X-ray spectrometry applied for determination of linear attenuation coefficient of polymer-based samples as radiologically tissue-equivalent materials

Gisell Ruiz Boiset, Renne Rodrigues Rosinelli, G. Freire, Raissa Aline Santos Moura, Raphael Moratta, E. Yoshimura, P. Costa
{"title":"X-ray spectrometry applied for determination of linear attenuation coefficient of polymer-based samples as radiologically tissue-equivalent materials","authors":"Gisell Ruiz Boiset, Renne Rodrigues Rosinelli, G. Freire, Raissa Aline Santos Moura, Raphael Moratta, E. Yoshimura, P. Costa","doi":"10.15392/2319-0612.2023.2166","DOIUrl":null,"url":null,"abstract":"In this work we obtained experimental linear attenuation coefficients of polymer-based samples at diagnostic imaging energy range (15-150 keV) for eleven formulations candidates for tissue-equivalent materials (TEMs). TEMs is any material that simulates a human body part or human tissue in its interaction with radiation. In diagnostic radiology,  the maximum difference between the linear attenuation coefficient of the TEMs and the target material should be no more than 5% in the energy range of interest. A polienergetic narrow beam was obtained using a tungsten target x-ray tube and CdTe detector. The densities of the samples were determined and compared with reference materials obtaining a maximum difference of 17%. The comparisons between the  linear attenuation coefficient of the formulations and the respective reference materials for which they were initially designed, has demonstrated good correspondence over a wide energy range. Energy ranges in which the developed samples simulate other human tissues in addition to those initially considered were found, taken into account the criterion that the maximum difference between the linear attenuation coefficients does not exceed 5% is met. The results emphasize the possibility of production and characterization of TEMs to be used in the construction of imaging and dosimetry phantoms.","PeriodicalId":9203,"journal":{"name":"Brazilian Journal of Radiation Sciences","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-05-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Brazilian Journal of Radiation Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15392/2319-0612.2023.2166","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In this work we obtained experimental linear attenuation coefficients of polymer-based samples at diagnostic imaging energy range (15-150 keV) for eleven formulations candidates for tissue-equivalent materials (TEMs). TEMs is any material that simulates a human body part or human tissue in its interaction with radiation. In diagnostic radiology,  the maximum difference between the linear attenuation coefficient of the TEMs and the target material should be no more than 5% in the energy range of interest. A polienergetic narrow beam was obtained using a tungsten target x-ray tube and CdTe detector. The densities of the samples were determined and compared with reference materials obtaining a maximum difference of 17%. The comparisons between the  linear attenuation coefficient of the formulations and the respective reference materials for which they were initially designed, has demonstrated good correspondence over a wide energy range. Energy ranges in which the developed samples simulate other human tissues in addition to those initially considered were found, taken into account the criterion that the maximum difference between the linear attenuation coefficients does not exceed 5% is met. The results emphasize the possibility of production and characterization of TEMs to be used in the construction of imaging and dosimetry phantoms.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
应用x射线光谱法测定作为放射学组织等效材料的聚合物基样品线性衰减系数
在这项工作中,我们获得了11种候选组织等效材料(tem)配方在诊断成像能量范围(15-150 keV)下聚合物基样品的实验线性衰减系数。tem是任何模拟人体部位或人体组织与辐射相互作用的材料。在诊断放射学中,tem和目标材料的线性衰减系数之间的最大差值在感兴趣的能量范围内应不超过5%。利用钨靶x射线管和碲化镉探测器获得了一束高能窄光束。测定了样品的密度,并与标准物质进行了比较,最大差异为17%。通过比较配方的线性衰减系数与最初设计配方的参考物质的线性衰减系数,发现在较宽的能量范围内具有良好的对应关系。考虑到线性衰减系数之间的最大差异不超过5%的标准,发现开发样品模拟除最初考虑的那些人体组织之外的其他人体组织的能量范围。该结果强调了用于成像和剂量学模型构建的tem的生产和表征的可能性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Análisis integral de visitas guiadas al reactor de investigación nuclear RA-6: perspectivas educativas, de investigación y sociales Development of a sample exchange system for irradiations in the BH-3 channel of the IEA-R1 reactor at IPEN Análise dos índices de exposição de exames de radiografia digital Multiphysics Computational Modeling of Nuclear Reactors Small Size Through the Coupling of Serpent Codes and Fluent Abordagens de blindagens baseadas em polímeros como uma solução prática na redução dos riscos radiológicos em operações de campo
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1