{"title":"Design and analysis of an innovative combined magneto-rheological damper-mount","authors":"D. Phu, Jye Ung Chung, Seung-bok Choi","doi":"10.1117/12.2083810","DOIUrl":null,"url":null,"abstract":"In this paper, a new innovative modified high-loaded magneto-rheological fluid (MR in short) damper-mount is presented. The proposed damper-mount is designed based on two modes of MR fluid such as flow mode and shear mode, and it includes two separated electric coil for establishing magnetic field. The damping force of the damper-mount is analyzed based on the difference pressure between upper chamber and lower chamber. After analyzing the mathematical function of damping force, the proposed mount is optimized following the maximal damping force by using ANSYS software. Besides, there is a laboratorial MR fluid using in this optimization such as plate-like fluid MRF140. Results of optimization show that the requirement of damping force is obtain and the saturation of materials is in range of limitation.","PeriodicalId":51155,"journal":{"name":"Smart Structures and Systems","volume":"21 1","pages":""},"PeriodicalIF":2.2000,"publicationDate":"2015-04-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Smart Structures and Systems","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1117/12.2083810","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
引用次数: 6
Abstract
In this paper, a new innovative modified high-loaded magneto-rheological fluid (MR in short) damper-mount is presented. The proposed damper-mount is designed based on two modes of MR fluid such as flow mode and shear mode, and it includes two separated electric coil for establishing magnetic field. The damping force of the damper-mount is analyzed based on the difference pressure between upper chamber and lower chamber. After analyzing the mathematical function of damping force, the proposed mount is optimized following the maximal damping force by using ANSYS software. Besides, there is a laboratorial MR fluid using in this optimization such as plate-like fluid MRF140. Results of optimization show that the requirement of damping force is obtain and the saturation of materials is in range of limitation.
期刊介绍:
An International Journal of Mechatronics, Sensors, Monitoring, Control, Diagnosis, and Management airns at providing a major publication channel for researchers in the general area of smart structures and systems. Typical subjects considered by the journal include:
Sensors/Actuators(Materials/devices/ informatics/networking)
Structural Health Monitoring and Control
Diagnosis/Prognosis
Life Cycle Engineering(planning/design/ maintenance/renewal)
and related areas.