Design of a liquid bridge heat switch system based on the liquid bridge control for electronics cooling

Su-Heon Jeong, W. Nakayama, Sung-Ki Nam, Sun-Kyu Lee
{"title":"Design of a liquid bridge heat switch system based on the liquid bridge control for electronics cooling","authors":"Su-Heon Jeong, W. Nakayama, Sung-Ki Nam, Sun-Kyu Lee","doi":"10.1109/ECTC.2012.6249106","DOIUrl":null,"url":null,"abstract":"Recently, liquid bridge heat switch has been suggested as effective thermal management solutions for the various thermal problems. The liquid bridge heat switch can control the thermal resistance and the temperature of desired position by regulating the liquid bridge between objective areas. The liquid bridge heat switch system is composed of hot plate as an upper plate, cold plate as a lower plate, and actuators. “On” state demand, the supplied liquid generates liquid bridge between two plates and conducts heat from hot plate to cold plate. The amount of conducting heat and thermal resistance are controlled by the diameter and height of generated liquid bridge. To be an “Off” state, the generated liquid bridge is retrieved and ruptured eventually. At that time, the heat switch system has maximum thermal resistance. This result decreased conduction of heat. In order to realize the desired switch operation, the precise liquid bridge control is required. In this research, the liquid bridge behavior was studied to design the heat switch system. The effects of channel geometry and clearance on the liquid bridge behavior were verified and the liquid bridge rupture conditions were found out. Based on the investigation, the liquid bridge heat switch system was designed for the high power LED cooling system. In a series of experiment, the stable liquid bridge operation was achieved by designed channel geometry. The results also showed that proposed heat switch system was able to decrease the LED junction temperature and regulate the thermal resistance between hot and cold plate.","PeriodicalId":6384,"journal":{"name":"2012 IEEE 62nd Electronic Components and Technology Conference","volume":"47 1","pages":"1951-1954"},"PeriodicalIF":0.0000,"publicationDate":"2012-07-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE 62nd Electronic Components and Technology Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECTC.2012.6249106","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Recently, liquid bridge heat switch has been suggested as effective thermal management solutions for the various thermal problems. The liquid bridge heat switch can control the thermal resistance and the temperature of desired position by regulating the liquid bridge between objective areas. The liquid bridge heat switch system is composed of hot plate as an upper plate, cold plate as a lower plate, and actuators. “On” state demand, the supplied liquid generates liquid bridge between two plates and conducts heat from hot plate to cold plate. The amount of conducting heat and thermal resistance are controlled by the diameter and height of generated liquid bridge. To be an “Off” state, the generated liquid bridge is retrieved and ruptured eventually. At that time, the heat switch system has maximum thermal resistance. This result decreased conduction of heat. In order to realize the desired switch operation, the precise liquid bridge control is required. In this research, the liquid bridge behavior was studied to design the heat switch system. The effects of channel geometry and clearance on the liquid bridge behavior were verified and the liquid bridge rupture conditions were found out. Based on the investigation, the liquid bridge heat switch system was designed for the high power LED cooling system. In a series of experiment, the stable liquid bridge operation was achieved by designed channel geometry. The results also showed that proposed heat switch system was able to decrease the LED junction temperature and regulate the thermal resistance between hot and cold plate.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于液桥控制的电子冷却液桥热开关系统的设计
近年来,液体桥式热交换器被认为是解决各种热问题的有效方法。液桥热开关通过调节目标区域之间的液桥来控制热阻和期望位置的温度。液桥式热开关系统由热板为上板,冷板为下板和执行器组成。“接通”状态要求,供给的液体在两板之间产生液桥,并将热量从热板传导到冷板。导热量和热阻由生成液桥的直径和高度控制。在“关闭”状态下,生成的液桥被回收并最终破裂。此时,热交换系统具有最大的热阻。这一结果减少了热传导。为了实现理想的开关操作,需要精确的液桥控制。在本研究中,通过研究液桥特性来设计热交换系统。验证了通道几何形状和间隙对液桥性能的影响,找出了液桥破裂的条件。在此基础上,设计了用于大功率LED散热系统的液桥式热开关系统。在一系列的实验中,通过设计通道的几何形状,实现了稳定的液桥运行。结果还表明,该热开关系统能够降低LED结温,调节冷热板之间的热阻。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Parasitic electrical and electromagnetic effects Heat management Passive electronic components Interconnection technology Reliability and maintainability
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1