Evaluating Reproducibility of the ADC and Distortion in Diffusion-weighted Imaging (DWI) with Reverse Encoding Distortion Correction (RDC).

Hitomi Numamoto, Koji Fujimoto, Kanae Kawai Miyake, Yasutaka Fushimi, Sachi Okuchi, Rimika Imai, Hiroki Kondo, Tsuneo Saga, Yuji Nakamoto
{"title":"Evaluating Reproducibility of the ADC and Distortion in Diffusion-weighted Imaging (DWI) with Reverse Encoding Distortion Correction (RDC).","authors":"Hitomi Numamoto, Koji Fujimoto, Kanae Kawai Miyake, Yasutaka Fushimi, Sachi Okuchi, Rimika Imai, Hiroki Kondo, Tsuneo Saga, Yuji Nakamoto","doi":"10.2463/mrms.mp.2023-0102","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To compare image distortion and reproducibility of quantitative values between reverse encoding distortion correction (RDC) diffusion-weighted imaging (DWI) and conventional DWI techniques in a phantom study and in healthy volunteers.</p><p><strong>Methods: </strong>This prospective study was conducted with the approval of our institutional review board. Written informed consent was obtained from each participant. RDC-DWIs were created from images obtained at 3T in three orthogonal directions in a phantom and in 10 participants (mean age, 70.9 years; age range, 63-83 years). Images without distortion correction (noDC-DWI) and those corrected with B0 (B0c-DWI) were also created. To evaluate distortion, coefficients of variation were calculated for each voxel and ROIs were placed at four levels of the brain. To evaluate the reproducibility of apparent diffusion coefficient (ADC) measurements, intra- and inter-scan variability (%CV<sub>ADC</sub>) were calculated from repeated scans of the phantom. Analysis was performed using Wilcoxon signed-rank test with Bonferroni correction, and P < 0.05 was considered statistically significant.</p><p><strong>Results: </strong>In the phantom, distortion was less in RDC-DWI than in B0c-DWI (P < 0.006), and was less in B0c-DWI than in noDC-DWI (P < 0.006). Intra-scan %CV<sub>ADC</sub> was within 1.30%, and inter-scan %CV<sub>ADC</sub> was within 2.99%. In the volunteers, distortion was less in RDC-DWI than in B0c-DWI in three of four locations (P < 0.006), and was less in B0c-DWI than in noDC-DWI (P < 0.006). At the middle cerebellar peduncle, distortion was less in RDC-DWI than in noDC-DWI (P < 0.006), and was less in noDC-DWI than in B0c-DWI (P < 0.0177).</p><p><strong>Conclusion: </strong>In both the phantom and in volunteers, distortion was the least in RDC-DWI than in B0c-DWI and noDC-DWI.</p>","PeriodicalId":94126,"journal":{"name":"Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine","volume":" ","pages":"66-77"},"PeriodicalIF":0.0000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11733504/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2463/mrms.mp.2023-0102","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/11/10 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To compare image distortion and reproducibility of quantitative values between reverse encoding distortion correction (RDC) diffusion-weighted imaging (DWI) and conventional DWI techniques in a phantom study and in healthy volunteers.

Methods: This prospective study was conducted with the approval of our institutional review board. Written informed consent was obtained from each participant. RDC-DWIs were created from images obtained at 3T in three orthogonal directions in a phantom and in 10 participants (mean age, 70.9 years; age range, 63-83 years). Images without distortion correction (noDC-DWI) and those corrected with B0 (B0c-DWI) were also created. To evaluate distortion, coefficients of variation were calculated for each voxel and ROIs were placed at four levels of the brain. To evaluate the reproducibility of apparent diffusion coefficient (ADC) measurements, intra- and inter-scan variability (%CVADC) were calculated from repeated scans of the phantom. Analysis was performed using Wilcoxon signed-rank test with Bonferroni correction, and P < 0.05 was considered statistically significant.

Results: In the phantom, distortion was less in RDC-DWI than in B0c-DWI (P < 0.006), and was less in B0c-DWI than in noDC-DWI (P < 0.006). Intra-scan %CVADC was within 1.30%, and inter-scan %CVADC was within 2.99%. In the volunteers, distortion was less in RDC-DWI than in B0c-DWI in three of four locations (P < 0.006), and was less in B0c-DWI than in noDC-DWI (P < 0.006). At the middle cerebellar peduncle, distortion was less in RDC-DWI than in noDC-DWI (P < 0.006), and was less in noDC-DWI than in B0c-DWI (P < 0.0177).

Conclusion: In both the phantom and in volunteers, distortion was the least in RDC-DWI than in B0c-DWI and noDC-DWI.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用反向编码失真校正(RDC)评估扩散加权成像(DWI)中ADC的再现性和失真。
目的:比较反向编码失真校正(RDC)扩散加权成像(DWI)与常规DWI技术在假体研究和健康志愿者中的图像畸变和定量值的可重复性。方法:本前瞻性研究是经我们机构审查委员会批准进行的。每位参与者都获得了书面知情同意书。rdc - dwi是根据在3个正交方向上在3T时获得的幻象和10名参与者的图像创建的(平均年龄70.9岁;年龄范围:63-83岁。同时生成未进行畸变校正的图像(noDC-DWI)和经过B0校正的图像(B0c-DWI)。为了评估失真,计算每个体素的变异系数,并将roi放置在大脑的四个层次上。为了评估表观扩散系数(ADC)测量的可重复性,通过重复扫描幻影计算扫描内和扫描间变异性(%CVADC)。采用Wilcoxon符号秩检验,Bonferroni校正,以P < 0.05为差异有统计学意义。结果:在幻体中,RDC-DWI比B0c-DWI畸变少(P < 0.006), B0c-DWI比noDC-DWI畸变少(P < 0.006)。扫描内%CVADC在1.30%以内,扫描间%CVADC在2.99%以内。在志愿者中,四个位置中有三个位置RDC-DWI的畸变小于b0 - dwi (P < 0.006), b0 - dwi的畸变小于noc - dwi (P < 0.006)。在小脑中端,RDC-DWI的扭曲程度低于noDC-DWI (P < 0.006), noDC-DWI的扭曲程度低于B0c-DWI (P < 0.0177)。结论:RDC-DWI在幻体和志愿者中畸变程度均小于B0c-DWI和noDC-DWI。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Breast Diffusion-weighted MR Imaging: Current Applications, Insights from Screening, and Future Directions. Institutional Variability in Ultrafast Breast MR Imaging: Comparing Compressed Sensing and View Sharing Techniques with Different Patient Populations and Contrast Injection Protocols. MR Imaging Indices for Brain Interstitial Fluid Dynamics and the Effects of Orexin Antagonists on Sleep. Toward Clinical Implementation of Magnetic Resonance Imaging for Placental Function. Computational Design of a Thermal Applicator for Brain Hyperthermia Controlled by Capacitor Positioning in Loop Coils.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1