{"title":"High Dynamic Range Sensing Using Multi-Channel Modulo Samplers","authors":"Lu Gan, Hongqing Liu","doi":"10.1109/SAM48682.2020.9104340","DOIUrl":null,"url":null,"abstract":"We consider the problem of recovering a band-limited signal from multi-channel modulo folded measurements. The study is motivated by the recent advances of self-reset analog-to-digital converters (SR-ADCs) for high dynamic range digitization. Most of existing works focus on single-channel SR-ADC, which requires high sampling rate and the reconstruction could be very unstable at low signal to noise ratio. To our best knowledge, this is the first work that studies multi-channel SR-ADC systems. In the noiseless case, we show that perfect reconstruction can be achieved using only 2 channels, each of which samples at Nyquist rate. For noisy measurements, we develop a lattice-based optimization for stable reconstruction. Simulation results are presented to demonstrate the effectiveness of the proposed algorithms.","PeriodicalId":6753,"journal":{"name":"2020 IEEE 11th Sensor Array and Multichannel Signal Processing Workshop (SAM)","volume":"36 1","pages":"1-5"},"PeriodicalIF":0.0000,"publicationDate":"2020-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE 11th Sensor Array and Multichannel Signal Processing Workshop (SAM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SAM48682.2020.9104340","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11
Abstract
We consider the problem of recovering a band-limited signal from multi-channel modulo folded measurements. The study is motivated by the recent advances of self-reset analog-to-digital converters (SR-ADCs) for high dynamic range digitization. Most of existing works focus on single-channel SR-ADC, which requires high sampling rate and the reconstruction could be very unstable at low signal to noise ratio. To our best knowledge, this is the first work that studies multi-channel SR-ADC systems. In the noiseless case, we show that perfect reconstruction can be achieved using only 2 channels, each of which samples at Nyquist rate. For noisy measurements, we develop a lattice-based optimization for stable reconstruction. Simulation results are presented to demonstrate the effectiveness of the proposed algorithms.