Determination of Some Trace Heavy Metals in Some Water Samples by FAAS After Their Preconcentration Using DETA

Yasemin Bakircioglu, S. Akman, N. Bıçak, F. Şenkal
{"title":"Determination of Some Trace Heavy Metals in Some Water Samples by FAAS After Their Preconcentration Using DETA","authors":"Yasemin Bakircioglu, S. Akman, N. Bıçak, F. Şenkal","doi":"10.1081/TMA-120020259","DOIUrl":null,"url":null,"abstract":"Abstract Diethylenetriamine, DETA polymer was used as a preconcentration of cobalt, iron and nickel prior to their determination by flame atomic absorption spectrometry (FAAS). Both batch and column methods were used for the separation and concentration of above metals. These metals were quantitatively retained on the proposed adsorbent at pH 2, then were quantitatively eluted with 2 M hydrochloric acid or nitric acid. The recoveries of metal ions were greater than 98%. Detection limits (3 δ) were 1.5 µg/L for Co, 2.1 µg/L for Fe and 1.9 µg/L for Ni. The relative standard deviations for the determinations were found to be 1.0–8.8%. The effect of Na on the preconcentration of trace metals has also been investigated. The method was applied to tap, ground and lake water samples.","PeriodicalId":17525,"journal":{"name":"Journal of Trace and Microprobe Techniques","volume":"6 1","pages":"239 - 248"},"PeriodicalIF":0.0000,"publicationDate":"2003-01-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Trace and Microprobe Techniques","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1081/TMA-120020259","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

Abstract

Abstract Diethylenetriamine, DETA polymer was used as a preconcentration of cobalt, iron and nickel prior to their determination by flame atomic absorption spectrometry (FAAS). Both batch and column methods were used for the separation and concentration of above metals. These metals were quantitatively retained on the proposed adsorbent at pH 2, then were quantitatively eluted with 2 M hydrochloric acid or nitric acid. The recoveries of metal ions were greater than 98%. Detection limits (3 δ) were 1.5 µg/L for Co, 2.1 µg/L for Fe and 1.9 µg/L for Ni. The relative standard deviations for the determinations were found to be 1.0–8.8%. The effect of Na on the preconcentration of trace metals has also been investigated. The method was applied to tap, ground and lake water samples.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
原子吸收光谱法测定部分水样中痕量重金属
摘要采用火焰原子吸收光谱法(FAAS)测定钴、铁和镍的含量,采用二乙烯三胺(DETA)聚合物作为预富集剂。采用批法和柱法对上述金属进行分离和富集。这些金属在pH为2时被定量地保留在所建议的吸附剂上,然后用2m的盐酸或硝酸定量地洗脱。金属离子的回收率大于98%。Co的检出限(3 δ)为1.5µg/L, Fe为2.1µg/L, Ni为1.9µg/L。测定结果的相对标准偏差为1.0 ~ 8.8%。研究了Na对微量金属富集的影响。该方法应用于自来水、地表水和湖泊水样。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Portable systems for energy dispersive X-ray fluorescence analysis of works of art Provenance Study of Archaeological Ceramic Bioanalysis of Bilirubin: State of Our Art and Future Developments (Review Article) Molecular Charge Transfer Complexes of Norfloxacin with Nitrobenzenes Elemental Composition of the Vegetation on the Island Krk
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1