Osteogenic parameters surrounding trabecular tantalum metal implants in osteotomies prepared via osseodensification drilling

L. Witek, Adham Alifarag, N. Tovar, Christopher D Lopez, L. Gil, M. Gorbonosov, Kaitlin Hannan, R. Neiva, P. Coelho
{"title":"Osteogenic parameters surrounding trabecular tantalum metal implants in osteotomies prepared via osseodensification drilling","authors":"L. Witek, Adham Alifarag, N. Tovar, Christopher D Lopez, L. Gil, M. Gorbonosov, Kaitlin Hannan, R. Neiva, P. Coelho","doi":"10.4317/medoral.23108","DOIUrl":null,"url":null,"abstract":"Background Surgical fixation of implants into bone for the correction of bone deformities or defects is a traditional approach for skeletal stabilization. Important measures of efficacy of implants include implant stability and osseointegration—the direct interaction between living bone and an implant. Osseointegration depends on successful implant placement and subsequent bone remodeling. This study utilized osseodensification drilling (OD) in a low bone density model using trabecular metal (TM) implants. Material and Methods Three osteotomy sites, Regular, OD-CW (clockwise), and OD-CCW (counterclockwise), were prepared in each ilium of three female sheep. Drilling was performed at 1100rpm with saline irrigation. Trabecular metal (TM) (Zimmer®, Parsippany, NJ, USA) implants measuring 3.7mm in diameter x 10mm length were placed into respective osteotomies. A three-week period post-surgery was given to allow for healing to take place after which all three sheep were euthanized and the ilia were collected. Samples were prepared, qualitatively and quantitatively analyzed using histology micrographs and image analysis software (ImageJ, NIH, Bethesda, MD). Bone-to-implant contact (BIC) and bone area fraction occupancy (BAFO) were quantified to evaluate the osseointegration parameters. Results All implants exhibit successful bone formation in the peri-implant environment as well as within the open spaces of the trabecular network. Osseointegration within the TM (quantified by %BIC) as a function of drilling technique was more pronounced in OD samples(p>0.05). The %BAFO however shows a significant difference (p=0.036) between the CCW and R samples. Greater bone volume and frequency of bone chips are observed in OD samples. Conclusions The utilization of OD as a design for improved fixation of hardware was supported by increased levels of stability, both primary and secondary. Histological data with OD provided notably different results from those of the regular drilling method. Key words:Osseodensification drilling, trabecular tantalum metal, osteotomies, implants, subtractive drilling.","PeriodicalId":18367,"journal":{"name":"Medicina Oral, Patología Oral y Cirugía Bucal","volume":"11 1","pages":"e764 - e769"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"14","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medicina Oral, Patología Oral y Cirugía Bucal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4317/medoral.23108","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 14

Abstract

Background Surgical fixation of implants into bone for the correction of bone deformities or defects is a traditional approach for skeletal stabilization. Important measures of efficacy of implants include implant stability and osseointegration—the direct interaction between living bone and an implant. Osseointegration depends on successful implant placement and subsequent bone remodeling. This study utilized osseodensification drilling (OD) in a low bone density model using trabecular metal (TM) implants. Material and Methods Three osteotomy sites, Regular, OD-CW (clockwise), and OD-CCW (counterclockwise), were prepared in each ilium of three female sheep. Drilling was performed at 1100rpm with saline irrigation. Trabecular metal (TM) (Zimmer®, Parsippany, NJ, USA) implants measuring 3.7mm in diameter x 10mm length were placed into respective osteotomies. A three-week period post-surgery was given to allow for healing to take place after which all three sheep were euthanized and the ilia were collected. Samples were prepared, qualitatively and quantitatively analyzed using histology micrographs and image analysis software (ImageJ, NIH, Bethesda, MD). Bone-to-implant contact (BIC) and bone area fraction occupancy (BAFO) were quantified to evaluate the osseointegration parameters. Results All implants exhibit successful bone formation in the peri-implant environment as well as within the open spaces of the trabecular network. Osseointegration within the TM (quantified by %BIC) as a function of drilling technique was more pronounced in OD samples(p>0.05). The %BAFO however shows a significant difference (p=0.036) between the CCW and R samples. Greater bone volume and frequency of bone chips are observed in OD samples. Conclusions The utilization of OD as a design for improved fixation of hardware was supported by increased levels of stability, both primary and secondary. Histological data with OD provided notably different results from those of the regular drilling method. Key words:Osseodensification drilling, trabecular tantalum metal, osteotomies, implants, subtractive drilling.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
骨密度钻孔制备的截骨术中骨小梁金属钽植入物周围的成骨参数
背景外科固定植入物以矫正骨畸形或骨缺损是骨稳定的传统方法。衡量种植体疗效的重要指标包括种植体稳定性和骨整合——活骨与种植体之间的直接相互作用。骨整合取决于成功的种植体植入和随后的骨重塑。本研究使用骨小梁金属(TM)种植体在低骨密度模型中进行骨密度钻孔(OD)。材料与方法在3只母羊的每只髂骨上分别取常规、OD-CW(顺时针方向)和OD-CCW(逆时针方向)3个截骨点。钻孔速度为1100rpm,盐水冲洗。骨小梁金属(TM) (Zimmer®,Parsippany, NJ, USA)种植体直径3.7mm × 10mm,分别置入截骨术中。手术后三周的时间允许愈合,之后对所有三只羊实施安乐死并收集髂骨。制备样品,利用组织显微照片和图像分析软件(ImageJ, NIH, Bethesda, MD)对样品进行定性和定量分析。量化骨与种植体接触(BIC)和骨面积分数占用(BAFO)来评估骨整合参数。结果所有种植体均能在种植体周围环境和骨小梁网络开放空间内成功成骨。骨内的骨整合(以%BIC量化)作为钻孔技术的函数在OD样品中更为明显(p>0.05)。然而,在CCW和R样品之间,BAFO %显示出显著差异(p=0.036)。在OD样品中观察到更大的骨体积和骨碎片频率。结论:利用外径固定作为一种改进内固定的设计,可以提高主要和次要的稳定性水平。与常规钻孔方法相比,外径的组织学数据提供了明显不同的结果。关键词:骨密度钻孔,小梁金属钽,截骨术,植入物,减法钻孔。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Actinic cheilitis: Proposal of a clinical index Validity and reliability of the Turkish version of the orthognathic quality of life questionnaire in patients with dentofacial deformity Endoscopic findings in periapical surgery. A cross-sectional study of 206 roots Ameloblastomas mimicking apical periodontitis: a case series Influence of root width and dentin wall thickness evaluated by endoscopy upon the outcome of periapical surgery. A cohort study
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1