Using Gold Nanoparticles for Ultra trace Spectrophotometry Determination of Tolyltriazole in Aqueous Media

N. Esmaile, M. Sohrabi, F. Motiee
{"title":"Using Gold Nanoparticles for Ultra trace Spectrophotometry Determination of Tolyltriazole in Aqueous Media","authors":"N. Esmaile, M. Sohrabi, F. Motiee","doi":"10.4172/2379-1764.1000264","DOIUrl":null,"url":null,"abstract":"In this study, the detection limit sensitivity to the level of μg L-1 was achieved. For this, by applying AuNPs signal fluctuations of high sensitivity was carefully monitored so that they become measureable with highest possible precision. The proposed method is capable of determining TTA over a range of 10-100 μgL-1 with a limit of detection 5 μg L-1. The relative standard deviation of the method was 3% and 1.5%. The obtained preliminary results from this study proved to be effectively successful in determination of TTA in water. A comparison between the proposed method and the previously published methods for TTA determination has also been made for the first time.","PeriodicalId":7277,"journal":{"name":"Advanced techniques in biology & medicine","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2018-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advanced techniques in biology & medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4172/2379-1764.1000264","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

In this study, the detection limit sensitivity to the level of μg L-1 was achieved. For this, by applying AuNPs signal fluctuations of high sensitivity was carefully monitored so that they become measureable with highest possible precision. The proposed method is capable of determining TTA over a range of 10-100 μgL-1 with a limit of detection 5 μg L-1. The relative standard deviation of the method was 3% and 1.5%. The obtained preliminary results from this study proved to be effectively successful in determination of TTA in water. A comparison between the proposed method and the previously published methods for TTA determination has also been made for the first time.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
纳米金超痕量分光光度法测定水介质中甲苯三唑
本研究达到了对μg -1水平的检出限灵敏度。为此,通过应用AuNPs,对高灵敏度的信号波动进行了仔细监测,使它们能够以尽可能高的精度进行测量。该方法能在10-100 μ L-1范围内测定TTA,检出限为5 μ L-1。方法的相对标准偏差分别为3%和1.5%。本研究获得的初步结果对水中TTA的测定是有效的。本文还首次将该方法与已有的TTA测定方法进行了比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The Efficiency of Transpiration in Plants Clinical, Laboratory Data and Outcomes of 17 Iranian Citrullinemia Type1 Patients: Identification of Five Novel ASS1 Gene Mutations Mutation Detection via CRISPRCas9 Micro-fluid Chip DNA Extraction by the Utilization of Phenol Chloroform Assessment on CORONA Drugs
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1