SARS-CoV-2 Detection: Fast and Cost-Effective Sample Processing Prior to RT-PCR

C. Salvador-García, Maria Dolores Ocete-Mochon, Rafael Medina-Gonzalez, Begoña Fuster-Escrivá, Sonia Cortes-Badenes, Maria Carmen Breso-Vila, Maria Jose Lahiguera-Abalos, C. Gimeno-Cardona
{"title":"SARS-CoV-2 Detection: Fast and Cost-Effective Sample Processing Prior to RT-PCR","authors":"C. Salvador-García, Maria Dolores Ocete-Mochon, Rafael Medina-Gonzalez, Begoña Fuster-Escrivá, Sonia Cortes-Badenes, Maria Carmen Breso-Vila, Maria Jose Lahiguera-Abalos, C. Gimeno-Cardona","doi":"10.11648/J.IJBECS.20210702.13","DOIUrl":null,"url":null,"abstract":"The pandemic COVID-19 needs a rapid microbiological diagnostic from Clinical Microbiology Units. Due to the fact that it is done by using a reverse transcription polymerase chain reaction (rRT-PCR) previous RNA extraction and automated equipment and reagents for RNA extraction represent an economic increase to the diagnosis, we describe an easy, cost-effective and fast alternative extraction-free SARS-CoV-2. Samples were treated with proteinase K for 10 minutes at 55°C. Then, there is a heat-process for 5 minutes at 98°C and finally, 3 minutes at -20°C before a commercial-commonly-used rRT-PCR procedure. The RNA automated-extraction was also performed with QIAsymphony RNA Kit (Qiagen) equipment. A total of 220 nasopharyngeal and oropharyngeal swabs were analyzed. 113 samples were tested positive whereas 106 samples were tested negative with RNA automated-extraction and extraction-free method, for an agreement of 99%. A total of one discordant sample was noted in which no amplified result (gene ORF1ab and N) were observed by RNA automated-extraction and gene ORF1ab (Ct 39) and gene N (Ct 37) by extraction-free. Thus, results were comparable with automated-extraction. This method is not only clinically acceptable but also confers an easy, fast, and cost-effective alternative to automated-extraction. Therefore, microbiological laboratories, with low economics resources and/or without automated-extraction equipment, could incorporate it.","PeriodicalId":73426,"journal":{"name":"International journal of biomedical engineering and clinical science","volume":"16 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-06-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of biomedical engineering and clinical science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11648/J.IJBECS.20210702.13","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The pandemic COVID-19 needs a rapid microbiological diagnostic from Clinical Microbiology Units. Due to the fact that it is done by using a reverse transcription polymerase chain reaction (rRT-PCR) previous RNA extraction and automated equipment and reagents for RNA extraction represent an economic increase to the diagnosis, we describe an easy, cost-effective and fast alternative extraction-free SARS-CoV-2. Samples were treated with proteinase K for 10 minutes at 55°C. Then, there is a heat-process for 5 minutes at 98°C and finally, 3 minutes at -20°C before a commercial-commonly-used rRT-PCR procedure. The RNA automated-extraction was also performed with QIAsymphony RNA Kit (Qiagen) equipment. A total of 220 nasopharyngeal and oropharyngeal swabs were analyzed. 113 samples were tested positive whereas 106 samples were tested negative with RNA automated-extraction and extraction-free method, for an agreement of 99%. A total of one discordant sample was noted in which no amplified result (gene ORF1ab and N) were observed by RNA automated-extraction and gene ORF1ab (Ct 39) and gene N (Ct 37) by extraction-free. Thus, results were comparable with automated-extraction. This method is not only clinically acceptable but also confers an easy, fast, and cost-effective alternative to automated-extraction. Therefore, microbiological laboratories, with low economics resources and/or without automated-extraction equipment, could incorporate it.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
SARS-CoV-2检测:RT-PCR前快速和经济有效的样品处理
COVID-19大流行需要临床微生物学单位的快速微生物学诊断。由于它是通过使用逆转录聚合酶链反应(rRT-PCR)之前的RNA提取和RNA提取的自动化设备和试剂来完成的,这代表了诊断的经济增长,我们描述了一种简单,经济且快速的替代无提取的SARS-CoV-2。样品用蛋白酶K在55℃下处理10分钟。然后,在98°C下加热5分钟,最后在-20°C下加热3分钟,然后进行商业常用的rRT-PCR程序。采用QIAsymphony RNA Kit (Qiagen)设备进行RNA自动提取。对220份鼻咽拭子和口咽拭子进行分析。RNA自动提取法和无提取法检测阳性113份,阴性106份,一致性为99%。共有1份不一致样本,RNA自动提取未观察到扩增结果(ORF1ab基因和N基因),无提取ORF1ab基因(Ct 39)和N基因(Ct 37)。因此,结果与自动提取具有可比性。该方法不仅在临床上可接受,而且为自动提取提供了一种简单、快速、经济的替代方法。因此,经济资源低和/或没有自动提取设备的微生物实验室可以采用它。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Safety Evaluation of Recombinant Bovine Lactoferrin as a Novel Biomaterial Determinants of Neonatal Outcomes for Preterm Infants Admitted to the Neonatal Intensive Care Unit at Ndola Teaching Hospital in Ndola District, Zambia Predicative Meaning of Radioiodine Pharmacokinetics Indices for Evaluation of Radioablation Efficacy of Thyroid Residuum in Patients with Differentiated Thyroid Cancer Epidemiology and Diagnostic Methods of Foot-and-Mouth Disease: A Review The Effectiveness of Three-Dimensional Planning and Augmented Reality Navigation-Assisted Total Hip Arthroplasty: A Systematic Review and Meta-Analysis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1