{"title":"Removal of NO/sub x/ using discharges by pulsed power","authors":"H. Akiyama, K. Kawamura, T. Takeshita, S. Katsuki, S. Maeda, S. Tsukamoto, M. Murata","doi":"10.1109/PPC.1995.596469","DOIUrl":null,"url":null,"abstract":"Pollution control is one of important subjects in the world. Such pollution control by pulsed power is a promising method for the removal of NO/sub x/ and SO/sub 2/. Experimental results of NO/sub x/ removal by a repetitive pulsed power generator using an inductive energy storage system are described. The removal ratio of NO gas was measured by a gas analyzer and a laser-induced fluorescence (LIF) method. The NO gas, mixed with N/sub 2/ gas was removed up to about 100%, and the dependence of the removal ratio of NO gas on the shot number of pulsed power is in good agreement with results of computer simulation.","PeriodicalId":11163,"journal":{"name":"Digest of Technical Papers. Tenth IEEE International Pulsed Power Conference","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1995-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Digest of Technical Papers. Tenth IEEE International Pulsed Power Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PPC.1995.596469","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

Abstract

Pollution control is one of important subjects in the world. Such pollution control by pulsed power is a promising method for the removal of NO/sub x/ and SO/sub 2/. Experimental results of NO/sub x/ removal by a repetitive pulsed power generator using an inductive energy storage system are described. The removal ratio of NO gas was measured by a gas analyzer and a laser-induced fluorescence (LIF) method. The NO gas, mixed with N/sub 2/ gas was removed up to about 100%, and the dependence of the removal ratio of NO gas on the shot number of pulsed power is in good agreement with results of computer simulation.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
脉冲功率放电去除NO/ subx /
污染控制是当今世界的重要课题之一。这种脉冲功率污染控制是去除NO/sub x/和SO/sub 2/的一种很有前途的方法。本文描述了利用电感储能系统的重复脉冲功率发生器去除NO/sub x/的实验结果。采用气体分析仪和激光诱导荧光(LIF)法测定NO气体去除率。与N/ sub2 /气体混合后的NO气体去除率可达100%左右,且NO气体去除率随脉冲功率发射次数的变化规律与计算机模拟结果吻合较好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Modeling of DM1 POS and load performance Investigations of compact high-current accelerators RADAN-303 synchronization with nanosecond accuracy Experimental results from a coaxial virtual cathode oscillator The 67 MJ, 50 kV capacitor bank for the high-power iodine laser of the facility ISKRA-5: description and experience An investigation of trigatron breakdown by two different mechanisms
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1