后对每位患者进行CT扫描,将其作为医学数字成像通信(DICOM)导入MIMICS软件,制作标准细分语言(STL)文件进行定量测量,术前对a组进行手术规划,利用PlastyCAD软件对未受影响侧进行镜像、分割、虚拟还原,设计定制钢板。然后通过计算机数控铣床加工最终设计的板材。结果:除b组2例外,其余病例均达到临床对称。经x线分析,两组间差异有统计学意义。A组与未受影响侧的偏差较小,表明A组复位比b组更充分。结论:定制钢板比常规微型钢板在恢复ZMC对称性方面具有足够的准确性。本研究中使用的三维定量评估成功地反映了对称水平。Codex: 14/22.01 azhardentj@azhar.edu.eg http://adjg.journals.ekb.eg DOI: 10.21608/adjg.2021.64304.1342口腔医学与外科科学(口腔医学,口腔颌面外科,口腔病理学,口腔生物学)
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Efficacy of Aloe vera in Treatment of Experimentally Induced Oral Lichenoid Reaction Evaluation of Local Versus Intravenous Administration of Adipose Tissue-Derived Stem Cells on Regeneration of Oral Epithelium of Chemotherapy Treated Rats The Influence of Different Implant Abutment Sizes on Fracture Resistance of Two Monolithic Ceramic Crown Systems Effect of Irradiation with 980-nm Diode Laser on the Microhardness of Young and Old Root Canal Dentin after Treatment with Chemical Solutions Evaluation of Occlusal Pressure Pattern and Dimensional Changes of the Lined Dentures Subjected to Microwave Disinfection Protocol
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1