A comparison of transient elastography with acoustic radiation force impulse elastography for the assessment of liver health in patients with chronic hepatitis C: Baseline results from the TRACER study.

IF 2 3区 农林科学 Q2 AGRONOMY Agronomy Journal Pub Date : 2023-11-01 Epub Date: 2023-01-04 DOI:10.1177/1742271X221139181
Therese Herlihy, Mary Moran, Aoife Heeney, Hajra Okhai, Davide De Franceso, Carmel Cronin, Eoin Feeney, Diarmuid Houlihan, Stephen Stewart, Aoife G Cotter
{"title":"A comparison of transient elastography with acoustic radiation force impulse elastography for the assessment of liver health in patients with chronic hepatitis C: Baseline results from the TRACER study.","authors":"Therese Herlihy, Mary Moran, Aoife Heeney, Hajra Okhai, Davide De Franceso, Carmel Cronin, Eoin Feeney, Diarmuid Houlihan, Stephen Stewart, Aoife G Cotter","doi":"10.1177/1742271X221139181","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Liver stiffness measurements can be used to assess liver fibrosis and can be acquired by transient elastography using FibroScan<sup>®</sup> and with Acoustic Radiation Force Impulse imaging. The study aimed to establish liver stiffness measurement scores using FibroScan<sup>®</sup> and Acoustic Radiation Force Impulse in a chronic hepatitis C cohort and to explore the correlation and agreement between the scores and the factors influencing agreement.</p><p><strong>Methods: </strong>Patients had liver stiffness measurements acquired with FibroScan® (right lobe of liver) and Acoustic Radiation Force Impulse (right and left lobe of liver). We used Spearman's correlation to explore the relationship between FibroScan® and Acoustic Radiation Force Impulse scores. A Bland-Altman plot was used to evaluate bias between the mean percentage differences of FibroScan® and Acoustic Radiation Force Impulse scores. Univariable and multivariable analyses were used to assess how factors such as body mass index, age and gender influenced the agreement between liver stiffness measurements.</p><p><strong>Results: </strong>Bland-Altman showed the average (95% CI) percentage difference between FibroScan® and Acoustic Radiation Force Impulse scores was 27.5% (17.8, 37.2), <i>p</i>  < 0.001. There was a negative correlation between the average and percentage difference of the FibroScan<sup>®</sup> and Acoustic Radiation Force Impulse scores ( <i>r</i> (95% CI) = -0.41 (-0.57, -0.21), <i>p</i> < 0.001), thus showing that percentage difference gets smaller for greater FibroScan<sup>®</sup> and Acoustic Radiation Force Impulse scores. Body mass index was the biggest influencing factor on differences between FibroScan<sup>®</sup> and Acoustic Radiation Force Impulse (<i>r</i> = 0.12 (0.01, 0.23), <i>p</i> = 0.05). Acoustic Radiation Force Impulse scores at segment 5/8 and the left lobe showed good correlation (<i>r</i> (95% CI) = 0.83 (0.75, 0.89), <i>p</i> < 0.001).</p><p><strong>Conclusion: </strong>FibroScan<sup>®</sup> and Acoustic Radiation Force Impulse had similar predictive values for the assessment of liver stiffness in patients with chronic hepatitis C infection; however, the level of agreement varied across lower and higher scores.</p>","PeriodicalId":7522,"journal":{"name":"Agronomy Journal","volume":"77 1","pages":"244-253"},"PeriodicalIF":2.0000,"publicationDate":"2023-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10621485/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Agronomy Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/1742271X221139181","RegionNum":3,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/1/4 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"AGRONOMY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Liver stiffness measurements can be used to assess liver fibrosis and can be acquired by transient elastography using FibroScan® and with Acoustic Radiation Force Impulse imaging. The study aimed to establish liver stiffness measurement scores using FibroScan® and Acoustic Radiation Force Impulse in a chronic hepatitis C cohort and to explore the correlation and agreement between the scores and the factors influencing agreement.

Methods: Patients had liver stiffness measurements acquired with FibroScan® (right lobe of liver) and Acoustic Radiation Force Impulse (right and left lobe of liver). We used Spearman's correlation to explore the relationship between FibroScan® and Acoustic Radiation Force Impulse scores. A Bland-Altman plot was used to evaluate bias between the mean percentage differences of FibroScan® and Acoustic Radiation Force Impulse scores. Univariable and multivariable analyses were used to assess how factors such as body mass index, age and gender influenced the agreement between liver stiffness measurements.

