Field determination of trace molybdenum in river‐water samples by a visual catalytic method

S. Kawakubo, K. Ogihara, Masanobu Watanabe, M. Iwatsuki
{"title":"Field determination of trace molybdenum in river‐water samples by a visual catalytic method","authors":"S. Kawakubo, K. Ogihara, Masanobu Watanabe, M. Iwatsuki","doi":"10.1002/(SICI)1520-6521(1999)3:1<29::AID-FACT4>3.0.CO;2-#","DOIUrl":null,"url":null,"abstract":"A sensitive visual colorimetric method has been developed for the semiquantitative field determination of trace molybdenum. The molybdenum-catalyzed oxidation of ascorbic acid at pH 3.2 in the presence of o-phenylenediamine was used as the indicator reaction, which produces yellow quinoxaline derivatives. After a fixed reaction time, the reaction is stopped by readjusting pH to 1 with hydrochloric acid. For the visual determination, the color intensity of the final solution (10 ml) for a water sample is compared to that of a color standard solution containing 0.04 μg (4 μg l−1) of MoVI prepared by the same procedure. Two handmade cells of the same size with 10-, 20-, 30- and 40-mm light paths are used in the color comparison for a wide determination range (0.005–0.2 μg). The intensity of the color standard is held constant by the adjustment of the reaction time, for example, 10 min at 25 °C, with the use of a simple relationship between the reaction time and the field temperature. Molybdenum down to 1 μg l−1 in a 4-ml river-water sample was determined without any special instrument. Analytical performances were evaluated and compared with those obtained by the spectrophotometric measurements. The application to field survey has revealed the distribution of molybdenum concentration along the river streams and a polluted point. ©1999 John Wiley & Sons, Inc. Field Analyt Chem Technol 3:29–35, 1999","PeriodicalId":12132,"journal":{"name":"Field Analytical Chemistry and Technology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1999-02-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Field Analytical Chemistry and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/(SICI)1520-6521(1999)3:1<29::AID-FACT4>3.0.CO;2-#","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

A sensitive visual colorimetric method has been developed for the semiquantitative field determination of trace molybdenum. The molybdenum-catalyzed oxidation of ascorbic acid at pH 3.2 in the presence of o-phenylenediamine was used as the indicator reaction, which produces yellow quinoxaline derivatives. After a fixed reaction time, the reaction is stopped by readjusting pH to 1 with hydrochloric acid. For the visual determination, the color intensity of the final solution (10 ml) for a water sample is compared to that of a color standard solution containing 0.04 μg (4 μg l−1) of MoVI prepared by the same procedure. Two handmade cells of the same size with 10-, 20-, 30- and 40-mm light paths are used in the color comparison for a wide determination range (0.005–0.2 μg). The intensity of the color standard is held constant by the adjustment of the reaction time, for example, 10 min at 25 °C, with the use of a simple relationship between the reaction time and the field temperature. Molybdenum down to 1 μg l−1 in a 4-ml river-water sample was determined without any special instrument. Analytical performances were evaluated and compared with those obtained by the spectrophotometric measurements. The application to field survey has revealed the distribution of molybdenum concentration along the river streams and a polluted point. ©1999 John Wiley & Sons, Inc. Field Analyt Chem Technol 3:29–35, 1999
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
目视催化法现场测定河水样品中痕量钼
建立了一种灵敏的视觉比色法半定量测定痕量钼。以pH为3.2、邻苯二胺存在下钼催化抗坏血酸氧化为指示剂,制得黄色喹诺啉衍生物。在固定的反应时间后,用盐酸将pH调整为1停止反应。为了目测,将水样最终溶液(10ml)的颜色强度与用相同方法制备的含有0.04 μg (4 μg l−1)MoVI的颜色标准溶液的颜色强度进行比较。颜色比较采用两个相同尺寸的手工细胞,光路分别为10、20、30和40毫米,测定范围宽(0.005-0.2 μg)。通过调整反应时间来保持色标的强度恒定,例如,在25°C下10分钟,使用反应时间和现场温度之间的简单关系。在没有任何特殊仪器的情况下,测定了4毫升河水样品中低至1 μg l−1的钼。评价了分析性能,并与分光光度法测定结果进行了比较。通过野外调查,揭示了河流及污染点钼的分布规律。©1999 John Wiley & Sons, Inc现场分析化学技术,1999 (3):29 - 35
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Development and evaluation of a low thermal mass gas chromatograph for rapid forensic GC–MS analyses Field detection and identification of a bioaerosol suite by pyrolysis-gas chromatography-ion mobility spectrometry* Multivariate data analysis of fluorescence signals from biological aerosols Biological agent detection and identification by the Block II Chemical Biological Mass Spectrometer Rapid determination of bacteria in drinking water using an ATP assay
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1