New Deformity Outline on the Breast Radiation Therapy for diminishing Absorbed Dose Ratio

A. Khorshidi, M. Ashoor
{"title":"New Deformity Outline on the Breast Radiation Therapy for diminishing Absorbed Dose Ratio","authors":"A. Khorshidi, M. Ashoor","doi":"10.15392/2319-0612.2023.2281","DOIUrl":null,"url":null,"abstract":"Breast cancer is one of the most common malignant diseases in women. After tumor mass surgery, radiation therapy is regularly taken into account the gold standard for the treatment. Kilo to Mega voltage photons have been suggested due to their characteristic depth dose build-up regime, reducing the dose to the breast skin to a fraction of the maximum dose exposure. During treatment, mean glandular dose is commonly used as a criterion for identifying radiation risks. Here, two outlines in cubic-rectangular (CR) and cylindrical- taper (CT) outlines were modelled together with corresponding assumptions using Monte-Carlo simulation and the recorded absorbed dose ratio (ADR) values were compared via defined a positron source by 511 keV energy. The results showed that the amounts of absorption and scattering cross-sections next to the ADR amount decreased as the height of the CR outline decreased. The average dose ratio amount in the CR outline was reduced by about 96% compared to that in the CT outline. By increasing the positron source distance from the nipple, the ADR amounts decreased for both outlines. The amount of accumulated dose ratio decreased harshly in the CR outline rather than in the CT outline. This study can be useful to examine breast tissue deformity in treatment planning.","PeriodicalId":9203,"journal":{"name":"Brazilian Journal of Radiation Sciences","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-07-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Brazilian Journal of Radiation Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15392/2319-0612.2023.2281","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Breast cancer is one of the most common malignant diseases in women. After tumor mass surgery, radiation therapy is regularly taken into account the gold standard for the treatment. Kilo to Mega voltage photons have been suggested due to their characteristic depth dose build-up regime, reducing the dose to the breast skin to a fraction of the maximum dose exposure. During treatment, mean glandular dose is commonly used as a criterion for identifying radiation risks. Here, two outlines in cubic-rectangular (CR) and cylindrical- taper (CT) outlines were modelled together with corresponding assumptions using Monte-Carlo simulation and the recorded absorbed dose ratio (ADR) values were compared via defined a positron source by 511 keV energy. The results showed that the amounts of absorption and scattering cross-sections next to the ADR amount decreased as the height of the CR outline decreased. The average dose ratio amount in the CR outline was reduced by about 96% compared to that in the CT outline. By increasing the positron source distance from the nipple, the ADR amounts decreased for both outlines. The amount of accumulated dose ratio decreased harshly in the CR outline rather than in the CT outline. This study can be useful to examine breast tissue deformity in treatment planning.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
减少吸收剂量比的乳房放射治疗的新畸形大纲
乳腺癌是女性最常见的恶性疾病之一。肿瘤肿块手术后,放射治疗通常被认为是治疗的金标准。千至兆电压光子由于其特有的深度剂量积累机制而被提出,将乳房皮肤的剂量减少到最大剂量暴露的一小部分。在治疗期间,平均腺体剂量通常被用作识别辐射风险的标准。本文采用蒙特卡罗模拟方法,对立方矩形(CR)和圆柱锥形(CT)两种轮廓进行了建模,并进行了相应的假设,并通过511 keV能量的正电子源,比较了记录的吸收剂量比(ADR)值。结果表明,随着CR轮廓高度的降低,ADR量旁边的吸收和散射截面的量减小。CR轮廓图的平均剂量比量较CT轮廓图降低约96%。通过增加正电子源与乳头的距离,两个轮廓的不良反应量都减少了。累积剂量比的量在CR轮廓上明显下降,而在CT轮廓上明显下降。本研究可用于检查乳腺组织畸形的治疗计划。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Análisis integral de visitas guiadas al reactor de investigación nuclear RA-6: perspectivas educativas, de investigación y sociales Development of a sample exchange system for irradiations in the BH-3 channel of the IEA-R1 reactor at IPEN Análise dos índices de exposição de exames de radiografia digital Multiphysics Computational Modeling of Nuclear Reactors Small Size Through the Coupling of Serpent Codes and Fluent Abordagens de blindagens baseadas em polímeros como uma solução prática na redução dos riscos radiológicos em operações de campo
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1