The assessment of consecutive 4D-CT scans during simulation for lung stereotactic body radiation therapy patients

IF 0.7 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Polish Journal of Medical Physics and Engineering Pub Date : 2020-12-01 DOI:10.2478/pjmpe-2020-0023
M. Savanović, B. Štrbac, D. Jaroš, J. Foulquier
{"title":"The assessment of consecutive 4D-CT scans during simulation for lung stereotactic body radiation therapy patients","authors":"M. Savanović, B. Štrbac, D. Jaroš, J. Foulquier","doi":"10.2478/pjmpe-2020-0023","DOIUrl":null,"url":null,"abstract":"Abstract Purpose: To evaluate the breathing amplitude, tumor motion, patient positioning, and treatment volumes among consecutive four-dimensional computed tomography (4D-CT) scans, during the simulation for lung stereotactic body radiation therapy (SBRT). Material and methods: The variation and shape of the breathing amplitude, patient positioning, and treatment volumes were evaluated for 55 lung cancer patients after consecutive 4D-CT acquisitions, scanned at one-week intervals. The impact of variation in the breathing amplitude on lung tumor motion was determined for 20 patients. The gross tumor volume (GTV) was contoured from a free-breathing CT scan and at ten phases of the respiratory cycle, for both 4D-CTs (440 phases in total). Results: Breathing amplitude decreased by 3.6 (3.4-4.9) mm, tumor motion by 3.2 (0.4-5.0) mm while breathing period increased by 4 (2-6) s, inter-scan for 20 patients. Intra-scan variation was 4 times greater for the breathing amplitude, 5 times for the breathing period, and 8 times for the breathing cycle, comparing irregular versus regular breathing patterns for 55 patients. Using coaching, the breathing amplitude increases 3 to 8 mm, and the breathing period 2 to 6 s. Differences in the contoured treatment volumes were less than 10% between consecutive scans. Patient positioning remained stable, with a small inter-scan difference of 1.1 (0.6-1.4) mm. Conclusion: Decreasing the inter-scan breathing amplitude decreases the tumor motion reciprocally. When the breathing amplitude decreases, the breathing period increases at inter- and intra-scan, especially during irregular breathing. Coaching improves respiration, keeping the initial shape of the breathing amplitude. Contoured treatment volumes and patient positioning were reproducible through successive scans.","PeriodicalId":53955,"journal":{"name":"Polish Journal of Medical Physics and Engineering","volume":"16 3 1","pages":"193 - 199"},"PeriodicalIF":0.7000,"publicationDate":"2020-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Polish Journal of Medical Physics and Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/pjmpe-2020-0023","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 1

Abstract

Abstract Purpose: To evaluate the breathing amplitude, tumor motion, patient positioning, and treatment volumes among consecutive four-dimensional computed tomography (4D-CT) scans, during the simulation for lung stereotactic body radiation therapy (SBRT). Material and methods: The variation and shape of the breathing amplitude, patient positioning, and treatment volumes were evaluated for 55 lung cancer patients after consecutive 4D-CT acquisitions, scanned at one-week intervals. The impact of variation in the breathing amplitude on lung tumor motion was determined for 20 patients. The gross tumor volume (GTV) was contoured from a free-breathing CT scan and at ten phases of the respiratory cycle, for both 4D-CTs (440 phases in total). Results: Breathing amplitude decreased by 3.6 (3.4-4.9) mm, tumor motion by 3.2 (0.4-5.0) mm while breathing period increased by 4 (2-6) s, inter-scan for 20 patients. Intra-scan variation was 4 times greater for the breathing amplitude, 5 times for the breathing period, and 8 times for the breathing cycle, comparing irregular versus regular breathing patterns for 55 patients. Using coaching, the breathing amplitude increases 3 to 8 mm, and the breathing period 2 to 6 s. Differences in the contoured treatment volumes were less than 10% between consecutive scans. Patient positioning remained stable, with a small inter-scan difference of 1.1 (0.6-1.4) mm. Conclusion: Decreasing the inter-scan breathing amplitude decreases the tumor motion reciprocally. When the breathing amplitude decreases, the breathing period increases at inter- and intra-scan, especially during irregular breathing. Coaching improves respiration, keeping the initial shape of the breathing amplitude. Contoured treatment volumes and patient positioning were reproducible through successive scans.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
肺立体定向放射治疗患者模拟过程中连续4D-CT扫描的评估
目的:评估肺立体定向放射治疗(SBRT)模拟过程中连续四维计算机断层扫描(4D-CT)的呼吸幅度、肿瘤运动、患者体位和治疗量。材料与方法:对55例肺癌患者进行连续4D-CT扫描,每隔一周扫描一次,评估其呼吸幅度的变化和形状、患者体位和治疗量。研究了20例患者呼吸幅度变化对肺肿瘤运动的影响。从自由呼吸CT扫描和呼吸周期的10个阶段绘制总肿瘤体积(GTV),用于两种4d -CT(共440期)。结果:20例患者呼吸幅值下降3.6 (3.4 ~ 4.9)mm,肿瘤运动3.2 (0.4 ~ 5.0)mm,呼吸周期增加4 (2 ~ 6)s。在55例患者中,比较不规则呼吸模式和规则呼吸模式,扫描内呼吸振幅的变化是正常呼吸模式的4倍,呼吸周期的变化是正常呼吸模式的5倍,呼吸周期的变化是正常呼吸模式的8倍。使用指导时,呼吸幅度增加3 ~ 8mm,呼吸周期2 ~ 6s。在连续扫描之间,轮廓治疗量的差异小于10%。患者体位保持稳定,扫描间差异较小,仅为1.1 (0.6-1.4)mm。结论:降低扫描间呼吸幅值可减少肿瘤运动。当呼吸幅度减小时,扫描间和扫描内的呼吸周期增加,尤其是在不规则呼吸时。训练改善呼吸,保持呼吸振幅的初始形状。通过连续扫描可重现轮廓治疗量和患者体位。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Polish Journal of Medical Physics and Engineering
Polish Journal of Medical Physics and Engineering RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
1.30
自引率
0.00%
发文量
19
期刊介绍: Polish Journal of Medical Physics and Engineering (PJMPE) (Online ISSN: 1898-0309; Print ISSN: 1425-4689) is an official publication of the Polish Society of Medical Physics. It is a peer-reviewed, open access scientific journal with no publication fees. The issues are published quarterly online. The Journal publishes original contribution in medical physics and biomedical engineering.
期刊最新文献
Parametrization of subsegmental infarcts using high spatial resolution 2DSTE and synthetic ultrasonic data Automated differential diagnostics of respiratory diseases using an electronic stethoscope Evaluating the impact of anatomical changes on dose distributions in head and neck cancer Comparing eDQE and eNEQ metrics – is there an alternative approach to assessing image quality in digital mammography? Vascular stiffness in cold pressor test hyper-reactors
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1