Results: Bland-Altman showed the average (95% CI) percentage difference between FibroScan® and Acoustic Radiation Force Impulse scores was 27.5% (17.8, 37.2), p  < 0.001. There was a negative correlation between the average and percentage difference of the FibroScan® and Acoustic Radiation Force Impulse scores ( r (95% CI) = -0.41 (-0.57, -0.21), p < 0.001), thus showing that percentage difference gets smaller for greater FibroScan® and Acoustic Radiation Force Impulse scores. Body mass index was the biggest influencing factor on differences between FibroScan® and Acoustic Radiation Force Impulse (r = 0.12 (0.01, 0.23), p = 0.05). Acoustic Radiation Force Impulse scores at segment 5/8 and the left lobe showed good correlation (r (95% CI) = 0.83 (0.75, 0.89), p < 0.001).

Conclusion: FibroScan® and Acoustic Radiation Force Impulse had similar predictive values for the assessment of liver stiffness in patients with chronic hepatitis C infection; however, the level of agreement varied across lower and higher scores.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
瞬态弹性成像与声辐射力脉冲弹性成像在评估慢性丙型肝炎患者肝脏健康方面的比较:TRACER 研究的基线结果。
背景:肝脏僵硬度测量可用于评估肝纤维化,可通过使用 FibroScan® 和声学辐射力脉冲成像进行瞬态弹性成像获得。该研究的目的是在慢性丙型肝炎队列中使用 FibroScan® 和 Acoustic Radiation Force Impulse 建立肝脏僵硬度测量评分,并探讨评分之间的相关性和一致性以及影响一致性的因素:患者使用 FibroScan®(肝脏右叶)和 Acoustic Radiation Force Impulse(肝脏左右叶)测量肝脏硬度。我们使用斯皮尔曼相关性来探讨 FibroScan® 和 Acoustic Radiation Force Impulse 分数之间的关系。我们使用 Bland-Altman 图来评估 FibroScan® 和 Acoustic Radiation Force Impulse 评分的平均百分比差异之间的偏差。单变量和多变量分析用于评估体重指数、年龄和性别等因素如何影响肝脏硬度测量结果之间的一致性:Bland-Altman显示,FibroScan®和声学辐射力脉冲评分之间的平均(95% CI)百分比差异为27.5% (17.8, 37.2), p ®和声学辐射力脉冲评分 ( r (95% CI) = -0.41 (-0.57, -0.21), p ®和声学辐射力脉冲评分之间的平均(95% CI)百分比差异为27.5% (17.8, 37.2), p ®和声学辐射力脉冲评分 ( r (95% CI) = -0.41 (-0.57, -0.21), p ®。体重指数是影响 FibroScan® 和 Acoustic Radiation Force Impulse 之间差异的最大因素(r = 0.12 (0.01, 0.23), p = 0.05)。第 5/8 段和左叶的声辐射力脉冲评分显示出良好的相关性(r (95% CI) = 0.83 (0.75, 0.89),p 结论:FibroScan® 和声辐射力脉冲评分之间的相关性较低:FibroScan® 和声学辐射力脉冲对慢性丙型肝炎感染患者肝脏僵硬度的评估具有相似的预测价值;但是,较低和较高分数的一致性水平存在差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Agronomy Journal
Agronomy Journal 农林科学-农艺学
CiteScore
4.70
自引率
9.50%
发文量
265
审稿时长
4.8 months
期刊介绍: After critical review and approval by the editorial board, AJ publishes articles reporting research findings in soil–plant relationships; crop science; soil science; biometry; crop, soil, pasture, and range management; crop, forage, and pasture production and utilization; turfgrass; agroclimatology; agronomic models; integrated pest management; integrated agricultural systems; and various aspects of entomology, weed science, animal science, plant pathology, and agricultural economics as applied to production agriculture. Notes are published about apparatus, observations, and experimental techniques. Observations usually are limited to studies and reports of unrepeatable phenomena or other unique circumstances. Review and interpretation papers are also published, subject to standard review. Contributions to the Forum section deal with current agronomic issues and questions in brief, thought-provoking form. Such papers are reviewed by the editor in consultation with the editorial board.
期刊最新文献
Issue Information Weed management in organic dryland wheat production in the Pacific Northwest Soil health benefits of compost persist two decades after single application to winter wheat Deriving general principles of agroecosystem multifunctionality with the Diverse Rotations Improve Valuable Ecosystem Services (DRIVES) network Multiyear productivity and nitrate-nitrogen loss from corn and prairie bioenergy cropping systems
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1