{"title":"Preparation and Application of Tetracycline Hydrochloride Liquid membrane Electrodes.","authors":"A. M. Abass","doi":"10.22401/JNUS.21.2.11","DOIUrl":null,"url":null,"abstract":"Two liquid membrane electrodes for (TCH) were prepared by using ion pair which included phosphomolybdic acid (PMA)-(TCH) with plasticizers: Di-n-butyl phthalate(DBPH), and di-octylphenylphosphonate (DOPH). Tetracycline electrodes were gave a Nernstain response equal to 56. 51 and 50. 66 mV/decade for membranes depended on DBPH and DOPH as a plastisizers, respectively. Linear ranges were around 6. 8×10-6- 1. 0×10-1 and 1. 0×10-5-1. 0×10-1 M, respectively. Detection limit were equal to 4. 0×10-6, 5. 0×10-6 M, respectively. PH range were also studied at three different concentration of tetracycline solutions. As well as were studied lifetime, selectivity, potentiometric methods such as direct, standard addition , multiple standard addition and titration methods were applied to determination tetracycline in pharmaceutical preparation","PeriodicalId":14922,"journal":{"name":"Journal of Al-Nahrain University-Science","volume":"79 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2018-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Al-Nahrain University-Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22401/JNUS.21.2.11","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10
Abstract
Two liquid membrane electrodes for (TCH) were prepared by using ion pair which included phosphomolybdic acid (PMA)-(TCH) with plasticizers: Di-n-butyl phthalate(DBPH), and di-octylphenylphosphonate (DOPH). Tetracycline electrodes were gave a Nernstain response equal to 56. 51 and 50. 66 mV/decade for membranes depended on DBPH and DOPH as a plastisizers, respectively. Linear ranges were around 6. 8×10-6- 1. 0×10-1 and 1. 0×10-5-1. 0×10-1 M, respectively. Detection limit were equal to 4. 0×10-6, 5. 0×10-6 M, respectively. PH range were also studied at three different concentration of tetracycline solutions. As well as were studied lifetime, selectivity, potentiometric methods such as direct, standard addition , multiple standard addition and titration methods were applied to determination tetracycline in pharmaceutical preparation