Thomas E. Sarvey, Yang Zhang, Yue Zhang, Hanju Oh, M. Bakir
{"title":"Thermal and electrical effects of staggered micropin-fin dimensions for cooling of 3D microsystems","authors":"Thomas E. Sarvey, Yang Zhang, Yue Zhang, Hanju Oh, M. Bakir","doi":"10.1109/ITHERM.2014.6892283","DOIUrl":null,"url":null,"abstract":"Microfluidic cooling shows promise in cooling next generation 3D microsystems when integrated with through-silicon-vias. In this work, electrical and thermal effects of staggered micropin-fin heat sink dimensions are analyzed using deionized water. An experimental study of five different silicon micropin-fin arrays with a nominal height of 200 μm and diameters down to 30 μm was conducted at flow rates up to approximately 100mL/min and pressure drops up to approximately 200 kPa. The lowest convective thermal resistance achieved was 0.098 °C/W across a 1 cm2 die. These experimental results were then used to simulate temperature profiles of an interposer-cooled 3D stack.","PeriodicalId":12453,"journal":{"name":"Fourteenth Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (ITherm)","volume":"62 1","pages":"205-212"},"PeriodicalIF":0.0000,"publicationDate":"2014-09-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"21","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fourteenth Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (ITherm)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ITHERM.2014.6892283","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 21
Abstract
Microfluidic cooling shows promise in cooling next generation 3D microsystems when integrated with through-silicon-vias. In this work, electrical and thermal effects of staggered micropin-fin heat sink dimensions are analyzed using deionized water. An experimental study of five different silicon micropin-fin arrays with a nominal height of 200 μm and diameters down to 30 μm was conducted at flow rates up to approximately 100mL/min and pressure drops up to approximately 200 kPa. The lowest convective thermal resistance achieved was 0.098 °C/W across a 1 cm2 die. These experimental results were then used to simulate temperature profiles of an interposer-cooled 3D stack.