MATLAB-based software for Size-Specific Dose Estimation (SSDE) in Computed Tomography Examinations

Daryoush Khoramian, Soroush Sistani
{"title":"MATLAB-based software for Size-Specific Dose Estimation (SSDE) in Computed Tomography Examinations","authors":"Daryoush Khoramian, Soroush Sistani","doi":"10.22037/JPS.V7I2.11728","DOIUrl":null,"url":null,"abstract":"Primary and widely in use Computed Tomography (CT) dose descriptor is a volumetric CT Dose Index (CTDIv) that is usually measured by a pencil ionization chamber with active length of 100mm and polymethyl methacrylate (PMMA) phantom. CTDIv depends on scan parameters such as mAs, kV, collimation, tube rotation time but is independent of patient’s size and shape. For the purpose of a good estimation of dose received by the patients, American Association of Physicists in Medicine (AAPM) published the conversion factors for both 16 and 32cm (head and body phantoms respectively); through this, users can extract conversion factors according to lateral (LAT) and/or anterior-posterior (AP) sizes and calculate real CTDIv. Since this procedure is time consuming, we designed MATLAB-based software to reduce such calculations. To design the software, GUI toolbar of MATLAB software was used. To test the software, scan parameters of two patients for head and pelvis scan were read from PACS and lateral (LAT) and anterior-posterior (AP) sizes were measured. Finally, SSDEs were calculated for two patients by the software. The software can be measured based on AP and/or LAT measures and/or in special cases (under the age of 18) through patients' age.","PeriodicalId":16663,"journal":{"name":"Journal of paramedical sciences","volume":"30 1","pages":"35-38"},"PeriodicalIF":0.0000,"publicationDate":"2016-03-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of paramedical sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22037/JPS.V7I2.11728","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Primary and widely in use Computed Tomography (CT) dose descriptor is a volumetric CT Dose Index (CTDIv) that is usually measured by a pencil ionization chamber with active length of 100mm and polymethyl methacrylate (PMMA) phantom. CTDIv depends on scan parameters such as mAs, kV, collimation, tube rotation time but is independent of patient’s size and shape. For the purpose of a good estimation of dose received by the patients, American Association of Physicists in Medicine (AAPM) published the conversion factors for both 16 and 32cm (head and body phantoms respectively); through this, users can extract conversion factors according to lateral (LAT) and/or anterior-posterior (AP) sizes and calculate real CTDIv. Since this procedure is time consuming, we designed MATLAB-based software to reduce such calculations. To design the software, GUI toolbar of MATLAB software was used. To test the software, scan parameters of two patients for head and pelvis scan were read from PACS and lateral (LAT) and anterior-posterior (AP) sizes were measured. Finally, SSDEs were calculated for two patients by the software. The software can be measured based on AP and/or LAT measures and/or in special cases (under the age of 18) through patients' age.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于matlab的计算机断层扫描中尺寸特异性剂量估计(SSDE)软件
主要和广泛使用的计算机断层扫描(CT)剂量描述符是体积CT剂量指数(CTDIv),通常由有效长度为100mm的铅笔电离室和聚甲基丙烯酸甲酯(PMMA)幻影测量。CTDIv取决于扫描参数,如mAs, kV,准直,管旋转时间,但与患者的大小和形状无关。为了更好地估计患者接受的剂量,美国医学物理学家协会(AAPM)公布了16和32厘米(分别为头部和身体幻影)的转换因子;通过这种方法,用户可以根据侧(LAT)和/或前后(AP)大小提取转换因子,并计算出真实的CTDIv。由于这个过程比较耗时,我们设计了基于matlab的软件来减少这样的计算。软件设计采用MATLAB软件的GUI工具栏。为了测试该软件,我们从PACS中读取了两名患者的头部和骨盆扫描参数,并测量了侧位(LAT)和前后位(AP)尺寸。最后通过软件计算两例患者的SSDEs。该软件可以根据AP和/或LAT测量和/或在特殊情况下(18岁以下)通过患者年龄进行测量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The Putative Role of Factor V Leiden and Prothrombin Mutations in Pregnancy Complications Information Governance Program: A Review of Applications in Healthcare Strain Selection and Statistical Optimization of Culture Conditions for 19F Polysaccharide Production from Pneumococcus Influence of Moderate and Severe Exercise on Memory Formation and Anxiety-like Behaviors in Male Wistar Rat Anxiety Effect: A Case of Text Modification and the Effect of High and Low Anxiety Levels on Medical Students’ Comprehension Performance
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1