Corrosion of steel in a CO2-containing solution droplet generated in wet gas pipelines studied by scanning Kelvin probe

IF 4.8 Q2 ENERGY & FUELS Journal of Pipeline Science and Engineering Pub Date : 2022-03-01 DOI:10.1016/j.jpse.2021.12.003
Shan Qian, Y. Frank Cheng
{"title":"Corrosion of steel in a CO2-containing solution droplet generated in wet gas pipelines studied by scanning Kelvin probe","authors":"Shan Qian,&nbsp;Y. Frank Cheng","doi":"10.1016/j.jpse.2021.12.003","DOIUrl":null,"url":null,"abstract":"<div><p>A scanning Kelvin probe (SKP) was used to study corrosion of X52 pipeline steel under a CO<sub>2</sub>-containing solution droplet simulating the water condensate generated in interior of wet gas pipelines. The Volta potential measured by SKP was indicative of the feature of corrosion occurring under the droplet. Three potential zones were observed from the droplet center towards the transition and the side of the droplet, which were -0.1 V, -0.4 V and 0.1 V (Kelvin probe, kp), respectively, after 4 h of testing. The droplet side had the highest Volta potential, which was attributed to corrosion scale generation and precipitation due to a limited solution volume and achieved solubility limit of FeCO<sub>3</sub> scale. The transition zone possessed the most negative Volta potential due to a higher corrosion activity than the droplet center with more supply and dissolution of CO<sub>2</sub>, while the droplet center had the thickest solution. The SKP measurements could estimate the volume evolution of the solution droplet with time at a relatively accurate scale. The solution droplet could maintain its topographic feature, i.e., a spherical cap shape, within 4 h of testing in this work. The increase in droplet concentration due to solution evaporation during testing affected the Volta potential, but slightly only.</p></div>","PeriodicalId":100824,"journal":{"name":"Journal of Pipeline Science and Engineering","volume":"2 1","pages":"Pages 71-77"},"PeriodicalIF":4.8000,"publicationDate":"2022-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2667143321000780/pdfft?md5=7b71ebd0dfb24d096cc62af892e276f3&pid=1-s2.0-S2667143321000780-main.pdf","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Pipeline Science and Engineering","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2667143321000780","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 6

Abstract

A scanning Kelvin probe (SKP) was used to study corrosion of X52 pipeline steel under a CO2-containing solution droplet simulating the water condensate generated in interior of wet gas pipelines. The Volta potential measured by SKP was indicative of the feature of corrosion occurring under the droplet. Three potential zones were observed from the droplet center towards the transition and the side of the droplet, which were -0.1 V, -0.4 V and 0.1 V (Kelvin probe, kp), respectively, after 4 h of testing. The droplet side had the highest Volta potential, which was attributed to corrosion scale generation and precipitation due to a limited solution volume and achieved solubility limit of FeCO3 scale. The transition zone possessed the most negative Volta potential due to a higher corrosion activity than the droplet center with more supply and dissolution of CO2, while the droplet center had the thickest solution. The SKP measurements could estimate the volume evolution of the solution droplet with time at a relatively accurate scale. The solution droplet could maintain its topographic feature, i.e., a spherical cap shape, within 4 h of testing in this work. The increase in droplet concentration due to solution evaporation during testing affected the Volta potential, but slightly only.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用扫描开尔文探针研究了湿气管道中含二氧化碳溶液液滴对钢的腐蚀
采用扫描开尔文探针(SKP)研究了模拟湿气管道内部冷凝水的含co2溶液滴对X52管线钢的腐蚀。SKP测量的伏特电位反映了液滴下发生腐蚀的特征。测试4 h后,从液滴中心向过渡区和液滴侧面观察到三个电位区,分别为-0.1 V、-0.4 V和0.1 V(开尔文探针,kp)。液滴侧的Volta电位最高,这是由于溶液体积有限导致腐蚀结垢生成和沉淀,达到了FeCO3结垢的溶解度极限。由于过渡区比液滴中心具有更高的腐蚀活性和更多的CO2供应和溶解,因此具有最大的负伏特电位,而液滴中心具有最厚的溶液。SKP测量可以在相对精确的尺度上估计溶液液滴随时间的体积演变。在本工作测试的4小时内,溶液液滴可以保持其形貌特征,即球形帽状。测试过程中由于溶液蒸发引起的液滴浓度的增加对伏特电位有影响,但影响很小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
7.50
自引率
0.00%
发文量
0
期刊最新文献
Editorial board Study on scour stripping of oil-wax gels in pipes Development of a sectionalizing method for simulation of large-scale complicated natural gas pipeline networks Corrosion protection characteristics of doped magnetite layers on carbon steel surfaces in aqueous CO2 environments Editorial board
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1