{"title":"Exposure to Hydrazine and its Control in Power Plants","authors":"T. Kauppinen, J. Alho, L. Lindroos","doi":"10.1080/08828032.1989.10388585","DOIUrl":null,"url":null,"abstract":"Abstract The use of hydrazine in power plants was surveyed with a postal inquiry to detect differences in exposure when alternative technical procedures were used in the handling of hydrazine. The exposure level of employees in eight plants was estimated based on the concentration of hydrazine in the air and the potential absorption through the skin. The questionnaire was sent to 288 power plants and 264 were returned, 100 of which used hydrazine. About 500 employees dosed and diluted strong (15% or 35%) hydrazine solution. The dosing was usually done with a pump or an ejector in bigger plants and with a measure in small plants. The airborne hydrazine concentrations in the rooms where hydrazine was handled were: < 0.01–0.06 ppm (mean < 0.02 ppm) for dosing with measure; < 0.01–0.37 ppm (mean 0.12 ppm) for dosing with pump; < 0.01–0.33 ppm (mean 0.09 ppm) for dosing with ejector, tank not closed; and < 0.01–0.04 ppm (mean 0.02 ppm) for dosing with ejector, tank closed and equipped with exhaust. The time-we...","PeriodicalId":8049,"journal":{"name":"Applied Industrial Hygiene","volume":"87 1","pages":"245-250"},"PeriodicalIF":0.0000,"publicationDate":"1989-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Industrial Hygiene","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/08828032.1989.10388585","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Abstract The use of hydrazine in power plants was surveyed with a postal inquiry to detect differences in exposure when alternative technical procedures were used in the handling of hydrazine. The exposure level of employees in eight plants was estimated based on the concentration of hydrazine in the air and the potential absorption through the skin. The questionnaire was sent to 288 power plants and 264 were returned, 100 of which used hydrazine. About 500 employees dosed and diluted strong (15% or 35%) hydrazine solution. The dosing was usually done with a pump or an ejector in bigger plants and with a measure in small plants. The airborne hydrazine concentrations in the rooms where hydrazine was handled were: < 0.01–0.06 ppm (mean < 0.02 ppm) for dosing with measure; < 0.01–0.37 ppm (mean 0.12 ppm) for dosing with pump; < 0.01–0.33 ppm (mean 0.09 ppm) for dosing with ejector, tank not closed; and < 0.01–0.04 ppm (mean 0.02 ppm) for dosing with ejector, tank closed and equipped with exhaust. The time-we...