Omar Yusef Kudsi, Georges Kaoukabani, Naseem Bou-Ayash, Kelly Vallar, Alexandra Chudner, Sara LaGrange, Fahri Gokcal
{"title":"Quality of life and surgical outcomes of robotic retromuscular ventral hernia repair using a new hybrid mesh reinforcement.","authors":"Omar Yusef Kudsi, Georges Kaoukabani, Naseem Bou-Ayash, Kelly Vallar, Alexandra Chudner, Sara LaGrange, Fahri Gokcal","doi":"10.1007/s10029-022-02619-5","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The purpose of this study is to prospectively evaluate surgical and quality of life (QoL) outcomes of robotic retromuscular ventral hernia repair (rRMVHR) using a new hybrid mesh in high-risk patients.</p><p><strong>Methods: </strong>Data was prospectively collected for patients classified as high-risk based on the modified ventral hernia working group (VHWG) grading system, who underwent rRMVHR using Synecor™ Pre hybrid mesh in a single center, between 2019 and 2020. Pre-, intra- and postoperative variables including hernia recurrence, surgical site events (SSE), hernia-specific quality of life (QoL), and financial costs were analyzed. QoL assessments were obtained from preoperative and postoperative patient visits. Kaplan-Meier survival analysis was performed to analyze the estimated recurrence-free time.</p><p><strong>Results: </strong>Fifty-two high-risk patients, with a mean (±SD) age of 58.6 ± 13.7 years and BMI of 36.9 ± 6.6 kg/m<sup>2</sup>, were followed for a mean (±SD) period of 22.4 ± 7.1 months. A total of 11 (21.2%) patients experienced postoperative complications, out of which eight were SSEs, including 7 (13.5%) seromas, 1 (1.9%) hematoma, and no infections. Procedural interventions were required for 2 (3.8%) surgical site occurrences. Recurrence was seen in 1 (1.9%) patient. The estimated mean (95% confidence interval) recurrence-free time was 33 (32.3-34.5) months. Postoperative QoL assessments demonstrated significant improvements in comparison to preoperative QoL, with a minimum ∆mean (±SD) of -15.5 ± 2.2 at one month (p < 0.001). The mean (±SD) procedure cost was $13,924.18 ± 7856.95 which includes the average mesh cost ($5390.12 ± 3817.03).</p><p><strong>Conclusion: </strong>Our study showed favorable early and mid-term outcomes, in addition to significant improvements in QoL, after rRMVHR using Synecor™ hybrid mesh in high-risk patients.</p>","PeriodicalId":8032,"journal":{"name":"Annals of Statistics","volume":"20 1","pages":"881-888"},"PeriodicalIF":3.2000,"publicationDate":"2022-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Statistics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10029-022-02619-5","RegionNum":1,"RegionCategory":"数学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/4/28 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"STATISTICS & PROBABILITY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: The purpose of this study is to prospectively evaluate surgical and quality of life (QoL) outcomes of robotic retromuscular ventral hernia repair (rRMVHR) using a new hybrid mesh in high-risk patients.
Methods: Data was prospectively collected for patients classified as high-risk based on the modified ventral hernia working group (VHWG) grading system, who underwent rRMVHR using Synecor™ Pre hybrid mesh in a single center, between 2019 and 2020. Pre-, intra- and postoperative variables including hernia recurrence, surgical site events (SSE), hernia-specific quality of life (QoL), and financial costs were analyzed. QoL assessments were obtained from preoperative and postoperative patient visits. Kaplan-Meier survival analysis was performed to analyze the estimated recurrence-free time.
Results: Fifty-two high-risk patients, with a mean (±SD) age of 58.6 ± 13.7 years and BMI of 36.9 ± 6.6 kg/m2, were followed for a mean (±SD) period of 22.4 ± 7.1 months. A total of 11 (21.2%) patients experienced postoperative complications, out of which eight were SSEs, including 7 (13.5%) seromas, 1 (1.9%) hematoma, and no infections. Procedural interventions were required for 2 (3.8%) surgical site occurrences. Recurrence was seen in 1 (1.9%) patient. The estimated mean (95% confidence interval) recurrence-free time was 33 (32.3-34.5) months. Postoperative QoL assessments demonstrated significant improvements in comparison to preoperative QoL, with a minimum ∆mean (±SD) of -15.5 ± 2.2 at one month (p < 0.001). The mean (±SD) procedure cost was $13,924.18 ± 7856.95 which includes the average mesh cost ($5390.12 ± 3817.03).
Conclusion: Our study showed favorable early and mid-term outcomes, in addition to significant improvements in QoL, after rRMVHR using Synecor™ hybrid mesh in high-risk patients.
期刊介绍:
The Annals of Statistics aim to publish research papers of highest quality reflecting the many facets of contemporary statistics. Primary emphasis is placed on importance and originality, not on formalism. The journal aims to cover all areas of statistics, especially mathematical statistics and applied & interdisciplinary statistics. Of course many of the best papers will touch on more than one of these general areas, because the discipline of statistics has deep roots in mathematics, and in substantive scientific fields.