Tap Water Purification Using Pitcher Filters

IF 0.5 Q4 ENGINEERING, CIVIL Architecture Civil Engineering Environment Pub Date : 2022-12-01 DOI:10.2478/acee-2022-0046
E. Puszczało, G. Kamińska, A. Marszałek
{"title":"Tap Water Purification Using Pitcher Filters","authors":"E. Puszczało, G. Kamińska, A. Marszałek","doi":"10.2478/acee-2022-0046","DOIUrl":null,"url":null,"abstract":"Abstract Due to the high risk of exposure to various contaminants in drinking water, pitcher filtration is rapidly growing in popularity worldwide as a cheap and easy method to remove pollutants from drinking water. On the other hand, an evaluation of the real-time performance of pitchers is not possible for usual consumers. This study presents the performance of pitcher filtration in the removal of copper, chlorine, and chloroform from tap drinking water. Pitchers were packed with Aquaphor cartridges JS500, A5, and B25. Experiments were performed with model solutions, which were prepared from hard drinking water (7.5 mval/L, pH=7) spiked with copper, hypochlorite sodium, and chloroform. It was found that pitcher filtration is a very effective method for the removal of pollutants such as heavy metals, chlorine, and disinfectants byproducts. The concentration of copper, chlorine, and chloroform in filtrates did not exceed the maximum admissible values. Cartridges JS500, A5, and B25 reduced chlorine at a comparable level – almost 100%. During the whole experimental period, removal of chloroform was slightly better for JS500 (100%) and A5 (100%) cartridges than for B25 (91.4–97.7%).","PeriodicalId":8117,"journal":{"name":"Architecture Civil Engineering Environment","volume":"19 1","pages":"159 - 166"},"PeriodicalIF":0.5000,"publicationDate":"2022-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Architecture Civil Engineering Environment","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/acee-2022-0046","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract Due to the high risk of exposure to various contaminants in drinking water, pitcher filtration is rapidly growing in popularity worldwide as a cheap and easy method to remove pollutants from drinking water. On the other hand, an evaluation of the real-time performance of pitchers is not possible for usual consumers. This study presents the performance of pitcher filtration in the removal of copper, chlorine, and chloroform from tap drinking water. Pitchers were packed with Aquaphor cartridges JS500, A5, and B25. Experiments were performed with model solutions, which were prepared from hard drinking water (7.5 mval/L, pH=7) spiked with copper, hypochlorite sodium, and chloroform. It was found that pitcher filtration is a very effective method for the removal of pollutants such as heavy metals, chlorine, and disinfectants byproducts. The concentration of copper, chlorine, and chloroform in filtrates did not exceed the maximum admissible values. Cartridges JS500, A5, and B25 reduced chlorine at a comparable level – almost 100%. During the whole experimental period, removal of chloroform was slightly better for JS500 (100%) and A5 (100%) cartridges than for B25 (91.4–97.7%).
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
自来水净化使用水罐过滤器
摘要由于饮用水中暴露于各种污染物的风险很高,猪笼过滤作为一种廉价、简便的去除饮用水中污染物的方法在世界范围内迅速普及。另一方面,对于普通消费者来说,对投手的实时表现进行评估是不可能的。本研究介绍了猪笼过滤去除自来水中铜、氯和氯仿的性能。罐子里装着阿夸弗JS500、A5和B25墨盒。实验用模型溶液进行,模型溶液由硬饮用水(7.5 mval/L, pH=7)加入铜、次氯酸钠和氯仿制备。结果表明,猪笼过滤是一种非常有效的去除重金属、氯和消毒剂副产物等污染物的方法。滤液中铜、氯和氯仿的浓度未超过最大允许值。墨盒JS500、A5和B25在相当水平上减少了氯——几乎100%。在整个试验期内,JS500(100%)和A5(100%)对氯仿的去除率略好于B25(91.4% ~ 97.7%)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
20.00%
发文量
0
期刊最新文献
Heating Ceiling System Efficiency in Different Climate Zones Experimental Tests of Laminated Glass with Embedded Steel Mesh Subjected to In-Plane Loading Professional Profile Map as a Powerful Educational Tool for Architects and Civil Engineers How do High-Rise Buildings Affect the Mental Image of Users? Case Study: Seljuk Tower in Konya Spatial Analysis of the Impact of Motor Vehicle Fires on the Urban Environment using the Example of Warsaw
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1